FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Huawei Technologies Co.,Ltd/
  3. QISY330-U15

QISY330-U15WCDMA Digital Mobile Phone

Huawei Technologies Co.,Ltd
WCDMA Digital Mobile Phone - FCC ID QISY330-U15 - Huawei Technologies Co.,Ltd
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Apr 10, 2014
Application Purpose
Original Equipment
Date of Application
Apr 10, 2014
Equipment Note
WCDMA Digital Mobile Phone
Frequency Range
1852.40000000 - 1907.60000000
Company
Huawei Technologies Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick Start Guide Y330 HUAWEI Dual card dual standby single pass Your phone supports only dual card dual standby single pass, which means you cannot use both SIM cards for calls or data services simultaneously. • When you are on a call using SIM card 1, SIM card 2 cannot be used to make or answer calls. If someone calls SIM card 2, the caller will hear a voice message similar to "The subscriber you dialed is out of the service area" or "The subscriber you dialed cannot be connected for the moment, please try again later." • When you are using SIM card 1's data service, SIM card 2's data service will be disabled. Your phone's single pass feature helps reduce power consumption and increase your phone's standby time. It may be a good idea to contact your service provider and subscribe to missed call reminder and related assistance services to avoid the conflicts mentioned above. Your phone at a glance Thank you for choosing the HUAWEI Ascend Y330 smartphone. Before you start, let's take a look at your new phone. Earpiece Headset jack Home Micro USB port Return Volume button Menu Power button Installation Caution When you install a SIM card, make sure you do not mix up the slots of WCDMA and GSM cards. Otherwise your phone may fail to detect the SIM card. Follow the instructions in the following figures to complete the installation. Then press and hold the power button to power on your phone. 1 5VKTZNKHGZZKX_IU\KX 2 /TYKXZZNK9/3IGXJY /TYKXZZNKSOIXU9*IGXJUVZOUTGR 3 )NGXMKZNKVNUTK /TYZGRRZNKHGZZKX_ /TYZGRRZNKHGZZKX_IU\KX 4 5 6 a b Dual-card management Go to and touch SIM card management to enable or disable your SIM cards. You can enable the two SIM cards simultaneously. Touch Data connection to set the default SIM card for your data service. Locking and unlocking the screen Your phone automatically locks its screen after being idle for a specified period of time. Alternatively, you can press the power button to manually lock the screen. You can go to and touch Display > Sleep to set the screen timeout period. If the screen is off, press the power button to turn it on. Slide your finger in any direction to unlock the screen.   Managing contacts Touch to open Contacts. Go to the Favorites tab to mark a contact as your favorite or manage contact groups. On the Contacts screen, touch > Import/Export to import contacts from other devices or export contacts on your phone. Create a contact Placing a call Touch and enter a phone number on the dialer. If you have existing contacts on your phone, your phone automatically displays matching results as you type. Touch a number to place a call. You can also touch a number from Contacts, Messaging, Email, or Browser to place a call. 400 12 Messaging Touch to open Messaging. Attaching a file to a text message converts the message into a multimedia message. You can save photos, audio clips, or videos from received multimedia messages. When you are typing, open the notification panel and touch to switch the input method. ********** Hello! Attach a file Camera Touch to open Camera. Touch to take a photo. To shoot a video, frame the scene you want to record and touch to start shooting. Switch the capture mode View your photos Editing a photo Touch to open Gallery. When browsing a photo, touch to edit it. You can then crop it, adjust its color, apply filters or frames to it, and more. Edit the photo Listening to music Touch to open Music. Play your songs by name, artist, or album, and mark your favorite songs. Phone Manager Phone Manager supports system diagnosis and optimization at the touch of a button. You can configure your phone's power saving mode, manage application permissions, clean up your storage, and turn on do not disturb mode. Touch to open Phone Manager. Touch to scan Flick left for more functions More information Encounter any issues while using your phone? For the full user guide, go to  http://consumer.huawei.com/en/ and search for  HUAWEI Ascend Y330. Want to learn more about Huawei Emotion UI? Visit http://en.ui.vmall.com/ for the latest information. Legal Notice Copyright © Huawei Technologies Co., Ltd. 2014. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. and its affiliates ("Huawei"). The product described in this manual may include copyrighted software of Huawei and possible licensors. Customers shall not in any manner reproduce, distribute, modify, decompile, disassemble, decrypt, extract, reverse engineer, lease, assign, or sublicense the said software, unless such restrictions are prohibited by applicable laws or such actions are approved by respective copyright holders. Trademarks and Permissions , , and are trademarks or registered trademarks of Huawei Technologies Co., Ltd. Android™ is a trademark of Google Inc. The Bluetooth ® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Huawei Technologies Co., Ltd. is under license. Other trademarks, product, service and company names mentioned may be the property of their respective owners. Notice Some features of the product and its accessories described herein rely on the software installed, capacities and settings of local network, and therefore may not be activated or may be limited by local network operators or network service providers. Thus, the descriptions herein may not exactly match the product or its accessories which you purchase. Huawei reserves the right to change or modify any information or specifications contained in this manual without prior notice and without any liability. Third-Party Software Statement Huawei does not own the intellectual property of the third- party software and applications that are delivered with this product. Therefore, Huawei will not provide any warranty of any kind for third party software and applications. Neither will Huawei provide support to…

