Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Feb 05, 2006
Application Purpose
Original Equipment
Date of Application
Feb 05, 2006
Equipment Note
WCDMA Base Station
Frequency Range
1932.50000000 - 1987.50000000
Company
Huawei Technologies Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

HUAWEI NodeB LMT User Guide V100R006 Huawei Technologies Proprietary NodeB LMT User Guide Volume NodeB LMT User Guide Manual Version T2-031640-20051230-C-1.60 Product Version V100R006 BOM 31161640 Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters. Huawei Technologies Co., Ltd. Address: Administration Building, Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, P. R. China Postal Code: 518129 Website: http://www.huawei.com Email: [email protected] Huawei Technologies Proprietary Copyright © 2005 Huawei Technologies Co., Ltd. All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks , HUAWEI, C&C08, EAST8000, HONET, , ViewPoint, INtess, ETS, DMC, TELLIN, InfoLink, Netkey, Quidway, SYNLOCK, Radium, M900/M1800, TELESIGHT, Quidview, Musa, Airbridge, Tellwin, Inmedia, VRP, DOPRA, iTELLIN, HUAWEI OptiX, C&C08 iNET, NETENGINE, OptiX, iSite, U-SYS, iMUSE, OpenEye, Lansway, SmartAX, infoX, TopEng are trademarks of Huawei Technologies Co., Ltd. All other trademarks mentioned in this manual are the property of their respective holders. Notice The information in this manual is subject to change without notice. Every effort has been made in the preparation of this manual to ensure accuracy of the contents, but all statements, information, and recommendations in this manual do not constitute the warranty of any kind, express or implied. Huawei Technologies Proprietary Summary of Updates This section provides the update history of this manual and introduces the contents of subsequent updates. Update History This manual is updated for a major product version to maintain consistency with system hardware or software versions and to incorporate customer suggestions. Manual Version Notes T2-031640-20051230-C-1.60 Initial field trial release Huawei Technologies Proprietary About This Manual Release Notes The product version that corresponds to the manual is WCDMA NodeB V100R006. Organization The manual describes routine maintenance of WCDMA NodeB. There are fourteen chapters and one appendix in the manual. Chapter 1 About This Manual describes general information about this manual. Chapter 2 Overview describes the local maintenance terminal (LMT) system and its elements. Chapter 3 Installing LMT Application describes the installation of LMT software. Chapter 4 Getting Started with LMT describes how to log into the NodeB through the LMT. Chapter 5 Alarm Management describes how to manage the alarms on the NodeB though the LMT. Chapter 6 Managing Files describes how to upload and browse files. Chapter 7 Managing NodeB and Boards describes operations on the NodeB and the boards on the NodeB O&M system. Chapter 8 Tracing NodeB Iub Interface Signaling describes how to create tracing tasks and how to browse traced messages. Chapter 9 Monitoring NodeB Performance and State in Real Time describes how to monitor the NodeB performance and state in real time. Chapter 10 Monitoring External Environment of NodeB describes how to monitor the NodeB external environment. Chapter 11 141 Test describes the NodeB RF performance tests. Chapter 12 Managing NodeB Clock describes routine maintenance of the clock management system. Huawei Technologies Proprietary Chapter 13 Managing NodeB Cells describes operations of the NodeB cell management system. Chapter 14 NodeB Software Update and Data Configuration File Transfer describes the NodeB software upgrade and data configuration file transfer. Appendix A Acronyms and Abbreviations lists all acronyms and abbreviations in this manual with their full names. Intended Audience The manual is intended for the following readers: z Maintenance engineers and technicians Conventions This document uses the following conventions: I. General conventions Convention Description Arial Normal paragraphs are in Arial. Arial Narrow Warnings, cautions, notes and tips are in Arial Narrow. II. Symbols Eye-catching symbols are also used in this document to highlight the points worthy of special attention during the operation. They are defined as follows: Caution, Warning, Danger: Means reader be extremely careful during the operation. Note, Comment, Tip, Knowhow, Thought: Means a complementary description. Huawei Technologies Proprietary NodeB LMT User Guide Table of Contents Table of Contents Chapter 1 About This Manual....................................................................................................... 1-1 1.1 Purpose of This Manual .....................................................................................................1-1 1.2 Intended Audience ............................................................................................................. 1-1 1.3 Architecture of This Manual ............................................................................................... 1-1 Chapter 2 Overview ....................................................................................................................... 2-1 2.1 About This Chapter ............................................................................................................ 2-1 2.2 Introduction to LMT ............................................................................................................ 2-1 2.2.1 Functions of LMT..................................................................................................... 2-1 2.2.2 LMT Configuration Requirements ........................................................................... 2-1 2.3 LMT System Composition.................................................................................................. 2-2 2.3.1 Overview .................................................................................................................2-2 2.3.2 NodeB O&M System .........…

