FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Huawei Technologies Co.,Ltd/
  3. QISU3100-5

QISU3100-5WCDMA/GPRS/GSM Mobile Phone with Bluetooth

Huawei Technologies Co.,Ltd
WCDMA/GPRS/GSM Mobile Phone with Bluetooth - FCC ID QISU3100-5 - Huawei Technologies Co.,Ltd
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Feb 11, 2010
Application Purpose
Original Equipment
Date of Application
Feb 11, 2010
Equipment Note
WCDMA/GPRS/GSM Mobile Phone with Bluetooth
Frequency Range
1852.40000000 - 1907.60000000
Company
Huawei Technologies Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wonderful Communication, Mobile life. HUAWEI U3100-5/U3100-5 Mobile Phone User Guide Copyright © 2010 Huawei Technologies Co., Ltd. All Rights Reserved No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. The product described in this manual may include copyrighted software of Huawei Technologies Co., Ltd and possible licensors. Customers shall not in any manner reproduce, distribute, modify, decompile, disassemble, decrypt, extract, reverse engineer, lease, assign, or sublicense the said software, unless such restrictions are prohibited by applicable laws or such actions are approved by respective copyright holders under licenses. Trademarks and Permission , HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd. Other product, service and company names mentioned are the property of their respective owners. Notice Some features of the product and its accessories described herein rely on the software installed, capacities and settings of local network, and may not be activated or may be limited by local network operators or network service providers, thus the descriptions herein may not exactly match the product or its accessories you purchase. Huawei Technologies Co., Ltd reserves the right to change or modify any information or specifications contained in this manual without prior notice or obligation. NO WARRANTY THE CONTENTS OF THIS MANUAL ARE PROVIDED “AS IS”. EXCEPT AS REQUIRED BY APPLICABLE LAWS, NO WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE MADE IN RELATION TO THE ACCURACY, RELIABILITY OR CONTENTS OF THIS MANUAL. TO THE MAXIMUM EXTENT PERMITTED BY APPLI- CABLE LAW, IN NO CASE SHALL HUAWEI TECHNOLO- GIES CO., LTD BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, OR LOST PROFITS, BUSINESS, REVENUE, DATA, GOODWILL OR ANTICIPATED SAVINGS. Import and Export Regulations Customers shall comply with all applicable export or import laws and regulations and will obtain all necessary governmental permits and licenses in order to export, re-export or import the product mentioned in this manual including the software and technical data therein. Safety Precautions Please read the safety precautions carefully to ensure the correct and safe use of your wireless device. For detailed infor- mation, refer to the section “Warnings and Precautions”. Do not switch on your phone when it is prohibited to use mobile phones or when the phone may cause interference or danger. Switch off your phone near high-precision electronic devices. The phone may affect the performance of these devices. Do not use your phone while driving. Do not attempt to disassemble your phone or its accessories. Only qualified personnel are allowed to service or repair the phone. Follow any rules or regulations in hospitals and health care facilities. Switch off your phone near medical apparatus. Do not place your phone or its accessories in containers with strong electromagnetic field. Switch off your phone in aircraft. The phone may cause interference to control signals of the aircraft. Do not place magnetic storage media near your phone. Radiation from the phone may erase the information stored on them. Do not put your phone in a high-temperature place or use it in a place with flammable gas such as a gas station. Observe any laws or regulations on the use of wireless device. Respect others’ privacy and legal rights when using your wireless device. Keep your phone and its accessories away from children. Do not allow children to use your phone without guidance. Strictly follow the relevant instructions of this manual while using the USB cable. Otherwise your phone or PC may be damaged. Use only approved batteries and chargers to avoid the risk of explosions. 1.Introduction Packing List . . . . . . . . . . 1 Your Phone . . . . . . . . . . 2 Swaper . . . . . . . . . . . . . 6 Security . . . . . . . . . . . . . 7 Text Input . . . . . . . . . . . 8 2.Customized Settings Phone Settings . . . . . . 10 Display Settings . . . . . 10 Network Settings . . . . . 11 3.Call Function Managing Contacts . . . 12 Viewing the Call Records . . . . . . . . . . . . . . . . . . . 13 Making or Ending a Cal l . . . . . . . . . . . . . . . . . . 13 Answering or Rejecting a Call . . . . . . . . . . . . . . . 13 4.Message Function Message . . . . . . . . . . . 15 Email . . . . . . . . . . . . . . 16 5.Connection Function Connectivity Settings . . 18 USB . . . . . . . . . . . . . . . 18 Bluetooth ® . . . . . . . . . . 20 6.Entertainment Function Music . . . . . . . . . . . . . 23 Camera . . . . . . . . . . . . 23 Browser . . . . . . . . . . . . 24 7.Business Function Calendar Management 25 File Management . . . . 25 8.Warnings and Precautions Electronic Device . . . . 28 Medical Device . . . . . . 28 Potentially Explosive Atmospheres . . . . . . . . 28 Traffic Security . . . . . . 29 Operating Environment 30 Preventing Hearing Damage . . . . . . . . . . . 31 Safety of Children . . . . 31 Accessories . . . . . . . . 31 Battery and Charger . . 31 Clearing and Maintenance 32 Emergency Call . . . . . 33 Certification Information (SAR) . . . . . . . . . . . . . 34 FCC Statement . . . . . . 34 Disposal and Recycling Information . . . . . . . . . 35 Reduction of Hazardous Contents Substances . . . . . . . . . 36 EU regulatory conformance . . . . . . . . 36 1 1. Introduction Your Phone can operate in virtually all countries, automatically switching between WCDMA 850/1900 and GSM/GPRS 850/1800/1900 networks. NOTE: The services supported by your phone should be also supported by the network from where you use the phone. For details, contact your service provider. Packing List Your phone package box contains the following: 1.One mobile phone 2.One travel charger 3.One Li-ion battery 4.One User Guide 5…