Text truncated - open the document above for the full version.

Cover Letter(s)

Huawei Technologies Co.,Ltd. Federal Communications Commission 2014-04-01 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: QISY330-U15 To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Operational Description Bom List Tune-Up Procedure Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. ***************************************************************************** In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the Commission withholds the following documents from public viewing until 2014-08-30: External Photos Internal Photos Test Setup Photos User Manual ****************************************************************************** It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards Zhang Xinghai EMC Laboratory Manager Huawei Technologies Co., Ltd. Address: Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C E-mail: [email protected] Tel: 0086-0755-28970299 Fax: 0086-0755-89650226

Cover Letter(s)

Huawei Technologies Co.,Ltd. 10-04-2014 Federal Communication Commission Equipment Authorization Devision, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 Declaration on Electrically Identical Models TO WHOM IT MAY CONCERN We, <Huawei Technologies Co.,Ltd>, declare on our sole responsibility that the new model < HUAWEI Y330-U15, Y330-U15> with FCC ID: <QISY330-U15 > is identical in hardware and software to the certified model < HUAWEI Y330-U05, Y330-U05> under FCC ID: <QISY330-U05> The only differences between the new model and the original model are: - Model < HUAWEI Y330-U05, Y330-U05> is equipped with one SIM card. Model < HUAWEI Y330-U15, Y330-U15> is equipped with double SIM cards only We attest that above changing are not relevant for any RF behaviour subject to regulatory items. Additional Spurious Emissions measurements on representative configurations have been performed to justify. Therefore all test reports remains applicable. If you have any questions, please feel free to contact us at the address shown below Sincerely, Zhang Xinghai EMC Laboratory Manager Huawei Technologies Co.,Ltd Address: Administration Building, Headquarters of Huawei Technologies Co., Ltd., Tel: 0086-0755-28970299 Fax: 0086-0755-89650226

External Photos

HUAWEI Y330-U05, Y330-U05 WCDMA Digital Mobile Phone Secret 2014-2-26 Page1, Total3 External Photos of HUAWEI Y330-U05, Y330-U05 HUAWEI Y330-U05, Y330-U05 WCDMA Digital Mobile Phone Secret 2014-2-26 Page2, Total3 HUAWEI Y330-U05, Y330-U05 WCDMA Digital Mobile Phone Secret 2014-2-26 Page3, Total3

ID Label/Location Info

Huawei Technologies Co.,Ltd. Statement We, Huawei Technologies Co.,Ltd.states that our device, FCC ID: QISY330-U15, has a battery, But the battery will not be placed in the battery compartment when delivery, it is visible to the users as they purchase the products and install the battery. For and Behalf of: Huawei Technologies Co., Ltd. Zhang Xinghai EMC Laboratory Manager Address: Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C E-mail: [email protected] Tel: 0086-0755-28970299 Fax: 0086-0755-89650226

ID Label/Location Info

HUAWEI Y330-U15,Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-4-1 Page1, Total2 Label & Label Location: HUAWEI Y330-U15,Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-4-1 Page2, Total2

Internal Photos

HUAWEI Y330-U15, Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-04-01 Page1, Total9 Internal Photos of HUAWEI Y330-U15, Y330-U15 HUAWEI Y330-U15, Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-04-01 Page2, Total9 HUAWEI Y330-U15, Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-04-01 Page3, Total9 HUAWEI Y330-U15, Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-04-01 Page4, Total9 HUAWEI Y330-U15, Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-04-01 Page5, Total9 HUAWEI Y330-U15, Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-04-01 Page6, Total9 HUAWEI Y330-U15, Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-04-01 Page7, Total9 HUAWEI Y330-U15, Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-04-01 Page8, Total9 HUAWEI Y330-U15, Y330-U15 WCDMA Digital Mobile Phone SECRET 2014-04-01 Page9, Total9

RF Exposure Info

Report No.: RHA1402-0029SAR01R3 Page 1 of 255 TESTING No. L2264 SAR TEST REPORT Product Name WCDMA Digital Mobile Phone Model Name HUAWEI Y330-U15,Y330-U15 FCC ID QISY330-U15 Client Huawei Technologies Co., Ltd. Manufacturer Huawei Technologies Co., Ltd. Date of issue April 2, 2014 TA Technology (Shanghai) Co., Ltd. TA Technology (Shanghai) Co., Ltd. Test Report Report No.: RHA1402-0029SAR01R3 Page 2 of 255 GENERAL SUMMARY Reference Standard(s) FCC 47CFR §2.1093 Radiofrequency Radiation Exposure Evaluation: Portable Devices ANSI C95.1, 1992: Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz.(IEEE Std C95.1-1991) IEEE Std 1528™-2003: IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques. RSS-102 Issue 4 March 2010: Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) KDB 865664 D01 SAR measurement 100 MHz to 6 GHz v01r03: SAR Measurement Requirements for 100 MHz to 6 GHz KDB 447498 D01 Mobile Portable RF Exposure v05r02: Mobile and Portable Device RF Exposure Procedures and Equipment Authorization Policies KDB 648474 D04 Handset SAR v01r02: SAR Evaluation Considerations for Wireless Handsets. KDB 941225 D01 SAR test for 3G devices v02: SAR Measurement Procedures CDMA 20001x RTT, 1x Ev-Do, WCDMA, HSDPA/HSPA KDB 941225 D02 HSPA and 1x Advanced v02r02 SAR Guidance for HSPA, HSPA+, DC-HSDPA and 1x-Advanced KDB 941225 D03 Test Reduction GSM_GPRS_EDGE v01:Recommended SAR Test Reduction Procedures for GSM/GPRS/EDGE KDB 941225 D06 Hotspot Mode SAR v01r01: SAR Evaluation Procedures for Portable Devices with Wireless Router Capabilities KDB 248227 D01 SAR meas for 802 11 a b g v01r02: SAR Measurement Procedures for 802.11a/b/g Transmitters. Conclusion This portable wireless equipment has been measured in all cases requested by the relevant standards. Test results in Chapter 7 of this test report are below limits specified in the relevant standards for the tested bands only. General Judgment: Pass Comment The test result only responds to the measured sample. Approved by Weizhong Yang Director Revised by Minbao Ling SAR Manager Performed by Yi Zhang SAR Engineer TA Technology (Shanghai) Co., Ltd. Test Report Report No.: RHA1402-0029SAR01R3 Page 3 of 255 TABLE OF CONTENT 1. General Information ..................................................................................................................... 5 1.1. Notes of the Test Report ....................................................................................................... 5 1.2. Testing Laboratory ................................................................................................................ 5 1.3. Applicant Information ............................................................................................................ 6 1.4. Manufacturer Information ...................................................................................................... 6 1.5. Information of EUT ................................................................................................................ 7 1.6. The Maximum Reported SAR 1g ............................................................................................ 9 1.7. Maximum Conducted Power of each tested Mode .............................................................. 10 1.8. Test Date ............................................................................................................................ 10 2. SAR Measurements System Configuration ................................................................................ 11 2.1. SAR Measurement Set-up .................................................................................................. 11 2.2. DASY5 E-field Probe System ............................................................................................. 12 2.2.1. EX3DV4 Probe Specification ....................................................................................... 12 2.2.2. E-field Probe Calibration .............................................................................................. 13 2.3. Other Test Equipment ......................................................................................................... 13 2.3.1. Device Holder for Transmitters .................................................................................... 13 2.3.2. Phantom ...................................................................................................................... 14 2.4. Scanning Procedure ........................................................................................................... 14 2.5. Data Storage and Evaluation .............................................................................................. 16 2.5.1. Data Storage ................................................................................................................ 16 2.5.2. Data Evaluation by SEMCAD ...................................................................................... 16 3. Laboratory Environment ............................................................................................................. 18 4. Tissue-equivalent Liquid ............................................................................................................ 19 4.1. Tissue-equivalent Liquid Ingredients ................................................................................... 19 4.2. T issue-equivalent Liquid Properties .................................................................................... 21 5. System Check ............................................................................................................................ 22 5.1. Description of System Check ..........................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

