Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
For the best experience, open this PDF portfolio in Acrobat 9 or Adobe Reader 9, or later. Get Adobe Reader Now!
Huawei Technologies Co., Ltd. Address:Huawei Industrial Base,Bantian Longgang,Shenzhen 518129, P.R China Post ZIP:518129 Page :1/1 To: CETECOM Fax : NULL From:Zhang Xinghai Fax:0086-755-89652518 Tel:0086-755-89651014 Email address: [email protected] Http: www.huawei.com Subject:Letter of Confidentiality Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with the Code of Federal Regulations Title 47 Section 0.457 and 0.459 pertaining to confidential material. Huawei Technologies Co., Ltd. would like the following documents regarding this submission for FCC ID: QISR205 to be kept confidential: 1. Schematic diagram. 2. Block Diagram. 3. Parts list (BOM) Information. 4. Operational description. 5. Turn-up procedure The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, For and Behalf of: Huawei Technologies Co., Ltd. Zhang Xinghai EMC Laboratory Manager
Huawei Technologies Co., Ltd. Administration Building, Huawei Base, Bantian, Longgang District, Shenzhen 518129 P.R.C. +86 755 28780808 www.huawei.com Huawei internal reference RCT-US-01-01 USA FCC Short Term Confidentiality Request template Effective date: 2007-01-06 Version 1.1 Short Term Confidentiality Request 2011-12-14 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: SHORT-TERM Confidentiality Request for FCC ID: QISR205 Product Name: Vodafone Mobile Wi-Fi Product Model: R205 To whom maybe concern: Pursuant to sections 0.457 and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, Huawei Technologies Co., Ltd requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 45 days: 1. External Photos 2. Internal Photos 3. Test Setup Photos 4. Users Manual The applicant also acknowledges that they will also provide appropriate notice to CETECOM should either of the following occur: A) If the applicant requires additional 45 day extension periods they will notify CETECOM with a new request letter at least 7 days prior to the short-term confidentiality expiration date-[Note: up to maximum of 3 extensions only are allowed], or b) Immediately notify CETECOM in the event the information regarding the product of the product is made available to the public. CETECOM will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely,
Vodafone Mobile Wi-Fi R205 SECRET Page1,Total 9 External Photos of R205 Vodafone Mobile Wi-Fi R205 SECRET Page2,Total 9 1D 1: Vodafone Mobile Wi-Fi R205 SECRET Page3,Total 9 Vodafone Mobile Wi-Fi R205 SECRET Page4,Total 9 Vodafone Mobile Wi-Fi R205 SECRET Page5,Total 9 Vodafone Mobile Wi-Fi R205 SECRET Page6,Total 9 1D 2: Vodafone Mobile Wi-Fi R205 SECRET Page7,Total 9 Vodafone Mobile Wi-Fi R205 SECRET Page8,Total 9 Vodafone Mobile Wi-Fi R205 SECRET Page9,Total 9
Vodafone Mobile Wi-Fi R205 SECRET Page 1 Total 1 ID Label Location_ R205
Vodafone Mobile Wi-Fi R205 SECRET Page1,Total7 Internal Photos of R205 Vodafone Mobile Wi-Fi R205 SECRET Page2,Total7 Vodafone Mobile Wi-Fi R205 SECRET Page3,Total7 Vodafone Mobile Wi-Fi R205 SECRET Page4,Total7 Vodafone Mobile Wi-Fi R205 SECRET Page5,Total7 Vodafone Mobile Wi-Fi R205 SECRET Page6,Total7 Vodafone Mobile Wi-Fi R205 SECRET Page7,Total7
Report No. RZA1112-2004SAR01 Page 1 of 111 TESTING No. L2264 OET 65 TEST REPORT Product Name Vodafone Mobile Wi-Fi Model R205 FCC ID QISR205 Client Huawei Technologies Co., Ltd. TA Technology (Shanghai) Co., Ltd. TA Technology (Shanghai) Co., Ltd. Test Report Report No. RZA1112-2004SAR01 Page 2 of 111 GENERAL SUMMARY Product Name Vodafone Mobile Wi-Fi Model R205 FCC ID QISR205 Report No. RZA1112-2004SAR01 Client Huawei Technologies Co., Ltd. Manufacturer Huawei Technologies Co., Ltd. Reference Standard(s) IEEE Std C95.1, 1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radiofrequency Electromagnetic Fields, 3 kHz to 300 GHz. SUPPLEMENT C Edition 01-01 to OET BULLETIN 65 Edition 97-01 June 2001 including DA 02-1438, published June 2002: Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Additional Information for Evaluation Compliance of Mobile and Portable Devices with FCC Limits for Human Exposure to Radiofrequency Emissions. RSS-102 Issue 4 March 2010: Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) 941225 D01 3G device : SAR Measurement Procedures for 3G Devices– CDMA 2000 / Ev-Do –– WCDMA / HSDPA / HSPA KDB 941225 D06 Hot Spot SAR v01 SAR Evaluation Procedures for Portable Devices with Wireless Router Capabilities Conclusion This portable wireless equipment has been measured in all cases requested by the relevant standards. Test results in Chapter 7 of this test report are below limits specified in the relevant standards. General Judgment: Pass (Stamp) Date of issue: December 9 th , 2011 Comment The test result only responds to the measured sample. Approved by Director Revised by SAR Manager Performed by SAR Engineer TA Technology (Shanghai) Co., Ltd. Test Report Report No. RZA1112-2004SAR01 Page 3 of 111 TABLE OF CONTENT 1. General Information ........................................................................................................................ 5 1.1. Notes of the Test Report.......................................................................................................... 5 1.2. Testing Laboratory ................................................................................................................... 5 1.3. Applicant Information ............................................................................................................... 6 1.4. Manufacturer Information ......................................................................................................... 6 1.5. Information of EUT................................................................................................................... 7 1.6. The Maximum SAR 1g Values ................................................................................................... 9 1.7. Test Date ................................................................................................................................. 9 2. Operational Conditions during Test ............................................................................................... 10 2.1. General Description of Test Procedures................................................................................ 10 2.2. GSM Test Configuration .........................................................................................................10 2.3. WCDMA Test Configuration ................................................................................................... 12 2.4. HSDPA Test Configuration ..................................................................................................... 12 2.5. HSUPA Test Configuration ..................................................................................................... 