1 Helen Zhao Subject:FW: answer: Secure Wireless, Inc., FCC ID: QNPEVP319, Assessment NO.: AN04T4394, Notice#1 User Manual(revised).pdf -----Original Message----- From: Claire Hoque Sent: Thursday, December 16, 2004 11:14 AM To: Helen Zhao Cc: Kathy Yao Subject: answer: Secure Wireless, Inc., FCC ID: QNPEVP319, Assessment NO.: AN04T4394, Notice#1 Hi Helen, Here is the answer. Question #1: The user manual does not contain warning statement(Information to the User) as specified in FCC 15.21. Please revise the user manual. <answer>User's manual is revised. The associated receiver for this transmitter is ITI and Caddx Receiver(FCC ID:B4Z-787E-SIMON) Thanks, Claire
PROPOSED FCC ID LABEL AND LOCATION Secure Wireless, Inc. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: QNP-EVP319 FCC ID LABEL
Innovator in Wireless Security System Ltd. FREELINK LTD. 57, Hamelacha St. Holon 58855 Israel Tel. 03-5564352 Fax. 03-5589427 FW-P500 WIRELESS PIR DETECTOR V1.0, 1-11-2004 ------------------------------------------------------------------------------------------------------------------------ Explanation of the block diagram The FW-P500 wireless detector is Battery powered passive infrared motion detector (ASIC based) with an onboard transmitter. It has unique Automatic Power Saver (APS) circuit designed to conserve battery life. Both transmitter and detector circuits are powered by a commercial 2/3 AA Lithium battery with up to 3 years of battery life. When the passive infrared sensor detects motion in its filed of view, the ASIC triggers the on-board transmitter that Transmits its specific ID followed by an alarm signal and battery condition. The APS (Alarm Power Saver) mechanism is that alarm signal is transmitted only after 2 minutes of mask time after the last event of the alarm. If detector cover is removed - a microswitch is opened and the ASIC triggers the on-board transmitter for tamper signal. A periodic Transmission for supervision purposes takes place automatically once in ~ 60 min. In the event of low battery, when the power supply drops below the threshold level, low battery signal will be transmitted at supervision transmission.
55 44 33 22 11 D D C C B B A A WALK TEST - < 1 Sec. TRANSMIT TEST - > 1 Sec. PCB THICKNESS 1.6MM !! diode & rc areused as SoftStart & protectwhen VPPapplied 1.9<vcc<5.5 1 PULSE AUTO 25Kg PET 15Kg N.C. FrontTamper C13 =22uF/6.3V havebeen change to 10uF/16Vas Melman Request(PETability 50lbs). A Wednesday, November 24, 2004 11 A3 FW-P500P-3S FW-P500P-3S.DSN E.R. D.S. 3202583 D.F. 45E58302 Size Scale PCB NO DWG NO Rev Sheet of FNC. NAME DATE SIGN. DES.CHK. APR. 57, Hamlacha St. Holon 58855 Tel. 03-5569937 DESING FILENAME: FreeLink Confidential Information. All Rights Reserved. PIROUTLOWBATTRANS TESTBAT PROG_CLK RESET PROG_CLK RESET PROG_DATA PIROUTENTX LOWBAT PROG_DATA ASKDTA RESET TESTBATTAMPERTRANS ENTX ASKDTA TAMPER VCC VCC VCC VCC VCC VCC VCC VCC VCC VCC VCC R92M R268K C61nFR110K S1 Tact Switch C2410nF R62M D1RLS4148 C111nF R16 150K C1210nF + C4 100uF/6.3V JP2 N.C. 1 2 R41M D5BAT64-06 C25330pF C1010nF BT1BAT 3V BC2/3AE C31nF C11nF C21N.C. JP1 2 HEADER SHORT LEGS 12 C28N.C. ANT1 1 T°C RT1 Thermistor 10K DM-03S-1P S3 1 32 D2 MMSZ4678BT1 S2Reed Switch C20 27pF D3RLS4007 R240R R250R U2 PIC16F630 1234567 891011121314 VddRA5*RA4*RA3/MCLR/VPPRC5RC4RC3 RC2 RC1RC0 RA2*RA1*RA0* Vss + C1310uF/16V C9N.C. Y2 9.984375MHz HC49S SMD + C3122uF/6.3V R78.2K C29100nF R14 10K L2 47nH SW1 SW SLIDE C234pF P I R DG S Q1IR-14 1 2 3 + C17100uF/6.3V C18470pF C30100nF R17N.C. ON Q1 Rubber Ring 12mm C27 33pF L139nH U1AS1011A 1357 1211 2468 131415161718 9 10 CH1GNDPULSVCCA TRANS LED AINAOUTRSCWALK LOWBAT PIROUT SUPRV MODE BATIN LP1 TAMPER VCC C2222pFC2610nF SW2 SW SLIDE C71nF R111K LD1BLUE LED J5 N.C. 12345 C1610nF R510K U4 TH72002 1234 5678 ASKDTAN.C.ROIENTX PSEL VCC OUT VEE R15330K C210nF + C5100uF/6.3V S4 2 31 C15100nF
FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR SECURE WIRELESS PET IMMUNE PIR MODEL: EV-P319 FCC ID: QNP-EVP319 REPORT NUMBER: 04U3121-1 ISSUE DATE: NOVEMBER 30, 2004 Prepared for SECURE WIRELESS, INC. 1185 PARK CENTER DRIVE VISTA, CA. 92083 U.S.A Prepared by COMPLIANCE ENGINEERING SERVICES, INC. d.b.a. COMPLIANCE CERTIFICATION SERVICES 561F MONTEREY ROAD MORGAN HILL, CA 95037 USA TEL: (408) 463-0885 FAX: (408) 463-0888 Revision History Rev. Revisions Revised By REPORT NO: 04U3121 DATE: NOVEMBER 30, 2004 EUT: SECURE WIRELESS PET IMMUNE PIR FCC ID: QNP-EVP319 PAGE 3 of 23 COMPLIANCE CERTIFICATION SERVICES CCS DOCUMENT NO:CCSUP4020B 561F MONTEREY RD., MORGAN HILL, CA 95037, USA TEL:(408)463-0885 FAX:(408)463-0888 This report shall not be reproduced except in full, without the written approval of CCS. This document may be altered or revised by Compliance Certification Services personnel only, and shall be noted in the revision section of the document. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS .......................................................................................4 2. TEST METHODOLOGY ............................................................................................................5 3. FACILITIES AND ACCREDITATION .....................................................................................5 4. CALIBRATION AND UNCERTAINTY ...................................................................................5 4.1 MEASURING INSTRUMENT CALIBRATION .........................................................5 4.2 MEASUREMENT UNCERTAINTY............................................................................5 5. PRODUCT DESCRIPTION ........................................................................................................6 6. MEASUREMENT EQUIPMENT USED....................................................................................6 7. POWERLINE RFI LIMIT ...........................................................................................................6 8. RADIATED EMISSION LIMITS ...............................................................................................6 9. SYSTEM TEST CONFIGURATION .........................................................................................7 10. TEST PROCEDURE .................................................................................................................8 11. EUT MODIFICATION ...........................................................................................................10 12. TEST RESULT ........................................................................................................................11 12.1 RADIATED EMISSIONS TEST DATA ..................................................................11 12.1 MAXIMUM MODULATION PERCENTAGE (M%) .............................................13 12.2 LESS THAN 5 SECOND PLOT ...............................................................................18 12.3 EMISSION BANDWIDTH .......................................................................................19 13. EUT PHOTOGRAPHS............................................................................................................20 REPORT NO: 04U3121 DATE: NOVEMBER 30, 2004 EUT: SECURE WIRELESS PET IMMUNE PIR FCC ID: QNP-EVP319 PAGE 4 of 23 COMPLIANCE CERTIFICATION SERVICES CCS DOCUMENT NO:CCSUP4020B 561F MONTEREY RD., MORGAN HILL, CA 95037, USA TEL:(408)463-0885 FAX:(408)463-0888 This report shall not be reproduced except in full, without the written approval of CCS. This document may be altered or revised by Compliance Certification Services personnel only, and shall be noted in the revision section of the document. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: SECURE WIRELES SYSTEMS INC. 1185 PARK CENTER DRIVE VISTA, CA. 92083 U.S.A. EUT DESCRIPTION: SECURE WIRELESS PET IMMUNE PIR MODEL NO: EV-P319 FCC ID: QNP-EVP319 DATE OF TESTED: NOVEMBER 23-30, 2004 REPORT NO: 04U3121-1 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C NO NON-COMPLIANCE NOTED Compliance Certification Services, Inc. tested the above equipment in accordance with the requirements set forth in the above standards. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by Compliance Certification Services and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by Compliance Certification Services will constitute fraud and shall nullify the document. No part of this report may be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any government agency. Tested By: Approved & Released By: CHIN PANG THU CHAN EMC TECHNICIAN EMC SUPERVISOR COMPLIANCE CERTIFICATION SERVICES COMPLIANCE CERTIFICATION SERVICES REPORT NO: 04U3121 DATE: NOVEMBER 30, 2004 EUT: SECURE WIRELESS PET IMMUNE PIR FCC ID: QNP-EVP319 PAGE 5 of 23 COMPLIANCE CERTIFICATION SERVICES CCS DOCUMENT NO:CCSUP4020B 561F MONTEREY RD., MORGAN HILL, CA 95037, USA TEL:(408)463-0885 FAX:(408)463-0888 This report shall not be reproduced except in full, without the written approval of CCS. This document may be altered or revised by Compliance Certification Services personnel only, and shall be noted in the revision section of the document. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with ANSI C63.4-2003, FCC CFR 47 Part 2 and FCC CFR 47 Part 15. 3. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 561F Monterey Road, Morgan Hill, California, USA. The sites are constructed in conformance with the requirements of ANSI C63.4, ANSI C63.7 …
Text truncated - open the document above for the full version.
REPORT NO: 04U3121 DATE: NOVEMBER 30, 2004 EUT: SECURE WIRELESS PET IMMUNE PIR FCC ID: QNP-EVP319 PAGE 7 of 23 COMPLIANCE CERTIFICATION SERVICES CCS DOCUMENT NO:CCSUP4020B 561F MONTEREY RD., MORGAN HILL, CA 95037, USA TEL:(408)463-0885 FAX:(408)463-0888 This report shall not be reproduced except in full, without the written approval of CCS. This document may be altered or revised by Compliance Certification Services personnel only, and shall be noted in the revision section of the document. 9. SYSTEM TEST CONFIGURATION Use a block of foam and combined it with EUT wrapping rubber band around it. This way it can test X, Y, and Z axis. To activate continuous transmission, reset jumper and press 8 times on S3 button. Radiated Open Site Test Set-up X-Axis Y-Axis Z-Axis
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 319 MHz - 319 MHz | - |

DEVICE CONTROLLER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
DEVICE CONTROLLER
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
DEVICE CONTROLLER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
DEVICE CONTROLLER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Repeater
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver