Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
M318 CDMA 1X Mobile Phone Safety Precautions Before using your phone, please read the safety precautions carefully and let your children know these, so that you can use your phone correctly and safely. For details, see " Warnings and Precautions." Do not power on your phone when phone use is prohibited. Do not use your phone while driving. Power off your phone near medical apparatus. Power off your phone in an aircraft. Power off your phone near high-precision electronic devices. Do not attempt to disassemble your phone or its accessories. Do not place your phone or its accessories in containers with strong electromagnetic field. Do not place magnetic storage media near your phone. Do not put your phone in a high-temperature place or use it in a place with flammable gas such as a gas station. Do not allow children to use your phone without guidance. Use approved batteries and chargers only to avoid explosion. Observe the laws or regulations on phone use. Copyright © 2007 Huawei Technologies Co., Ltd. All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and other Huawei trademarks are the trademarks or registered trademarks of Huawei Technologies Co., Ltd. in the People’s Republic of China and certain other countries. All other trademarks mentioned in this manual are the property of their respective holders. Notice The information in this manual is subject to change without notice. Every effort has been made in the preparation of this manual to ensure accuracy of the contents, but all statements, information, and recommendations in this manual do not constitute the warranty of any kind, express or implied. i Table of Contents 1 Getting to Know Your Phone ....................................................... 1 Your Phone............................................................................... 1 Keys and Functions.................................................................. 2 Screen Icons.............................................................................. 3 Interfaces.................................................................................. 5 2 Getting Started............................................................................... 6 Installing the Battery................................................................ 6 Charging the Battery................................................................. 6 Powering On/Off the Phone ..................................................... 7 Using the Function Menu ......................................................... 7 3 Voice Services................................................................................. 9 Making a Call........................................................................... 9 Receiving a Call........................................................................ 9 Options During a Call............................................................. 10 4 Text Entry..................................................................................... 12 Entering English..................................................................... 12 Entering Digits........................................................................ 13 Entering Symbols................................................................... 13 5 Message......................................................................................... 14 Writing and Sending a Message ............................................. 14 Reading a Message................................................................. 15 6 Contacts........................................................................................ 16 Adding a Contact.................................................................... 16 Searching for a Contact.......................................................... 16 ii 7 Alarm Clock................................................................................. 17 Enabling the Alarm Clock...................................................... 17 Disabling the Alarm Clock..................................................... 18 8 Security......................................................................................... 19 Enabling/Disabling the Phone Lock ....................................... 19 Changing the Phone Lock Code............................................. 19 9 Recorder....................................................................................... 20 Recording a Sound Clip.......................................................... 20 Playing a Sound Clip.............................................................. 20 10 TTY Operation .......................................................................... 22 Using the TTY Device............................................................ 22 Setting the TTY Mode ............................................................ 22 11 Menu Commands....................................................................... 23 12 Warnings and Precautions........................................................ 31 1 1 Getting to Know Your Phone Your Phone Earpiece Confirm Key Screen Navigation Keys Left Soft Key Talk/Send Key Number Keys End / Power Key # Key Microphone Right Soft Key Clear Key Key * Charger Interface / Data Cable Connector / Headset Jack 2 Keys and Functions Press... To... z Make a call. z View all calls in the standby mode. z Answer an incoming call. z Power on or off the phone (by pressing and holding it for about two seconds). z End a call. z Return to the home screen. z Display Menu in the standby mode. z Select the highlighted item. z View the @metro in the standby mode. z Return to the previous menu. z Display Menu in the standby mode. z Confirm a selection. z Access: Contacts (), @metro (), MetroWEB ( ), or Messages (); or access Create Message ( ) (by pressing and holding it for about t…
Text truncated - open the document above for the full version.