TA Technology (Shanghai) Co., Ltd. Test Report Report No.: RHA1402-0029SAR01R3 Page 167 of 255 802.11b Right Cheek Low (Battery 1) Date/Time: 2014-03-22 19:04:48 Communication System: 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2412 MHz; σ = 1.759 S/m; ε r = 39.353; ρ = 1000 kg/m 3 Ambient Temperature:22.3 °C Liquid Temperature: 21.5°C Phantom section: Right Section DASY5 Configuration: Sensor-Surface: 4mm (Mechanical Surface Detection) Probe: EX3DV4 - SN3677; ConvF(7.64, 7.64, 7.64); Calibrated: 2013-11-28; Electronics: DAE4 Sn1317; Calibrated: 2014-01-16 Phantom: SAM 2; Type: QD000P40CD; Serial: TP1667 Measurement SW: DASY52, Version 52.8 (5); SEMCAD X Version 14.6.8 (7028) Right Cheek Low/Area Scan (61x101x1): Interpolated grid: dx=12mm, dy=12mm Maximum value of SAR (interpolated) = 0.198 W/kg Right Cheek Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 7.890 V/m; Power Drift = 0.067 dB Peak SAR (extrapolated) = 0.342 W/kg SAR(1 g) = 0.171 W/kg; SAR(10 g) = 0.096 W/kg Maximum value of SAR (measured) = 0.182 W/kg TA Technology (Shanghai) Co., Ltd. Test Report Report No.: RHA1402-0029SAR01R3 Page 168 of 255 Figure 105 Right Hand Touch Cheek 802.11b Channel 1 TA Technology (Shanghai) Co., Ltd. Test Report Report No.: RHA1402-0029SAR01R3 Page 169 of 255 802.11b Right Tilt Low (Battery 1) Date/Time: 2014-03-22 19:21:07 Communication System: 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2412 MHz; σ = 1.759 S/m; ε r = 39.353; ρ = 1000 kg/m 3 Ambient Temperature:22.3 °C Liquid Temperature: 21.5°C Phantom section: Right Section DASY5 Configuration: Sensor-Surface: 4mm (Mechanical Surface Detection) Probe: EX3DV4 - SN3677; ConvF(7.64, 7.64, 7.64); Calibrated: 2013-11-28; Electronics: DAE4 Sn1317; Calibrated: 2014-01-16 Phantom: SAM 2; Type: QD000P40CD; Serial: TP1667 Measurement SW: DASY52, Version 52.8 (5); SEMCAD X Version 14.6.8 (7028) Right Tilt Low/Area Scan (61x101x1): Interpolated grid: dx=12mm, dy=12mm Maximum value of SAR (interpolated) = 0.174 W/kg Right Tilt Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 8.965 V/m; Power Drift = 0.020 dB Peak SAR (extrapolated) = 0.318 W/kg SAR(1 g) = 0.153 W/kg; SAR(10 g) = 0.080 W/kg Maximum value of SAR (measured) = 0.164 W/kg Figure 106 Right Hand Tilt 15° 802.11b Channel 1 TA Technology (Shanghai) Co., Ltd. Test Report Report No.: RHA1402-0029SAR01R3 Page 170 of 255 802.11b Right Cheek Low (Battery 2) Date/Time: 2014-03-22 20:51:41 Communication System: 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2412 MHz; σ = 1.759 S/m; ε r = 39.353; ρ = 1000 kg/m 3 Ambient Temperature:22.3 °C Liquid Temperature: 21.5°C Phantom section: Right Section DASY5 Configuration: Sensor-Surface: 4mm (Mechanical Surface Detection) Probe: EX3DV4 - SN3677; ConvF(7.64, 7.64, 7.64); Calibrated: 2013-11-28; Electronics: DAE4 Sn1317; Calibrated: 2014-01-16 Phantom: SAM 2; Type: QD000P40CD; Serial: TP1667 Measurement SW: DASY52, Version 52.8 (5); SEMCAD X Version 14.6.8 (7028) Right Cheek Low/Area Scan (61x101x1): Interpolated grid: dx=12mm, dy=12mm Maximum value of SAR (interpolated) = 0.192 W/kg Right Cheek Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 7.867 V/m; Power Drift = 0.026 dB Peak SAR (extrapolated) = 0.331 W/kg SAR(1 g) = 0.163 W/kg; SAR(10 g) = 0.090 W/kg Maximum value of SAR (measured) = 0.172 W/kg Figure 107 Right Hand Touch Cheek 802.11b Channel 1 TA Technology (Shanghai) Co., Ltd. Test Report Report No.: RHA1402-0029SAR01R3 Page 171 of 255 802.11b Right Cheek Low (Battery 3) Date/Time: 2014-03-22 20:33:36 Communication System: 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2412 MHz; σ = 1.759 S/m; ε r = 39.353; ρ = 1000 kg/m 3 Ambient Temperature:22.3 °C Liquid Temperature: 21.5°C Phantom section: Right Section DASY5 Configuration: Sensor-Surface: 4mm (Mechanical Surface Detection) Probe: EX3DV4 - SN3677; ConvF(7.64, 7.64, 7.64); Calibrated: 2013-11-28; Electronics: DAE4 Sn1317; Calibrated: 2014-01-16 Phantom: SAM 2; Type: QD000P40CD; Serial: TP1667 Measurement SW: DASY52, Version 52.8 (5); SEMCAD X Version 14.6.8 (7028) Right Cheek Low/Area Scan (61x101x1): Interpolated grid: dx=12mm, dy=12mm Maximum value of SAR (interpolated) = 0.182 W/kg Right Cheek Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 8.061 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.321 W/kg SAR(1 g) = 0.161 W/kg; SAR(10 g) = 0.089 W/kg Maximum value of SAR (measured) = 0.167 W/kg Figure 108 Right Hand Touch Cheek 802.11b Channel 1 TA Technology (Shanghai) Co., Ltd. Test Report Report No.: RHA1402-0029SAR01R3 Page 172 of 255 802.11b Right Cheek Low (Battery 4) Date/Time: 2014-03-22 21:29:10 Communication System: 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2412 MHz; σ = 1.759 S/m; ε r = 39.353; ρ = 1000 kg/m 3 Ambient Temperature:22.3 °C Liquid Temperature: 21.5°C Phantom section: Right Section DASY5 Configuration: Sensor-Surface: 4mm (Mechanical Surface Detection) Probe: EX3DV4 - SN3677; ConvF(7.64, 7.64, 7.64); Calibrated: 2013-11-28; Electronics: DAE4 Sn1317; Calibrated: 2014-01-16 Phantom: SAM 2; Type: QD000P40CD; Serial: TP1667 Measurement SW: DASY52, Version 52.8 (5); SEMCAD X Version 14.6.8 (7028) Right Cheek Low/Area Scan (61x101x1): Interpolated grid: dx=12mm, dy=12mm Maximum value of SAR (interpolated) = 0.201 W/kg Right Cheek Low/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 7.704 V/m; Power Drift = 0.043 dB Peak SAR (extrapolated) = 0.353 W/kg SAR(1 g) = 0.170 W/kg; SAR(10 g) = 0.094 W/kg Maximum value of SAR (measured) = 0.183 W/kg Figure 109 Right Hand Touch Cheek 802.11b Channel 1 TA Technology (Shanghai) Co., Ltd. Test Report Report No.: RHA1402-0029SAR01R3 Page 173 of 255 802.11b Right Cheek Low (Battery 5) Date/Time: 2014-03-22…