Text truncated - open the document above for the full version.

Users Manual

NodeB LMT User Guide Chapter 8 Tracing NodeB Iub Interface Signaling Chapter 8 Tracing NodeB Iub Interface Signaling 8.1 About This Chapter This chapter describes the Iub interface signaling tracing as follows: z Overview z Creating NodeB Iub Interface Tracing Task z Browsing NodeB Traced Message 8.2 Overview 8.2.1 Principle of Tracing NodeB Iub Interface Signaling The tracing management is used to conduct routine equipment maintenance. The tracing to Iub interfaces and signaling links helps you verify the data and locate the faults. For example, after the equipment data configuration, you can check the signaling links by establishing tracing tasks. If the signaling links are abnormal, you can make preliminary fault location. Table 8-1 shows the procedure of Iub interface signaling tracing. Table 8-1 Procedure of Iub interface signaling tracing Step Action Description Reference 1 Create a tracing task To start the Iub interface tracing See 8.3 "Creating NodeB Iub Interface Tracing Task " 2 Browse traced messages online To display reported traced messages by opening a message browse window after creating a tracing task See 8.4.1 "Browsing NodeB Traced Message " 3 Save traced messages To save important traced messages as required See 8.4.3 "Saving NodeB Traced Messages " and 8.4.4 " Saving NodeB Traced Messages " 4 Stop tracing task To stop the tracing task -- Huawei Technologies Proprietary 8-1 NodeB LMT User Guide Chapter 8 Tracing NodeB Iub Interface Signaling 5 Browse traced messages offline To browse the saved traced messages offline See 8.4.5 "Browsing NodeB Traced Messages " 8.2.2 Introduction to NodeB Iub Interface Tracing The NodeB message tracing refers to the NodeB Iub interface tracing. The Iub interface is a standard open interface between the NodeB and the RNC in the WCDMA system. The Iub interface is used to transmit messages of the user plane, signaling plane and specific O&M. There are two tracing directions: z OUT: from NodeB to RNC (for a macro NodeB, from NMPT to Iub interface boards) z IN: from RNC to NodeB (for a macro NodeB, from Iub interface boards to NMPT) 8.3 Creating NodeB Iub Interface Tracing Task I. Task Introduction Creating an Iub interface tracing task refers to starting the Iub interface tracing. This can trace all the Iub interface messages. After creating a tracing task, the system automatically sends two messages respectively to the master CPU and slave CPU of each available Iub interface board. The aim is to trace messages that the system sends and receives. The maximum message number that the system can send is 4 (number of boards) x 2 (the active and slave CPUs on the board) x 2 (two directions: send and receive) = 16. Note: z Only one Iub interface tracing task can be created in the NodeB O&M system each time, and one message display window can be created for this tracing task. z The prompt for busy system and failure in starting a standard interface tracing task may lie