FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Philio Technology Corporation/
  3. RHHPAN08

RHHPAN08In Wall Switch

Philio Technology Corporation
In Wall Switch - FCC ID RHHPAN08 - Philio Technology Corporation
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Jul 24, 2013
Application Purpose
Original Equipment
Date of Application
Jul 22, 2013
Equipment Note
In Wall Switch
Frequency Range
908.42000000 - 908.42000000
Company
Philio Technology Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PAN08-1/-2/-3 Roller shutter controller P Fig 1. Assembling The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using radio waves, controllers and a push button directly connected to this Roller Controller. This in-wall Roller Shutter Controller is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter. This in-wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method, so it can be remote controlled not only fully up or down , but also can be adjusted to ex. 30% or 50%. And when manual controlled by push button, the controller also can memorize the position and send the new shutter position to its controller (ex. IP-Gateway). Adding to Z-Wave TM Network In the front casing, there is an include button with LED indicator below which is used to carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices. Auto Inclusion The function of auto inclusion will be executed as long as the PAN08 does not have Node ID and just connect the PAN08 to main power. Note: Auto inclusion timeout is 4 minute during which the node information of 1 explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the Include button on the PAN08. The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devices FunctionDescriptionLED Indication No node IDThe Z-Wave Controller does not allocate a node ID to the PAN08. 2-second on, 2-second off Inclusion1.Have Z-Wave Controller entered inclusion mode. One press one flash 2. Pressing Include button three times within 1.5 seconds will enter inclusion mode. Exclusion1.Have Z-Wave Controller entered exclusion mode. One press one flash 2.Pressing Include button three times within 1.5 seconds will enter exclusion mode. Node ID has been excluded.2-second on, 2-second off Reset1.Pressing Include button three times within 1.5 seconds will enter inclusion mode. One press one flash 2.Within 1 second, press Include button again for 5 seconds until LED is off. 3.IDs are excluded.2-second on, 2-second off Association1.Have Z-Wave Controller entered association mode. Or Pressing Include button three times within 1.5 seconds will enter association mode One press one flash 2. There are 1 group (Group 1) for the PAN08 ※ Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node ID allocated by Z-Wave Controller means exclusion. ※ Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller. LED Indication To distinguish what mode the PAN08 is in, view from the LED for identification. State TypeLED Indication Motor activate No matter up or down, close or open, Led will flash every second while Motor activate. No node IDUnder normal operation, when the PAN08 has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or Include button, it will stop flashing temporarily. However, after disconnect and reconnect the PAN08, the LED will flash on and off alternately at 2-second intervals. 2 OverloadWhen overload state occurs, the PAN08 is disabled of which LED flashes on and off alternately at 0.5 second intervals. Overload state can be cleared by disconnect and reconnect the PAN08 to the main power Choosing a Suitable Location 1.Do not locate the PAN08 facing direct sunlight, humid or dusty place. 2.The suitable ambient temperature for the PAN08 is 0°C~40°C. 3.Do not locate the PAN08 where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc. 4.After putting it into use, the body of PAN08 will become a little bit hot of which phenomenon is normal. Installation and operation 1.put the in wall PAN08 into a wall box and connect the AC power wire L,N to PAN08 connector L, N. 2.Connect the wall switch to the PAN08 as Fig1 . 3.It is important to carry out a shutter calibration process before you control the shutter to move. Press inclusion button over 3 seconds and release before the 6th second, the roller shutter controller will start the shutter calibration process. The process is composed of three continue stages. The shutter move to the TOP in first stage, and move to the BOTTOM in second stage, and move to the TOP again in third stage. Then PAN08 will know the total range of UP and DOWN. 4.During the shutter calibration process, any emergencies happen you can press and release the include button to stop the process 5.If user found the direction is reverse, this may because the wrong connection of NC and NO to the motor, please change NC and NO connection and execute calibration process again. 3 6.To manually switch up and down of the shutter, simply press S1 or S2 . 7.PAN08 built in meter function and can read the Watt , KWh, V(Voltage), I(Current) , PF(Power Factor) of the load by using Z-Wave command class, user can set a threshold watt to get the warning caused by abnormal operation 8.PAN08 have overload protection function, and can help to prevent short circuit caused by load. Programming 1. Basic Command Class The PAN08 will respond to BASIC and BINARY commands that are part of the Z-Wave system. 1.1BASIC_GET When PAN08 receive Basic Set Command , it w…

Text truncated - open the document above for the full version.