Text truncated - open the document above for the full version.

Test Report

FCC RF Test Report Product Name: WCDMA Digital Mobile Phone Model Number: HUAWEI Y330-U05, Y330-U05 Report No: SYBH(Z-RF)007012014-2001 FCC ID:QISY330-U05 Reliability Laboratory of Huawei Technologies Co., Ltd. Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C Tel: +86 755 28780808 Fax: +86 755 89652518 RF Test Report of HUAWEI Y330-U05, Y330-U05 Report No: SYBH(Z-RF)007012014-2001 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Page 2 of 21 Notice 1. The laboratory has Passed the accreditation by China National Accreditation Service for Conformity Assessment (CNAS). The accreditation number is L0310. 2. The laboratory has Passed the accreditation by The American Association for Laboratory Accreditation (A2LA). The accreditation number is 2174.01. 3. The laboratory has been listed by the US Federal Communications Commission to perform electromagnetic emission measurements. The site recognition number is 97456. 4. The laboratory has been listed by Industry Canada to perform electromagnetic emission measurements. The recognition numbers of test site are 6369A-2. 5. The test report is invalid if not marked with the signatures of the persons responsible for preparing and approving the test report. 6. The test report is invalid if there is any evidence of erasure and/or falsification. 7. The test report is only valid for the test samples. 8. Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes without prior written approval from the laboratory. RF Test Report of HUAWEI Y330-U05, Y330-U05 Report No: SYBH(Z-RF)007012014-2001 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Page 3 of 21 Applicant: Huawei Technologies Co., Ltd. Address: Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C Date of Receipt Sample: 2014-01-02 Start Date of Test: 2014-01-05 End Date of Test: 2014-01-18 Test Result: Pass Approved by Senior Engineer: 2014-02-22 Dai Linjun Date Name Signature Prepared by: 2014-02-22 Ling Kaiyun Date Name Signature RF Test Report of HUAWEI Y330-U05, Y330-U05 Report No: SYBH(Z-RF)007012014-2001 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Page 4 of 21 Modification Record No. Last Report No. Modification Description 1 First report. RF Test Report of HUAWEI Y330-U05, Y330-U05 Report No: SYBH(Z-RF)007012014-2001 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Page 5 of 21 CONTENT 1 General Information ................................................................................................................................................ 6 1.1 Applied Standard........................................................................................................................................ 6 1.2 Test Location ............................................................................................................................................. 6 1.3 Test Environment Condition ....................................................................................................................... 6 2 Test Summary ........................................................................................................................................................ 7 2.1 Cellular Band (824-849 MHz paired with 869-894 MHz) ............................................................................ 7 2.2 PCS Band (1850-1915 MHz paired with 1930-1995 MHz) ......................................................................... 8 3 Description of the Equipment under Test (EUT) ..................................................................................................... 9 3.1 General Description ................................................................................................................................... 9 3.2 EUT Identity ............................................................................................................................................... 9 3.3 Technical Specification ............................................................................................................................ 10 4 General Test Conditions / Configurations ............................................................................................................. 11 4.1 Test Modes .............................................................................................................................................. 11 4.2 Test Environment ..................................................................................................................................... 11 4.3 Test Frequency ........................................................................................................................................ 12 4.4 DESCRIPTION OF TESTS ...................................................................................................................... 13 4.5 Test Setups .............................................................................................................................................. 16 4.6 Test Conditions ........................................................................................................................................ 18 5 Main Test Instruments .......................................................................................................................................... 20 6 Measurement Uncertainty..................................................................................................................................... 21 RF Test Report of HUAWEI Y330-U05, Y330-U05 Report No: SYBH(Z-RF)007012014-2001 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Page 6 of 21 1 General Information 1.1 Applied Standard Applied Rul…