in the overloaded CPU. It is recommended to start the tracing task 30 seconds later when the CPU overloading is cleared. II. Prerequisite None. Huawei Technologies Proprietary 8-2 NodeB LMT User Guide Chapter 8 Tracing NodeB Iub Interface Signaling III. Procedure Follow the steps below to create a tracing task: 1) Choose Maintenance Navigator -> Tracing Management. Then double-click Standard Interface Tracing subnode. A prompt dialog box opens up. Note: You may clear the check box of Show tips at startup next time in the dialog box. This dialog box does not appear when you start a tracing task next time. 2) Click Continue in the dialog box. The Standard Interface Tracing dialog box opens up as shown in Figure 8-1. Figure 8-1 shows the Standard Interface Tracing dialog box. Figure 8-1 Standard Interface Tracing dialog box 3) Click Advanced.... The Advanced dialog box opens up as shown in Figure 8-2. Huawei Technologies Proprietary 8-3 NodeB LMT User Guide Chapter 8 Tracing NodeB Iub Interface Signaling Figure 8-2 Advanced dialog box Table 8-1 describes the fields of the Advanced dialog box. Table 8-2 Field description of Advanced dialog box Field Description Auto Save Select Auto Save. The system saves reported messages in the Trace directory of the running version by default. You may modify the saving directory. Each reported message is to be saved in the message file. Maximum messages per window To set the maximum number of messages displayed in the message browse window Range: 100 to 5000 Default value: 1000 Flow control type Stop Show Message: If the message flow is too large, the system stops displaying messages on the interface. Stop Trace Task: If the message flow is too large, the system stops the tracing task. Message colour To set the display colors of messages in two directions z IN: from RNC to NodeB z OUT: from NodeB to RNC Both directions have 16 optional colors. 4) Set parameters in the Advanced dialog box. 5) Click OK. You are presented with the Standard Interface Tracing window as shown in Figure 8-3. Huawei Technologies Proprietary 8-4 NodeB LMT User Guide Chapter 8 Tracing NodeB Iub Interface Signaling Figure 8-3 shows the Standard Interface Tracing window. Figure 8-3 Standard Interface Tracing window Table 8-3 describes the fields of the Standard Interface Tracing window. Table 8-3 Fields in the Standard Interface Tracing window Field Description Message Sequence No. Sequence number of the message by arrival time Time Message arrival time in the format of YYYY-MM-DD HH:MM:SS Millisecond Traced message reporting interval: 100 ms Message Direction RNC->NodeB: from RNC to NodeB NodeB->RNC: from NodeB to RNC Message Type NBAP messages starting with NBAP_ ALCAP messages starting with ALL2_ Message Content The system translates the message contents displayed in binary into message codes according to the message type. Huawei Technologies Proprietary 8-5 NodeB LMT User Guide Chapter 8 Tracing NodeB Iub Interface Signaling 8.4 Browsing NodeB Traced Message 8.4.1 Browsing …