Huawei Technologies Co., Ltd. Address:Huawei Industrial Base,Bantian Longgang,Shenzhen 518129, P.R China Post ZIP:518129 Page :1/1 To: CETECOM Fax : NULL From:Zhang Xinghai Fax:0086-755-89652518 Tel:0086-755-89651014 Email address: [email protected] Http: www.huawei.com Subject:Letter of Confidentiality Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with the Code of Federal Regulations Title 47 Section 0.457 and 0.459 pertaining to confidential material. Huawei Technologies Co., Ltd. would like the following documents regarding this submission for FCC ID: QISM318to be kept confidential: 1. Schematic diagram & PCB layout. 2. Block Diagram. 3. Parts list (BOM) Information. 4. Operational description. 5. Turn-up procedure The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, For and Behalf of: Huawei Technologies Co., Ltd. Zhang Xinghai EMC Laboratory Manager
Huawei M318 CDMA Handset SECRET Page1,Total 7 External Photo of HUAWEI M318 Huawei M318 CDMA Handset SECRET Page2,Total 7 Huawei M318 CDMA Handset SECRET Page3,Total 7 Huawei M318 CDMA Handset SECRET Page4,Total 7 Huawei M318 CDMA Handset SECRET Page5,Total 7 Huawei M318 CDMA Handset SECRET Page6,Total 7 Huawei M318 CDMA Handset SECRET Page7,Total 7
Huawei M318 CDMA Handset SECRET Page1, Total 1 Label _M318 Label Location_M318
Huawei M318 CDMA Handset SECRET Page1,Total 5 Internal Photo of HUAWEI M318 Huawei M318 CDMA Handset SECRET Page2,Total 5 Huawei M318 CDMA Handset SECRET Page3,Total 5 Huawei M318 CDMA Handset SECRET Page4,Total 5 Huawei M318 CDMA Handset SECRET Page5,Total 5
No. 2007EEE01578 Page 31 of 105 Fig. 8 Z-Scan at power reference point (CDMA 835MHz CH777) No. 2007EEE01578 Page 32 of 105 CDMA 835 MHz Left Tilt Middle Electronics: DAE3 Sn536 Medium: 835 Head Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.928 mho/m; ε r = 40.1; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 800 Frequency: 836.52 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.51, 6.51, 6.51) Tilt Middle/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.077 mW/g Tilt Middle/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.53 V/m; Power Drift = -0.085 dB Peak SAR (extrapolated) = 0.086 W/kg SAR(1 g) = 0.067 mW/g; SAR(10 g) = 0.049 mW/g Maximum value of SAR (measured) = 0.070 mW/g 0 dB = 0.070mW/g Fig. 9 Left Hand Tilt 15°CDMA 835MHz CH384 No. 2007EEE01578 Page 33 of 105 Fig. 10 Z-Scan at power reference point (CDMA 835MHz CH384) No. 2007EEE01578 Page 34 of 105 CDMA 835 MHz Left Tilt Low Electronics: DAE3 Sn536 Medium: 835 Head Medium parameters used (interpolated): f = 824.7 MHz; σ = 0.925 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 800 Frequency: 824.7 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.51, 6.51, 6.51) Tilt Low/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.092 mW/g Tilt Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.96 V/m; Power Drift = -0.188 dB Peak SAR (extrapolated) = 0.102 W/kg SAR(1 g) = 0.082 mW/g; SAR(10 g) = 0.059 mW/g Maximum value of SAR (measured) = 0.090 mW/g 0 dB = 0.090mW/g Fig. 11 Left Hand Tilt 15°CDMA 835MHz CH1013 No. 2007EEE01578 Page 35 of 105 Fig. 12 Z-Scan at power reference point (CDMA 835MHz CH1013) No. 2007EEE01578 Page 36 of 105 CDMA 835 MHz Right Cheek High Electronics: DAE3 Sn536 Medium: 835 Head Medium parameters used (interpolated): f = 848.31 MHz; σ = 0.93 mho/m; ε r = 40; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 800 Frequency: 848.31 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.51, 6.51, 6.51) Cheek High/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.766 mW/g Cheek High/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 7.02 V/m; Power Drift = -0.200 dB Peak SAR (extrapolated) = 0.938 W/kg SAR(1 g) = 0.619 mW/g; SAR(10 g) = 0.383 mW/g Maximum value of SAR (measured) = 0.676 mW/g 0 dB = 0.676mW/g Fig. 13 Right Hand Touch Cheek CDMA 835MHz CH777 No. 2007EEE01578 Page 37 of 105 Fig. 14 Z-Scan at power reference point (CDMA 835MHz CH777) No. 2007EEE01578 Page 38 of 105 CDMA 835 MHz Right Cheek Middle Electronics: DAE3 Sn536 Medium: 835 Head Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.928 mho/m; ε r = 40.1; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 800 Frequency: 836.52 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.51, 6.51, 6.51) Cheek Middle/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.670 mW/g Cheek Middle/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.94 V/m; Power Drift = 0.003 dB Peak SAR (extrapolated) = 0.815 W/kg SAR(1 g) = 0.540 mW/g; SAR(10 g) = 0.337 mW/g Maximum value of SAR (measured) = 0.590 mW/g 0 dB = 0.590mW/g Fig.15 Right Hand Touch Cheek CDMA 835MHz CH384 No. 2007EEE01578 Page 39 of 105 Fig. 16 Z-Scan at power reference point (CDMA 835MHz CH384) No. 2007EEE01578 Page 40 of 105 CDMA 835 MHz Right Cheek Low Electronics: DAE3 Sn536 Medium: 835 Head Medium parameters used (interpolated): f = 824.7 MHz; σ = 0.925 mho/m; ε r = 40.2; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 800 Frequency: 824.7 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.51, 6.51, 6.51) Cheek Low/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.790 mW/g Cheek Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 7.88 V/m; Power Drift = -0.200 dB Peak SAR (extrapolated) = 0.971 W/kg SAR(1 g) = 0.658 mW/g; SAR(10 g) = 0.416 mW/g Maximum value of SAR (measured) = 0.717 mW/g 0 dB = 0.717mW/g Fig. 17 Right Hand Touch Cheek CDMA 835MHz CH1013 No. 2007EEE01578 Page 41 of 105 Fig. 18 Z-Scan at power reference point (CDMA 835MHz CH1013) No. 2007EEE01578 Page 42 of 105 CDMA 835 MHz Right Tilt High Electronics: DAE3 Sn536 Medium: 835 Head Medium parameters used (interpolated): f = 848.31 MHz; σ = 0.93 mho/m; ε r = 40; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 800 Frequency: 848.31 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.51, 6.51, 6.51) Tilt High/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.111 mW/g Tilt High/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.02 V/m; Power Drift = 0.198 dB Peak SAR (extrapolated) = 0.126 W/kg SAR(1 g) = 0.100 mW/g; SAR(10 g) = 0.073 mW/g Maximum value of SAR (measured) = 0.109 mW/g 0 dB = 0.109mW/g Fig. 19 Right Hand Tilt 15°CDMA 835MHz CH777 No. 2007EEE01578 Page 43 of 105 Fig. 20 Z-Scan at power reference point (CDMA 835MHz CH777) No. 2007EEE01578 Page 44 of 105 CDMA 835 MHz Right Tilt Middle Electronics: DAE3 Sn536 Medium: 835 Head Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.928 mho/m; ε r = 40.1; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 800 Frequency: 836.52 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(6.51, 6.51, 6.51) Tilt Middle/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpola…
Text truncated - open the document above for the full version.
No. 2007EEE01578 Page 56 of 105 CDMA 1900 MHz Left Cheek Middle Electronics: DAE3 Sn536 Medium: Head 1900 MHz Medium parameters used: f = 1880 MHz; σ = 1.35 mho/m; ε r = 39.7; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 1900 Frequency: 1880 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(5.4, 5.4, 5.4) Cheek Middle/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.403 mW/g Cheek Middle/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.60 V/m; Power Drift = -0.118 dB Peak SAR (extrapolated) = 0.744 W/kg SAR(1 g) = 0.339 mW/g; SAR(10 g) = 0.173 mW/g Maximum value of SAR (measured) = 0.392 mW/g 0 dB = 0.392mW/g Fig. 33 Left Hand Touch Cheek CDMA 1900MHz CH600 No. 2007EEE01578 Page 57 of 105 Fig. 34 Z-Scan at power reference point (CDMA 1900MHz, CH600) No. 2007EEE01578 Page 58 of 105 CDMA 1900 MHz Left Cheek Low Electronics: DAE3 Sn536 Medium: Head 1900 MHz Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.33 mho/m; ε r = 39.8; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 1900 Frequency: 1851.25 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(5.4, 5.4, 5.4) Cheek Low/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.764 mW/g Cheek Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 8.40 V/m; Power Drift = -0.113 dB Peak SAR (extrapolated) = 0.999 W/kg SAR(1 g) = 0.641 mW/g; SAR(10 g) = 0.327 mW/g Maximum value of SAR (measured) = 0.731 mW/g 0 dB = 0.731mW/g Fig. 35 Left Hand Touch Cheek CDMA 1900MHz CH25 No. 2007EEE01578 Page 59 of 105 Fig. 36 Z-Scan at power reference point (CDMA 1900MHz, CH25) No. 2007EEE01578 Page 60 of 105 CDMA 1900 MHz Left Tilt High Electronics: DAE3 Sn536 Medium: Head 1900 MHz Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.37 mho/m; ε r = 39.6; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 1900 Frequency: 1908.75 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(5.4, 5.4, 5.4) Tilt High/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.137 mW/g Tilt High/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 8.82 V/m; Power Drift = -0.060 dB Peak SAR (extrapolated) = 0.141 W/kg SAR(1 g) = 0.093 mW/g; SAR(10 g) = 0.061 mW/g Maximum value of SAR (measured) = 0.101 mW/g 0 dB = 0.101mW/g Fig. 37 Left Hand Tilt 15° CDMA 1900MHz CH1175 No. 2007EEE01578 Page 61 of 105 Fig. 38 Z-Scan at power reference point (CDMA 1900MHz, CH1175) No. 2007EEE01578 Page 62 of 105 CDMA 1900 MHz Left Tilt Middle Electronics: DAE3 Sn536 Medium: Head 1900 MHz Medium parameters used: f = 1880 MHz; σ = 1.35 mho/m; ε r = 39.7; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 1900 Frequency: 1880 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(5.4, 5.4, 5.4) Tilt Middle/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.130 mW/g Tilt Middle/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 9.48 V/m; Power Drift = -0.064 dB Peak SAR (extrapolated) = 0.155 W/kg SAR(1 g) = 0.108 mW/g; SAR(10 g) = 0.069 mW/g Maximum value of SAR (measured) = 0.119 mW/g 0 dB = 0.119mW/g Fig. 39 Left Hand Tilt 15° CDMA 1900MHz CH600 No. 2007EEE01578 Page 63 of 105 Fig. 40 Z-Scan at power reference point (CDMA 1900MHz, CH600) No. 2007EEE01578 Page 64 of 105 CDMA 1900 MHz Left Tilt Low Electronics: DAE3 Sn536 Medium: Head 1900 MHz Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.33 mho/m; ε r = 39.8; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 1900 Frequency: 1851.25 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(5.4, 5.4, 5.4) Tilt Low/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.204 mW/g Tilt Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 12.1 V/m; Power Drift = 0.037 dB Peak SAR (extrapolated) = 0.290 W/kg SAR(1 g) = 0.184 mW/g; SAR(10 g) = 0.118 mW/g Maximum value of SAR (measured) = 0.198 mW/g 0 dB = 0.198mW/g Fig. 41 Left Hand Tilt 15° CDMA 1900MHz CH25 No. 2007EEE01578 Page 65 of 105 Fig. 42 Z-Scan at power reference point (CDMA 1900MHz, CH25) No. 2007EEE01578 Page 66 of 105 CDMA 1900 MHz Right Cheek High Electronics: DAE3 Sn536 Medium: Head 1900 MHz Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.37 mho/m; ε r = 39.6; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 1900 Frequency: 1908.75 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(5.4, 5.4, 5.4) Cheek High/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.342 mW/g Cheek High/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.57 V/m; Power Drift = -0.200 dB Peak SAR (extrapolated) = 0.533 W/kg SAR(1 g) = 0.301 mW/g; SAR(10 g) = 0.160 mW/g Maximum value of SAR (measured) = 0.333 mW/g 0 dB = 0.333mW/g Fig. 43 Right Hand Touch Cheek CDMA 1900MHz CH1175 No. 2007EEE01578 Page 67 of 105 Fig. 44 Z-Scan at power reference point (CDMA 1900MHz, CH1175) No. 2007EEE01578 Page 68 of 105 CDMA 1900 MHz Right Cheek Middle Electronics: DAE3 Sn536 Medium: Head 1900 MHz Medium parameters used: f = 1880 MHz; σ = 1.35 mho/m; ε r = 39.7; ρ = 1000 kg/m 3 Ambient Temperature:24.5 o C Liqiud Temperature: 24.0 o C Communication System: CDMA 1900 Frequency: 1880 MHz Duty Cycle: 1:1 Probe: ET3DV6 - SN1736 ConvF(5.4, 5.4, 5.4) Cheek Middle/Area Scan (51x121x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (interpolated) = 0.415 mW/g Cheek Middle/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz…