Text truncated - open the document above for the full version.

Cover Letter(s)

Huawei Technologies Co., Ltd. Address:Huawei Industrial Base,Bantian Longgang,Shenzhen 518129, P.R China Post ZIP:518129 Page :1/1 To: CETECOM Fax : NULL From:Zhang Xinghai Fax:0086-755-89652518 Tel:0086-755-89651014 Email address: [email protected] Http: www.huawei.com Subject:Letter of Confidentiality Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with the Code of Federal Regulations Title 47 Section 0.457 and 0.459 pertaining to confidential material. Huawei Technologies Co., Ltd. would like the following documents regarding this submission for FCC ID: QISU3100-5 to be kept confidential: 1. Schematic diagram. 2. Block Diagram. 3. Parts list (BOM) Information. 4. Operational description. 5. Tune-up procedure The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, For and Behalf of: Huawei Technologies Co., Ltd. Zhang Xinghai EMC Laboratory Manager

External Photos

HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page1,Total 7 External Photos of HUAWEI U3100-5/U3100-5 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page2,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page3,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page4,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page5,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page6,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page7,Total 7

ID Label/Location Info

HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page 1, Total 3 Label Location HUAWEI U3100-5/U3100-5 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page 2, Total 3 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page 3, Total 3

ID Label/Location Info

HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page1, Total 1 ID Label HUAWEI U3100-5/U3100-5

Internal Photos

HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page1,Total 7 Internal Photos of HUAWEI U3100-5/U3100-5 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page2,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page3,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page4,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page5,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page6,Total 7 HUAWEI U3100-5/U3100-5 WCDMA/GPRS/GSM Mobile Phone with Bluetooth SECRET Page7,Total 7