Text truncated - open the document above for the full version.

Cover Letter(s)

Huawei Technologies Co., Ltd. Address:Huawei Industrial Base,Bantian Longgang,Shenzhen 518128, P.R China Post ZIP:518129 Page :1/1 To: CETECOM Fax : NULL From:Zhang Xinghai Fax:0086-755-89652518 Tel:0086-755-89651014 Email address: [email protected] Http: www.huawei.com Subject:Letter of Confidentiality Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with the Code of Federal Regulations Title 47 Section 0.457 and 0.459 pertaining to confidential material. Huawei Technologies Co., Ltd. would like the following documents regarding this submission for FCC ID: QISRRU3801C-19202 to be kept confidential: 1. Schematic diagram & PCB layout. 2. Block Diagram. 3. Parts list (BOM) Information. 4. Operational description. 5. Tune up procedure The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, For and Behalf of: Huawei Technologies Co., Ltd. Zhang Xinghai EMC Laboratory Manager

Cover Letter(s)

Schmidt, Gerald Von: Generic Office of Engineering Technology [[email protected]] Gesendet: Freitag, 3. Februar 2006 16:29 An: Schmidt, Gerald Betreff: Response to Inquiry to FCC (Tracking Number 264075) Kategorien: FCC 06.02.2006 Inquiry: Dear Sirs, We, Cetecom ICT Services GmbH, are TCB and we have several application for Certification of WCDMA devices (with or without SAR) According to training notes dated October 05, a TCB must request advice from FCC prior to certifying a device. Test cases and configurations have been choosen with good engineering judgment (by using the TCB) and current procedures. Hereby we request additional guidance. Response: Preliminary info document attached - OET/Lab is continuing investigations and developing evaluation procedures and should update this info soon. Please ensure that various applicable device operating modes are properly evaluated. FYI from October 2005 TCB training: - TCBs must request advice from FCC prior to certifying a device, preferably using KDB correspondence - Present advice for CDMA-2000 and UMTS is: TCB should digest preliminary info documents provided by OET/Lab (CDMA-2000 or WCDMA), then perform reviews of tests considering guidelines to best extent possible. TCBs in their review should apply good engineering judgment and present procedures such as Supplement C to the extent applicable. Additional guidance information is under development. Info documents for other technologies ha! ve not been developed at present. - When unsure how to address a particular point in their review, TCB should again contact OET/Lab for specific advice - Request-for-info correspondence and FCC response should be included as EAS cover-letter exhibit in the filing, to demonstrate that TCB has requested and reviewed info prior to certification. For other questions on this specific matter, please use "Reply to an Inquiry Response" (https://gullfoss2.fcc.gov/prod/oet/cf/kdb/forms/ResponseReplyEntry . or for different topics "Submit An Inquiry" (https://gullfoss2.fcc.gov/prod/oet/cf/kdb/forms/InquiryForm.cfm ) Do not reply to ! this mes sage. Please select the Reply to an Inquiry Response link from the OET Inquiry S ystem to add any additional information pertaining to this inquiry.

External Photos

HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page1,Total 6 Photo documentation of External of product HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page2,Total 6 HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page3,Total 6 HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page4,Total 6 HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page5,Total 6 VSWRTX_ACT ALM RUN TST_RSLT CPRI_E CPRI_W Maintenance cavity TST_ANT TST_CPRI RST ETH/RS232 LOCAT_ID 3 1 3 2 PWR RX-IN/OUT ANT-TX/RXA ANT_RXB Module bottom 1 ALD EXT_ALM/ FAN Cabling cavity 2 OFF ON ON4 3 2 1 CPRI_E CPRI_W HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page6,Total 6 (1) (2) (4) (3) (1) Attachment plate (2) M6 x 12 screw (3) Hook (4) RRU3801C module Mounting attachment plate on RRU3801C module

Internal Photos

HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page1,Total 6 Photo documentation of interior of product HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page2,Total 6 HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page3,Total 6 HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page4,Total 6 HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page5,Total 6 HUAWEI RRU3801C WCDMA base station SECRET 1/26/2006 Page6,Total 6