Text truncated - open the document above for the full version.
No. 2007EEE01578 Page 86 of 105 ANNEX E PROBE CALIBRATION CERTIFICATE No. 2007EEE01578 Page 87 of 105 No. 2007EEE01578 Page 88 of 105 No. 2007EEE01578 Page 89 of 105 No. 2007EEE01578 Page 90 of 105 No. 2007EEE01578 Page 91 of 105 No. 2007EEE01578 Page 92 of 105 No. 2007EEE01578 Page 93 of 105 No. 2007EEE01578 Page 94 of 105 No. 2007EEE01578 Page 95 of 105 ANNEX F DIPOLE CALIBRATION CERTIFICATE No. 2007EEE01578 Page 96 of 105 No. 2007EEE01578 Page 97 of 105 No. 2007EEE01578 Page 98 of 105 No. 2007EEE01578 Page 99 of 105 No. 2007EEE01578 Page 100 of 105 No. 2007EEE01578 Page 101 of 105 No. 2007EEE01578 Page 102 of 105 No. 2007EEE01578 Page 103 of 105 No. 2007EEE01578 Page 104 of 105 No. 2007EEE01578 Page 105 of 105
FCC TEST REPORT OF Huawei CDMA Mobile Station M/N: M318 Jun. 04, 2007 Reliability Laboratory of Huawei Technologies Co., Ltd. All Right Reserved Report No: SYBH(R)60052007 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page2, Total39 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Committee for Laboratories (CNAL), and accreditation number: L0310. 2. The laboratory has obtained the accreditation of THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION (A2LA), and Accreditation Council Certificate Number: 2174.01. 3. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 4. The laboratory also has been listed by the VCCI to perform EMC measurements. The accreditation number is C1758, R1672, and T153. 5. The test report is invalid if not marked with "exclusive stamp for the test report". 6. Any copy of the test report is invalid if not re-marked with the "exclusive stamp for the test report". 7. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 8. The test report is invalid if there is any evidence of erasure and/or falsification. 9. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 10. Normally, the test report is only responsible for the samples that have undergone the test. 11. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page3, Total39 REPORT ON FCC Test of Huawei CDMA Mobile Station M/N: M318 Report No: SYBH(R) 60052007 REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 22: Subpart H; FCC CFR47 Part 15: Subpart B; CONCLUSION There are 9 items need to be tested, 9 items have been tested. The sample of the model completely meets the requirements Final Judgement: Pass General Manager 2007.06.06 Guo Xiaoqi Date Name signature Technical Responsibility For Area of Testing 2007.06.06 Zhang Xinghai Date Name signature Test Lab Engineer 2007.06.04 HuJun Huawei Technologies Co Ltd Huawei Industrial Base, Bantian Longgang Shenzhen 518128, P.R China Tel: +86 755 89651014 Fax: +86 755 89652518 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page4, Total39 Contents 1 Summary ..............................................................................................................................................5 2 Product Description...........................................................................................................................6 2.1 PRODUCTION INFORMATION...............................................................................................................6 2.2 MODIFICATION INFORMATION.............................................................................................................6 3 Test Site Description............................................................................................................................7 3.1 TESTING PERIOD..............................................................................................................................7 3.2 GENERAL SET UP DESCRIPTION.........................................................................................................7 4 Product Description .............................................................................................................................8 4.1 TECHNICAL CHARACTERISTICS...........................................................................................................8 4.2 EUT IDENTIFICATION LIST...............................................................................................................10 