14 2.6. Test Positions of Portable Devices......................................................................................... 16 3. SAR Measurements System Configuration ................................................................................... 17 3.1. SAR Measurement Set-up .....................................................................................................17 3.2. DASY4 E-field Probe System ................................................................................................ 18 3.2.1. EX3DV4 Probe Specification .......................................................................................... 18 3.2.2. E-field Probe Calibration ................................................................................................. 19 3.3. Other Test Equipment ............................................................................................................19 3.3.1. Device Holder for Transmitters ....................................................................................... 19 3.3.2. Phantom .........................................................................................................................20 3.4. Scanning Procedure ..............................................................................................................20 3.5. Data Storage and Evaluation ................................................................................................. 22 3.5.1. Data Storage...................................................................................................................22 3.5.2. Data Evaluation by SEMCAD ......................................................................................... 22 3.6. System Check........................................................................................................................ 25 3.7. Equivalent Tissues ................................................................................................................. 26 4. Environmental Requirements ........................................................................................................ 27 5. Characteristics of the Test ..................…
Text truncated - open the document above for the full version.
FCC RF Test Report Product Name: Vodafone Mobile Wi-Fi Model Number: R205 Report No: SYBH(Z-RF)003122011-2001 FCC ID:QISR205 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total16 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 3. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-2. 4. The test report is invalid if not marked with "exclusive stamp for the test report". 5. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 6. The test report is invalid if there is any evidence of erasure and/or falsification. 7. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 8. Normally, the test report is only responsible for the samples that have undergone the test. 9. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total16 Applicant: Huawei Technologies Co., Ltd. Address: Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Date of Receipt Test Item: Dec.01, 2011 Start Date of Test: Dec.02, 2011 End Date of Test: Dec.07, 2011 Test Result: Pass Approved By Dec,08. 2011 Dai Linjun Date Name Signature Reviewed By Dec,08. 2011 Cousy Xu Date Name Signature Operator Dec,08. 2011 Huang Qiuliang Date Name Signature FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total16 Contents 1 General Information .................................................................................................................................. 5 1.1 APPLIED STANDARD ............................................................................................................................... 5 1.2 TEST LOCATION ..................................................................................................................................... 5 1.3 TEST ENVIRONMENT CONDITION ............................................................................................................ 5 2 Summary .................................................................................................................................................... 6 3 Product Description .................................................................................................................................. 7 3.1 PRODUCTION INFORMATION ................................................................................................................... 7 3.2 TEST DESCRIPTION ............................................................................................................................... 8 4 General Test Conditions / Configurations ................................................................................................ 9 4.1 RF CHANNELS UNDER TEST ................................................................................................................... 9 4.2 TEST MODES ......................................................................................................................................... 9 4.3 TEST ENVIRONMENTS ............................................................................................................................ 9 4.4 TEST SETUPS ...................................................................................................................................... 10 4.5 TEST CONDITIONS ............................................................................................................................... 12 5 Main Test Instruments ............................................................................................................................. 14 6 Test Results ............................................................................................................................................. 15 7 Measurement Uncertainty ....................................................................................................................... 16 FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page5, Total16 1 General Information 1.1 Applied Standard Applied Rules: 47 CFR FCC Part 2, Subpart J 47 CFR FCC Part 22, Subpart H 1.2 Test Location Test Location 1: Reliability Laboratory of Huawei Technologies Co., Ltd. Address: Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China 1.3 Test Environment Condition Ambient Temperature: 20 – 25 °C Ambient Relative Humidity: 45 – 55 % Atmospheric Pressure: 101 kPa FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2001 Confidential Information of Huawei. No Distribution without Written Permission Page6, Total16 2 Summary Table 1 Summary of results Cellular Band Test Case FCC Part No. Requirements Result Transmitter Output Power 2.1046 & 22.913 ERP not exceed 7 W Pass Modulation Characteristics 2.1047 Digital…
Text truncated - open the document above for the full version.