RF Exposure Info

A.1 Introduction Base Transceiver Station (BTS) emit RF radiation (Radiation Hazard). Although there is no scientific evidence of possible health risks to persons living near to base stations some recommendations are giving below for the installation and operation of base station transceivers. Operators of base station transceivers are required to obey the local regulation for erecting base station transceivers. The Federal Communications Commission (FCC), are imposing MPE (maximum permissible exposure) limits. FCC CFR part 1, subpart I, section 1.1307 requires operator to perform a Environmental Assessment (EA). Equipment listed in the table 1 of before mentioned part is subjected to routine environmental evaluation. For facilities and operations licensed under part 24, licensees and manufacturer are required to ensure that their facility and equipment comply with IEEE C95.1-1999. The objective of the Environmental Evaluation is to ensure that human exposure to RF energy does not go beyond the maximum permissible levels stated in the standard. Therefore certain sites do not require an evaluation by nature of its design. It could be that the antennas are placed high enough thereby resulting in extremely low RF fields by the time it reaches areas that would be accessible to people. Environmental evaluations are required, for Personal Communication Services, Part 24: Broadband PCS (Subpart E) if: ‰ Non-building mounted antennas: height of radiation center < 10m above ground level and total power of all channels > 2000 W ERP (3280 W EIRP) ‰ Building-mounted antennas: total power of all channels > 2000 W ERP (3280 W EIRP) A.2 Maximum Permissible Exposure (MPE) Maximum permissible exposure (MPE) refers to the RF energy that is acceptable for human exposure, given the scientific research to date. It is broken down into two categories, Controlled and Uncontrolled. Controlled limits are used for persons such as installers and designers that are in control of the hazard and exposed to energy for limited amounts of time per day. Occupational/controlled limits apply in situations in which are persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where ccupational/controlled limits apply provided he or she is made aware of the potential for exposure. Uncontrolled limits are used for general public. General population/uncontrolled exposure apply in situations is which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or can not exercise control over their exposure. The exposure levels can be expressed in terms of power density, electric field strength, or magnetic field strength, as averaged over 30 minutes for the general public and 6 minutes for trained personnel. The exposure criterion is frequency dependent, and a chart covering the range from 3 kHz to 100 GHz can be found in NCRP No.86 (references IEEE C95.1-1991). Below are the limits. Limits for Occupational/Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) 0.3-3.0 3.0-30 30-300 300-1500 1500-100,000 614 1842/f 61.4 -- -- .63 4.89/f 0.163 -- -- (100)* (900/f 2 )* 1.0 f/300 5 Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) 0.3-3.0 3.0-30 30-300 300-1500 1500-100,000 614 842/f 27.5 -- -- 1.63 2.19/f 0.073 -- -- (100)* (180/f 2 )* 0.2 f/1500 1.0 Power density S [mW/cm 2 ] for controlled area at 1960 MHz 2 /5cmmWS= Power density S [mW/cm 2 ] for uncontrolled area at 1960 MHz 2 /1cmmWS= A.3 Calculation of the Safe Distance Calculations can be made on a site by site basis to ensure the power density is below the limits given above, or guidelines can be done beforehand to ensure the minimum distances from the antenna is maintained through the site planning. The calculations are based on FCC OET 65 Appendix B. A.4 Prediction of the Exposure to Electromagnetic Fields Below method describes a theoretical approach to calculate possible exposure to electromagnetic radiation around a base station transceiver antenna. Precise statements are basically only possible either with measurements or complex calculations considering the complexity of the environment (e.g. soil conditions, near buildings and other obstacles) which causes reflections, scattering of electromagnetic fields. The maximum output power (given in EIRP) of a base station is usually limited by license conditions of the network operator. A rough estimation of the expected exposure in power flux density on a given point can be made with the following equation. The calculations are based on FCC OET 65 Appendix B. π∗∗ ∗ = )(4 )( 2 mr GWP S numeric Whereas: P = Maximum output power in W of the site G numeric = Numeric gain of the antenna relative to isotropic antenna R = distance between the antenna and the point of exposure in meters A.5 Calculation of the Safe Distance Calculations can be made on a site by site basis to ensure the power density is below the limits given above, or guidelines can be done before hand to ensure the minimum distances from the antenna is maintained through the site planning. S PtG r d π4 **64.1 = Whereas: r = distance from the antenna [m] d G= Antenna gain relative to half wave dipole Pt = Power at the antenna terminals [W] S = power density [W/m 2 ] see also MPE Limits Note: 1mW/cm 2 = 10W/m 2 For below calculation the worst case is considered.The antenna consists of a strong directional characteristic. S PtG r numeric π4 * = It is important to note that reflections from the ground and nearby fences increase power de…

Text truncated - open the document above for the full version.