5 Main Test Instruments........................................................................................................................11 6 Transmitter Measurements.................................................................................................................12 6.1 EFFECTIVE RADIATED POWER OF TRANSMITTER (ERP)......................................................................12 6.2 CONDUCTED OUTPUT POWER..........................................................................................................15 6.3 MODULATION CHARACTERISTICS......................................................................................................17 6.4 OCCUPIED BANDWIDTH...................................................................................................................19 6.5 BAND EDGES COMPLIANCE..............................................................................................................21 6.6 SPURIOUS EMISSION AT ANTENNA TERMINAL.....................................................................................23 6.7 RADIATED SPURIOUS RADIATION......................................................................................................25 6.8 FREQUENCY STABILITY...................................................................................................................29 7 EMC Test ............................................................................................................................................33 7.1 CONDUCTED EMISSION AT POWER PORT..........................................................................................33 7.2 RADIATED EMISSION OF ENCLOSURE IN IDLE MODE.............................................................................36 8 System Measurement Uncertainty.......................................…
Text truncated - open the document above for the full version.
FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page1, Total3 Appendix A Modulation Characteristics According to FCC Part 2.1047 & Part22 Subpart H FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page2, Total3 Cellular band: Channel 283(TM1) Cellular band: Channel 283(TM3) FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page3, Total3 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page1, Total5 Appendix B Occupied Bandwidth According to FCC Part 2.1049 & Part 22 Subpart H FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page2, Total5 Cellular band: Channel 1013(TM1) FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page3, Total5 Cellular band: Channel 1013(TM3) FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page4, Total5 Cellular band: Channel 777(TM1) FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page5, Total5 Cellular band: Channel 777(TM3) FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page1, Total5 Appendix C Band Edges Compliance According to FCC Part 2.1051 & 22.917 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page2, Total5 Cellular band: TM1 Left Edge Channel 1013 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page3, Total5 Right Edge Channel 777 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page4, Total5 Cellular band: TM3 Left Edge Channel 1013 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of HUAWEI. No Distribution without Permission Page5, Total5 Right Edge Channel 777 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page1, Total13 Appendix D Spurious Emission at Antenna Terminal According to FCC Part 2.1051 & 22.917 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page2, Total13 Cellular band: TM1 Channel 1013 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page3, Total13 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page4, Total13 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page5, Total13 Channel 777 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page6, Total13 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page7, Total13 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confidential Information of Huawei. No Distribution without Permission Page8, Total13 Cellular band: TM3 Channel 1013 FCC ID: QISM318 Report No: SYBH (R) 60052007 Confi…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 24E | 1.85 GHz - 1.91 GHz | 142.00 mW | 1M25F9W | 0.02 ppm |

Solar Inverter
Equipment Class
DTS - Digital Transmission System
Watch Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote Radio Unit
Equipment Class
CBD - Citizens Band Category A and B Devices
Indoor Router
Equipment Class
DTS - Digital Transmission System
Solar Smart Monitor & Data Logger
Equipment Class
DTS - Digital Transmission System