Text truncated - open the document above for the full version.

Test Report

RF Test Report of HUAWEI Y330-U05 Report No: SYBH(Z-RF)007012014-2001 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Page 1 of 85 Appendix for test report RF Test Report of HUAWEI Y330-U05 Report No: SYBH(Z-RF)007012014-2001 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Page 2 of 85 APPENDIX FOR TEST REPORT 1APPENDIX_A: EFFECTIVE (ISOTROPIC) RADIATED POWER OUTPUT DATA ............................................................ 3 Part I - Test Results ............................................................................................................................................. 3 2APPENDIX_B: PEAK-TO-AVERAGE RATIO ....................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Zhang Xinghai
[email protected]+86-755-2897-0299Fax: +86-755-8965-0226

Test Firm

Huawei Technologies Co., LTDZhou Fengyum
[email protected]86-755-28782917Fax: 86-755-89650226

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
424E1.85 GHz - 1.91 GHz187.00 mW4M18F9W0.004 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is ERP for Part 22 and EIRP for Part 24 and Part 27. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. For body worn operation, this phone has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the handset a minimum of 10 mm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR for head, body-worn, wireless router and simultaneous transmission use conditions are 0.97 W/kg, 1.48 W/kg, 1.48 W/Kg and 1.48 W/Kg, respectively.

Other Applications from Huawei Technologies Co.,Ltd

Solar Inverter - FCC ID QISSUN2000 - Huawei Technologies Co.,Ltd
QISSUN2000

Solar Inverter

Jun 27, 2021

Equipment Class

DTS - Digital Transmission System
Watch Wireless Charger - FCC ID QISCP81-1 - Huawei Technologies Co.,Ltd
QISCP81-1

Watch Wireless Charger

Oct 22, 2020

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Remote Radio Unit - FCC ID QISRRU3278 - Huawei Technologies Co.,Ltd
QISRRU3278

Remote Radio Unit

Sep 02, 2020

Equipment Class

CBD - Citizens Band Category A and B Devices
Indoor Router - FCC ID QISR2561 - Huawei Technologies Co.,Ltd
QISR2561

Indoor Router

Jul 11, 2020

Equipment Class

DTS - Digital Transmission System
Solar Smart Monitor & Data Logger - FCC ID QISSMARTLOGGER310 - Huawei Technologies Co.,Ltd
QISSMARTLOGGER310

Solar Smart Monitor & Data Logger

Mar 23, 2020

Equipment Class

DTS - Digital Transmission System