Test Report

FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page1, Total13 Appendix A Channel Power Measurement According to CFR 47 (FCC) part 2.1046 & 24.232 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page2, Total13 Single Carrier DC -48V supply Channel 412 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page3, Total13 Channel 537 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page4, Total13 Channel 687 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page5, Total13 Double Carriers DC -48V supply Channel 537/Channel 562 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page6, Total13 Channel 537/Channel 562 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page7, Total13 Channel 537/Channel 562 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page8, Total13 Single Carriers AC 220V supply Channel 412 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page9, Total13 Channel 537 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page10, Total13 Channel 687 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page11, Total13 Double carriers AC 220V supply Channel 537/Channel 562 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page12, Total13 Channel 537/Channel 562 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page13, Total13 Channel 537/Channel 562 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page1, Total5 Appendix B Modulation Characteristic Measurement According to CFR 47 (FCC) part 2.1047 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page2, Total5 Single Carrier DC -48v supply Channel 537 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page3, Total5 Channel 537 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page4, Total5 Single carrier AC 220v supply Channel 537 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page5, Total5 Channel 537 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page1, Total13 Appendix C Occupied Bandwidth Measurement According to CFR 47 (FCC) part 2.1049 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page2, Total13 Single carrier DC -48V supply Channel 412 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page3, Total13 Channel 537 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page4, Total13 Channel 687 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page5, Total13 Channel 412 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page6, Total13 Channel 537 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page7, Total13 Channel 687 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page8, Total13 Single carrier AC 220V supply Channel 412 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page9, Total13 Channel 537 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page10, Total13 Channel 687 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page11, Total13 Channel 412 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page12, Total13 Channel 537 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page13, Total13 Channel 687 TM5 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page1, Total17 Appendix D Band Edge Compliance According to CFR 47 (FCC) part 2.1051 & 24.238 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page2, Total17 1 Measurement Results at Band Edges Single Carrier DC -48v supply Channel 412 TM1 FCC ID: QISRRU3801C-19202 Report No: CSBG (R)56122005EB Confidential Information of Huawei. No Distribution without Permission Page3, To…

Text truncated - open the document above for the full version.

Test Report

Report No: CSBG (R) 56122005EB FCC ID: QISRRU3801C-19202 FCC TEST REPORT OF HUAWEI WCDMA Base Station M/N: RRU3801C JAN. 16, 2006 Reliability Laboratory of Huawei Technologies Co., Ltd. All Right Reserved Report No: CSBG (R)56122005 Confidential Information of Huawei. No Distribution without Permission Page2, Total55 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Committee for Laboratories (CNAL), and accreditation number: L0310. 2. The laboratory has obtained the accreditation of THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION (A2LA), and Accreditation Council Certificate Number: 2174.01. 3. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 4. The laboratory also has been listed by the VCCI to perform EMC measurements. The accreditation number is C1758, R1672, and T153. 5. The test report is invalid if not marked with "exclusive stamp for the test report". 6. Any copy of the test report is invalid if not re-marked with the "exclusive stamp for the test report". 7. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 8. The test report is invalid if there is any evidence of erasure and/or falsification. 9…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Zhang Xinghai
[email protected]+86-755-2897-0299Fax: +86-755-8965-0226

Test Firm

Huawei Technologies Co., LTDZhou Fengyum
[email protected]86-755-28782917Fax: 86-755-89650226

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.93 GHz - 1.99 GHz22.2 W5M00F9W23.0000000000 Hz
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna used for this transmitter must be fixed-mounted on outdoor permanent structures and RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau, including co-location requirements of 1.1307(b)(3).

Other Applications from Huawei Technologies Co.,Ltd

Solar Inverter - FCC ID QISSUN2000 - Huawei Technologies Co.,Ltd
QISSUN2000

Solar Inverter

Jun 27, 2021

Equipment Class

DTS - Digital Transmission System
Watch Wireless Charger - FCC ID QISCP81-1 - Huawei Technologies Co.,Ltd
QISCP81-1

Watch Wireless Charger

Oct 22, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote Radio Unit - FCC ID QISRRU3278 - Huawei Technologies Co.,Ltd
QISRRU3278

Remote Radio Unit

Sep 02, 2020

Equipment Class

CBD - Citizens Band Category A and B Devices
Indoor Router - FCC ID QISR2561 - Huawei Technologies Co.,Ltd
QISR2561

Indoor Router

Jul 11, 2020

Equipment Class

DTS - Digital Transmission System
Solar Smart Monitor & Data Logger - FCC ID QISSMARTLOGGER310 - Huawei Technologies Co.,Ltd
QISSMARTLOGGER310

Solar Smart Monitor & Data Logger

Mar 23, 2020

Equipment Class

DTS - Digital Transmission System