FCC RF Test Report Product Name: Vodafone Mobile Wi-Fi Model Number: R205 Report No: SYBH(Z-RF)003122011-2002 FCC ID:QISR205 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total16 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 3. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-2. 4. The test report is invalid if not marked with "exclusive stamp for the test report". 5. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 6. The test report is invalid if there is any evidence of erasure and/or falsification. 7. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 8. Normally, the test report is only responsible for the samples that have undergone the test. 9. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total16 Applicant: Huawei Technologies Co., Ltd. Address: Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Date of Receipt Test Item: Dec.01, 2011 Start Date of Test: Dec.02, 2011 End Date of Test: Dec.07, 2011 Test Result: Pass Approved By Dec.08, 2011 Dai Linjun Date Name Signature Reviewed By Dec.08, 2011 Cousy Xu Date Name Signature Operator Dec.08, 2011 Huang Qiuliang Date Name Signature FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total16 Contents 1 General Information .................................................................................................................................. 5 1.1 APPLIED STANDARD ............................................................................................................................... 5 1.2 TEST LOCATION ..................................................................................................................................... 5 1.3 TEST ENVIRONMENT CONDITION ............................................................................................................ 5 2 Test Summary ............................................................................................................................................ 6 3 Product Description .................................................................................................................................. 7 3.1 PRODUCTION INFORMATION ................................................................................................................... 7 3.2 TEST DESCRIPTION ............................................................................................................................... 7 4 General Test Conditions / Configurations ................................................................................................ 9 4.1 RF CHANNELS UNDER TEST ................................................................................................................... 9 4.2 TEST MODES ......................................................................................................................................... 9 4.3 TEST ENVIRONMENTS ............................................................................................................................ 9 4.4 TEST SETUPS ...................................................................................................................................... 10 4.5 TEST CONDITIONS ............................................................................................................................... 12 5 Main Test Instruments ............................................................................................................................. 14 6 Test Results ............................................................................................................................................. 15 7 Measurement Uncertainty ....................................................................................................................... 16 FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page5, Total16 1 General Information 1.1 Applied Standard Applied Rules: 47 CFR FCC Part 2, Subpart J 47 CFR FCC Part 24, Subpart E 1.2 Test Location Test Location 1: Reliability Laboratory of Huawei Technologies Co., Ltd. Address: Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China 1.3 Test Environment Condition Ambient Temperature: 20 – 25 °C Ambient Relative Humidity: 45 – 55 % Atmospheric Pressure: 101 kPa FCC Test Report of R205 FCC ID: QISR205 Report No: SYBH(Z-RF)003122011-2002 Confidential Information of Huawei. No Distribution without Written Permission Page6, Total16 2 Test Summary Table 1 Summary of results PCS Band Test Case FCC Part No. Requirements Result Transmitter Output Power 2.1046 & 24.232 Peak EIRP not exceed 2 W Pass Modulation Characteristics 2.1047 Digi…
Text truncated - open the document above for the full version.
TA Technology (Shanghai) Co., Ltd. Test Report Report No. RZA1112-2004SAR01 Page 107 of 111 ANNEX I: The EUT Appearances and Test Configuration a: EUT TA Technology (Shanghai) Co., Ltd. Test Report Report No. RZA1112-2004SAR01 Page 108 of 111 b: Battery Picture 4: Constituents of the EUT TA Technology (Shanghai) Co., Ltd. Test Report Report No. RZA1112-2004SAR01 Page 109 of 111 Picture 5: Test position 1 Picture 6: Test position 2 10mm 10mm TA Technology (Shanghai) Co., Ltd. Test Report Report No. RZA1112-2004SAR01 Page 110 of 111 Picture 7: Test Position 3 Picture 8: Test Position 4 10mm 10mm TA Technology (Shanghai) Co., Ltd. Test Report Report No. RZA1112-2004SAR01 Page 111 of 111 Picture 9: Test Position 5 Picture 10: Test Position 6 10mm 1 0mm
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 5 | 24E | 1.85 GHz - 1.91 GHz | 504.00 mW | 300KG7W | 19 Hz |

Solar Inverter
Equipment Class
DTS - Digital Transmission System
Watch Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote Radio Unit
Equipment Class
CBD - Citizens Band Category A and B Devices
Indoor Router
Equipment Class
DTS - Digital Transmission System
Solar Smart Monitor & Data Logger
Equipment Class
DTS - Digital Transmission System