RF Exposure Info

Huawei Technologies Co.,Ltd. Huawei Base, Bantian, Longgang District, Shenzhen, P.R.China Phone: +86-755-28785278 SAR-Laboratory Fax: +86-755-36834474 . Report On SAR Test of WCDMA/GPRS/GSM Mobile Phone with Bluetooth M/N: HUAWEI U3100-5/U3100-5 Test report no. : SYBH(Z-SAR)212012010 Type identification : HUAWEI U3100-5/U3100-5 FCC-ID : QISU3100-5 Test specification : IEEE 1528-2003 : ANSI C95.1-1999 : RSS-102 issue 2 (2005) : OET Bulletin 65 Supplement C : IEC 62209-2:2008(106/162/CDV) Accredited testing laboratory CNAS Registration number: L0310 Huawei Technologies Co.,Ltd. Test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 2 of 122 Table of Contents 1 General Information............................................................................................................................................................... 3 1.1 Notes ............................................................................................................................................................................. 3 1.1.1 Statement of Compliance .......................................................................................................................................... 3 1.2 Testing laboratory ......................................................................................................................................................... 4 1.3 Details of applicant ....................................................................................................................................................... 4 1.4 Application details ........................................................................................................................................................ 4 1.5 Test item ....................................................................................................................................................................... 5 1.5.1 EUT Description ....................................................................................................................................................... 6 1.6 Test specification(s) ...................................................................................................................................................... 6 1.6.1 RF exposure limits .................................................................................................................................................... 6 2 Technical test ......................................................................................................................................................................... 8 2.1 Summary of test results................................................................................................................................................. 8 2.2 Test environment .......................................................................................................................................................... 8 2.3 Measurement and test set-up......................................................................................................................................... 8 2.4 Measurement system..................................................................................................................................................... 9 2.4.1 System Description ................................................................................................................................................... 9 2.4.2 Test environment .................................................................................................................................................... 10 2.4.3 Probe description .................................................................................................................................................... 10 2.4.4 Phantom description ............................................................................................................................................... 12 2.4.5 Device holder description ....................................................................................................................................... 12 2.4.6 Scanning procedure................................................................................................................................................. 13 2.4.7 Spatial Peak SAR Evaluation.................................................................................................................................. 14 2.4.8 Data Storage and Evaluation................................................................................................................................... 15 2.4.9 Test equipment utilized........................................................................................................................................... 17 2.4.10 Tissue simulating liquids: dielectric properties .................................................................................................. 18 2.4.11 Tissue simulating liquids: parameters................................................................................................................. 19 2.4.12 Measurement uncertainty evaluation for SAR test ............................................................................................. 20 2.4.13 Measurement uncertainty evaluation for system validation................................................................................ 21 2.4.14 System validation ............................................................................................................................................... 22 2.4.15 Validation procedure .......................................................................................................................................... 23 2.5 Test Results ............................................................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Huawei Technologies Co.,Ltd. Huawei Base, Bantian, Longgang District, Shenzhen, P.R.China Phone: +86-755-28785278 SAR-Laboratory Fax: +86-755-36834474 . Page 1 of 35 Accredited testing laboratory CNAS Registration number: L0310 Appendix to test report no. SYBH(Z-SAR)212012010 Calibration data, Phantom certificate and detail information of the DASY5 System Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 2 of 35 Table of Content 1 Calibration report “Probe ES3DV3” ..................................................................................................................................... 3 2 Calibration report “1900 MHz System validation dipole”................................................................................................... 11 3 Calibration report “835 MHz System validation dipole”..................................................................................................... 18 4 Calibration certificate of Data Acquisition Unit (DAE) ...................................................................................................... 25 5 Application Note System Performance Check .................................................................................................................... 30 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 3 of 35 1 Calibration report “Probe ES3DV3” Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 4 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 5 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 6 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 7 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 8 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 9 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 10 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 11 of 35 2 Calibration report “1900 MHz System validation dipole” Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 12 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 13 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 14 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 15 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 16 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 17 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 18 of 35 3 Calibration report “835 MHz System validation dipole” Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 19 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 20 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 21 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 22 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 23 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 24 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 25 of 35 4 Calibration certificate of Data Acquisition Unit (DAE) Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 26 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 27 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 28 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 29 of 35 Huawei Technologies Co.,Ltd. Calibration Data and Phantom Information to test report no.: SYBH(Z-SAR)212012010 As of 2010-01-29 Page 30 of 35 5 Application Note System Performance Check 5.1.1.1 Purpose of system performance check The system performance check verifies that the system operates within its specifications. System and operator errors can be detected and corrected. It is recommended that the system performance check is performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the result depends on the proper …

Text truncated - open the document above for the full version.