Cover Letter(s)

RF_160, Issue 02 Philio Technology Corporation Declaration of Authorization We Name: Philio Technology Corporation  .   Address: 8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C)  City: New Taipei  .  .... Country: Taiwan(R.O.C)  . Declare that: Name Representative of agent: Gene Chang (1) Agent Company name: QuieTek Corp. Address: Fl.2, No.345, Xin-hu 2 nd Rd., Nei-hu District City: Taipei Country Taiwan is authorized to apply for Certification of the following product(s): Product description: In wall Switch FCC ID: RHHPAN08 Trademark: on our behalf. Date:  2013/07/19  ..  .. City:  New Taipei City  .. Name:  JAMES HUANG  .. (2) Function:  CEO  Signature: Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.

External Photos

Report No.: 136342R-RFUSP25V01 Page : 1 of 8 Attachment 2 : EUT Detailed Photographs (1) EUT Photo (2) EUT Photo

ID Label/Location Info

Philio Technology Corporation FCC ID.: RHHPAN08 8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C) Tel : 886-229088952 FCC ID Label

ID Label/Location Info

Philio Technology Corporation FCC ID.: RHHPAN08 8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C) Tel : 886-229088952 The FCC ID Label will be placed on the equipment as shown in the photograph below.

Internal Photos

Report No.: 136342R-RFUSP25V01 Page : 2 of 8 (3) EUT Photo (4) EUT Photo Antenna Report No.: 136342R-RFUSP25V01 Page : 3 of 8 (5) EUT Photo (6) EUT Photo Report No.: 136342R-RFUSP25V01 Page : 4 of 8 (7) EUT Photo (8) EUT Photo Report No.: 136342R-RFUSP25V01 Page : 5 of 8 (9) EUT Photo (RF Module) (10) EUT Photo Report No.: 136342R-RFUSP25V01 Page : 6 of 8 (11) EUT Photo (12) EUT Photo Report No.: 136342R-RFUSP25V01 Page : 7 of 8 (13) EUT Photo (14) EUT Photo Report No.: 136342R-RFUSP25V01 Page : 8 of 8 (15) EUT Photo (16) EUT Photo

Test Report

Report No. 136342R-RFUSP25V01 Page : 1 of 29 FCC Test Report Product Name In wall Switch Model No. PAN08-2 FCC ID. RHHPAN08 Applicant Philio Technology Corporation Address 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C) Date of Receipt Jun. 20, 2013 Issued Date Jul. 08, 2013 Report No. 136342R-RFUSP25V01 Report Version V1.0 The Test Results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. This report must not be used to claim product endorsement by TAF or any agency of the U.S. Government Report No. 136342R-RFUSP25V01 Page : 2 of 29 Test Report Certification Issued Date: Jul. 08, 2013 Report No. : 136342R-RFUSP25V01 Product Name In wall Switch Applicant Philio Technology Corporation Address 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C) Manufacturer Philio Technology Corporation Model No. PAN08-2 FCC ID. RHHPAN08 EUT Rated Voltage AC 90~240V, 47~63Hz EUT Test Voltage AC 120V/60Hz Trade Name Applicable Standard FCC CFR Title 47 Part 15 Subpart C: 2012 ANSI C63.4: 2003, ANSI C63.10: 2009 Test Result Complied The Test Results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. This report must not be used to claim product endorsement by TAF or any agency of the U.S. Government Documented By : ( Senior Adm. Specialist / Jinn Chen ) Tested By : ( Engineer / Vincent Chu ) Approved By : ( Manager / Vincent Lin ) Report No. 136342R-RFUSP25V01 Page : 3 of 29 TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION................................................................................................................4 1.1. EUT Description ......................................................................................................................................4 1.2. Operation Description ..............................................................................................................................5 1.3. Tested System Details ..............................................................................................................................6 1.4. Configuration of Test System...................................................................................................................6 1.5. EUT Exercise Software............................................................................................................................6 1.6. Test Facility..............................................................................................................................................7 2. Conducted Emission ..............................................................................................................................8 2.1. Test Equipment ........................................................................................................................................8 2.2. Test Setup .................................................................................................................................................8 2.3. Limits .......................................................................................................................................................9 2.4. Test Procedure..........................................................................................................................................9 2.5. Uncertainty...............................................................................................................................................9 2.6. Test Result of Conducted Emission .......................................................................................................10 3. Radiated Emission ...............................................................................................................................12 3.1. Test Equipment ......................................................................................................................................12 3.2. Test Setup ...............................................................................................................................................13 3.3. Limits .....................................................................................................................................................14 3.4. Test Procedure........................................................................................................................................15 3.5. Uncertainty.............................................................................................................................................15 3.6. Test Result of Radiated Emission ..........................................................................................................16 4. Band Edge.............................................................................................................................................22 4.1. Test Equipment ......................................................................................................................................22 4.2. Test Setup ...............................................................................................................................................23 4.3. Limit.......................................................................................................................................................23 4.4. Test Procedure........................................................................................................................................24 4.5. Uncertainty.............................................................................................................................................24 4.6. Test Result of Band Edge................................................................................…