Test Report

Zur optimalen Anzeige dieses PDF-Portfolios sollte es in Acrobat oder Adobe Reader ab Version 9 geöffnet werden. Adobe Reader jetzt herunterladen

Test Report

FCC Test Report Product Name: WCDMA/GPRS/GSM Mobile Phone with Bluetooth Model Number: HUAWEI U3100-5/U3100-5 Report No: SYBHZ(R)E011022010EB-2 FCC ID: QISU3100-5 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of HUAWEI U3100-5/U3100-5 FCC ID: QISU3100-5 Security Level: Public Report No: SYBHZ(R)E011022010EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total32 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has obtained the accreditation of THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION (A2LA), and Accreditation Council Certificate Number: 2174.01. 3. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 4. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-1. 5. The laboratory also has been listed by the VCCI to perform EMC measurements. The accreditation number is R2364, C2583, and T256. 6. The test report is invalid if not marked with "exclusive stamp for the test report". 7. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 8. The test report is invalid if there is any evidence of erasure and/or falsification. 9. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 10. Normally, the test report is only responsible for the samples that have undergone the test. 11. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of HUAWEI U3100-5/U3100-5 FCC ID: QISU3100-5 Security Level: Public REPORT ON FCC Test of WCDMA/GPRS/GSM Mobile Phone with Bluetooth M/N: HUAWEI U3100-5/U3100-5 Report No: SYBHZ(R)E011022010EB-2 FCC ID: QISU3100-5 REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 22: Subpart H; CONCLUSION PASS General Manager 2010.2.1 Date Name signature Technical Responsibility For Area of Testing 2010.2.1 Date Name signature Test Lab Engineer 2010.2.1 Date Name signature Report No: SYBHZ(R)E011022010EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total32 FCC Test Report of HUAWEI U3100-5/U3100-5 FCC ID: QISU3100-5 Security Level: Public Report No: SYBHZ(R)E011022010EB-2 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total32 Contents 1 Summary.................................................................................................................................................... 5 2 Product Description.................................................................................................................................. 6 2.1 PRODUCTION INFORMATION................................................................................................................... 6 2.2 MODIFICATION INFORMATION.................................................................................................................. 6 3 Test Site Description................................................................................................................................. 7 3.1 TESTING PERIOD................................................................................................................................... 7 3.2 GENERAL SET UP DESCRIPTION............................................................................................................. 7 4 Product Description.................................................................................................................................. 8 4.1 TECHNICAL CHARACTERISTICS............................................................................................................... 8 4.2 EUT IDENTIFICATION LIST.................................................................................................................... 10 5 Main Test Instruments............................................................................................................................. 12 6 Transmitter Measurements..................................................................................................................... 13 6.1 EFFECTIVE RADIATED POWER OF TRANSMITTER (ERP)......................................................................... 13 6.2 CONDUCTED POWER OF TRANSMITTER................................................................................................. 17 6.3 MODULATION CHARACTERISTICS.......................................................................................................... 19 6.4 OCCUPIED BANDWIDTH........................................................................................................................ 21 6.5 BAND EDGES COMPLIANCE.................................................................................................................. 24 6.6 SPURIOUS EMISSION AT ANTENNA TERMINAL........................................................................................ 26 6.7 FREQUENCY STABILITY........................................................................................................................ 28 7 System Measurement Uncertainty......................................................................................................... 31 8 Appendices.............................................................................................................................................. 32 FCC Tes…

Text truncated - open the document above for the full version.

Test Report

FCC Test Report Product Name: WCDMA/GPRS/GSM Mobile Phone with Bluetooth Model Number: HUAWEI U3100-5/U3100-5 Report No: SYBHZ(R)E011022010EB-3 FCC ID: QISU3100-5 Reliability Laboratory of Huawei Technologies Co., Ltd. Huawei Base, Bantian, Longgang District, Shenzhen 518129, P.R. China Tel: +86 755 28780808 Fax: +86 755 89652518 FCC Test Report of HUAWEI U3100-5/U3100-5 FCC ID: QISU3100-5 Security Level: Public Report No: SYBHZ(R)E011022010EB-3 Confidential Information of Huawei. No Distribution without Written Permission Page2, Total32 Notice 1. The laboratory has obtained the accreditation of China National Accreditation Service for Conformity Assessment (CNAS), and accreditation number: L0310. 2. The laboratory has obtained the accreditation of THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION (A2LA), and Accreditation Council Certificate Number: 2174.01. 3. The laboratory has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements. The site recognition number is 97456. 4. The laboratory has been listed by industry Canada to perform electromagnetic emission measurement. The site recognition number is 6369A-1. 5. The laboratory also has been listed by the VCCI to perform EMC measurements. The accreditation number is R2364, C2583, and T256. 6. The test report is invalid if not marked with "exclusive stamp for the test report". 7. The test report is invalid if not marked with the stamps or the signatures of the persons responsible for performing, revising and approving the test report. 8. The test report is invalid if there is any evidence of erasure and/or falsification. 9. If there is any dissidence for the test report, please file objection to the test centre within 15 days from the date of receiving the test report. 10. Normally, the test report is only responsible for the samples that have undergone the test. 11. Context of the test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of the laboratory. FCC Test Report of HUAWEI U3100-5/U3100-5 FCC ID: QISU3100-5 Security Level: Public REPORT ON FCC Test of WCDMA/GPRS/GSM Mobile Phone with Bluetooth M/N: HUAWEI U3100-5/U3100-5 Report No: SYBHZ(R)E011022010EB-3 FCC ID: QISU3100-5 REGULATION FCC CFR47 Part 2: Subpart J; FCC CFR47 Part 24: Subpart E; CONCLUSION PASS General Manager 2010.2.1 Date Name signature Technical Responsibility For Area of Testing 2010.2.1 Date Name signature Test Lab Engineer 2010.2.1 Date Name signature Report No: SYBHZ(R)E011022010EB-3 Confidential Information of Huawei. No Distribution without Written Permission Page3, Total32 FCC Test Report of HUAWEI U3100-5/U3100-5 FCC ID: QISU3100-5 Security Level: Public Report No: SYBHZ(R)E011022010EB-3 Confidential Information of Huawei. No Distribution without Written Permission Page4, Total32 Contents 1 Summary............................................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Zhang Xinghai
[email protected]+86-755-2897-0299Fax: +86-755-8965-0226

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
424E1.85 GHz - 1.91 GHz310.00 mW4M20F9W0.01 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is ERP for Part 22 and EIRP for Part 24. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 15 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR values are: Part 24: Head: 1.09 W/kg, Body:0.583 W/kg ; Part 22: Head: 0.745 W/kg, Body: 0.813 W/kg

Other Applications from Huawei Technologies Co.,Ltd

Solar Inverter - FCC ID QISSUN2000 - Huawei Technologies Co.,Ltd
QISSUN2000

Solar Inverter

Jun 27, 2021

Equipment Class

DTS - Digital Transmission System
Watch Wireless Charger - FCC ID QISCP81-1 - Huawei Technologies Co.,Ltd
QISCP81-1

Watch Wireless Charger

Oct 22, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote Radio Unit - FCC ID QISRRU3278 - Huawei Technologies Co.,Ltd
QISRRU3278

Remote Radio Unit

Sep 02, 2020

Equipment Class

CBD - Citizens Band Category A and B Devices
Indoor Router - FCC ID QISR2561 - Huawei Technologies Co.,Ltd
QISR2561

Indoor Router

Jul 11, 2020

Equipment Class

DTS - Digital Transmission System
Solar Smart Monitor & Data Logger - FCC ID QISSMARTLOGGER310 - Huawei Technologies Co.,Ltd
QISSMARTLOGGER310

Solar Smart Monitor & Data Logger

Mar 23, 2020

Equipment Class

DTS - Digital Transmission System