Text truncated - open the document above for the full version.

Test Report

Comment reply for FCC ID: RHHPAN08 _ ATCB014262 Please see my new comments below: 1. I n the submitted test report for quasi-peak radiated emission measurements below 1000 MHz on the fundamental emission, please demonstrate that the pulse repletion frequency (PRF) of pulsed emissions from this transmitter was greater than 20 Hertz in accordance with the note at the end of Section 15.35(a) of the FCC Rules. No information was provided on the transmitted modulation from this device. For quasi-peak results to be acceptable below 1000 MHz, the PRF of any signal must be greater than 20 Hertz. Otherwise peak detector results must be submitted. ANS: Please sees figure as below, because the duty c ycle=100%, Peak detector and quasi-peak results are almost same, refer to test report p15-17. So we did not change measurement value only noted quasi-peak change to peak detector shown on the report.

Test Setup Photos

Report No.: 136342R-RFUSP25V01 Page : 1 of 4 Attachment 1: EUT Test Setup Photographs Front View of Conducted Test Back View of Conducted Test Report No.: 136342R-RFUSP25V01 Page : 2 of 4 Front View of Radiated Test Back View of Radiated Test Report No.: 136342R-RFUSP25V01 Page : 3 of 4 Front View of Radiated Test (Horn) Back View of Radiated Test (Horn) Report No.: 136342R-RFUSP25V01 Page : 4 of 4 A little distance EUT

Contact Information

Applicant

JAMES HUANG(CEO)
[email protected]886-229088952Fax: 886-229088652

Technical Contact

QuieTek CorporationSabina Chen
[email protected]886-2-8601-3788

No. 5-22, Rueishu Keng, · New Taipei City · Taiwan

Test Firm

DEKRA TESTING AND CERTIFICATION CO., LTD. LinKouMirenda Liao
[email protected]+886-2-2602-7968Fax: +886-2-2602-3286

Technical Specifications

#Rule PartsFrequency RangePower Output
115C908.42 MHz - 908.42 MHz-
Confidentiality
Long Term

Other Applications from Philio Technology Corporation

Smart Energy In Wall Meter - FCC ID RHHPAB01 - Philio Technology Corporation
RHHPAB01

Smart Energy In Wall Meter

Nov 30, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Smart energy plug in switch - FCC ID RHHPAN15 - Philio Technology Corporation
RHHPAN15

Smart energy plug in switch

May 13, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Smart Color Button - FCC ID RHHPSR04 - Philio Technology Corporation
RHHPSR04

Smart Color Button

May 05, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Flood Multi Sensor - FCC ID RHHPAT02 - Philio Technology Corporation
RHHPAT02

Flood Multi Sensor

Apr 01, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Z-Wave Smoke Sensor - FCC ID RHHPSG01 - Philio Technology Corporation
RHHPSG01

Z-Wave Smoke Sensor

Jan 27, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter