S8L-AA190045RRH 2x45W 1900MHz AA190045 RF151032

Andrew Corporation, Base Station Subsystems Group
RRH 2x45W 1900MHz AA190045 RF151032 - FCC ID S8L-AA190045 - Andrew Corporation, Base Station Subsystems Group
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Jul 17, 2013
Application Purpose
Original Equipment
Date of Application
Jul 17, 2013
Equipment Note
RRH 2x45W 1900MHz AA190045 RF151032
Frequency Range
1930.00000000 - 1995.00000000
Company
Andrew Corporation, Base Station Subsystems Group
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Mounting Kits For Wide Panel Antennas BSAMNT Series: Mounting systems for installations (60-115mm pipe diameter) for heavy duty applications cylindrical pipe Installation Instructions Andrew Institute offers installation training. Bulletin 639825-1 • Revision B • March 2013 Page 1 of 2 WSHR,LK,SPLT,M12,STL,GALV Pre-assembly of Downtilt Brackets Top / Middle Mount Installations 4 (fully collapsed position) 14 EA Part Lists • Bracket edges parallel to each other. 10 M10 bolt M12 bolt 14 BOLT,CARRIAGE,M12 X 200,STL,GALV4 M10 bolt be configured in pre-assembly position (fully collapsed). 9 9108 12 CRITICAL: For initial installation to pipe, downtilt brackets must 13 1 8 2 11 EA ITEM NO.DESCRIPTIONQTYU/M 1PIPECLAMP BRACKET, NO FLANGE2EA 2PIPECLAMP BRACKET, SHORT FLANGES2EA 3NOTCHED BRACKET1EA 4BRACKET1EA 5SCR,HCS,HEX,M8X25,STL,GALV4EA 6WSHR,LK,SPLT,M8,STL,GALV4EA 7TWO HOLE PLATE, 8mm X 1.25 PITCH2EA 8NUT,HEX,M10,STL,GALV12EA 9WSHR,LK,SPLT,M10,STL,GALV6EA 10SCR,HCS,HEX,M10X40,STL,GALV6EA 11NUT,HEX,M12,STL,GALV8EA 12WSHR,FLT,M12,13X28X2.5,STL,GALV4EA 13 MAXIMUM TORQUE M815N.m (11ft.lbs) M1037N.m (27ft.lbs) M1258N.m (43ft.lbs) ATTENTION: Insert M12 bolts and M12 flat washers into bracket with tabs prior to attaching bracket to antenna. 6 4 7 3 two hole plate 5 M8 bolt 15N.m (11ft.lbs) 37N.m (27ft.lbs) M12 Bottom Mount Installation M10 adjust antenna angle use inclinometer to Adjusting Antenna Tilt (loosen only) M10 pivot bolt 58N.m (43ft.lbs) (loosen only) M10 pivot bolt M10 bolt (loosen only) center location M8 pivot bolt M12 bolt (remove to adjust tilt) perimeter location DETAIL A M10 pivot bolt (loosen only) 12 11 M8 adjuster bolt 13 1 9108 14 2 MAXIMUM TORQUE M8 MAXIMUM TORQUE M1037N.m (27ft.lbs) M1258N.m (43ft.lbs) (Continued from page 1) BSAMNT Mounting Kit CommScope • ATTENTION: Insert M12 bolts and M12 flat washers into bracket with tabs prior to attaching bracket to antenna. M10 pivot bolt Bulletin 639825-1 • Revision B • March 2013 Page 2 of 2 (loosen only) International: +1-779-435-6500, Option 1 A Customer Support Center • Retighten all bolts. • Reinstall adjuster bolts. any specifications or warranties relating to Andrew products or services. (use inclinometer) • Adjust antenna angle. • Remove adjuster bolts. not remove) Loosen pivot bolts . (do North America: +1-800-255-1479, Option 1 Email: [email protected] Visit our Web site at www.commscope.com or contact your local sales representative for more information. © 2012 CommScope, Inc. All rights reserved. Andrew is a trademark of CommScope. All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement applicable safety precautions as shown on this page. when the field installation is performed. Follow all It is recommended that transmit power be turned off results of improper or unsafe installation practices. ladder. is in the area. Do not use metal day or when lightning or thunder Do not install on a wet or windy CommScope disclaims any liability or responsibility for the electrocute you. Assume any wire or line can and guy wires look the same. Power lines, telephone lines, rubber gloves. including a long-sleeved shirt and heels. Wear protective clothing Wear shoes with rubber soles and Do not install near power lines. maintenance, and condition of equipment. SAFETY NOTICE The installation, maintenance, or removal of an antenna requires qualified, experienced personnel. CommScope installation instructions are written for such installation personnel. Antenna systems should be inspected once a year by qualified personnel to verify proper installation, www.commscope.com/andrew CommScope RF Safety Warning: Although the final configurations are determined at time of licensing, it is important that the antenna selection and installation do not exceed equipment authorization and adequate separation distance is maintained. One of investigated configurations is that RRH 2x45 MHz has an output EIRP of 5.2kW and a minimum RF safety separation distance of 6.4 meters with max gain 17.5 dBi.

Users Manual

2x45W RRH for E-UTRAN Band 25 (FCC ID: S8L-AA190045) Product Description Key Specifications: Base-Station Interface: CPRI High Speed Digital I/O (PCS LTE Traffic + Control) 2 Duplexed Antenna Ports: Tx Frequency Range: 1930-1995MHz; 45WRF (+46.5dBm) max each port; Rx Frequency Range: 1850-1915MHz; sensitivity -101.5 dBm (10MHz LTE) And 2 RX Ports: Rx Frequency Range: 1850-1915MHz; sensitivity -101.5 dBm (10MHz LTE) Power Input: -48VDC nominal; Load Current 8.4 ADC (with 2x45WRF) 2x45W 1900MHz RRH – Interface Ports (Bottom) 8) DC Power Port: Input. -48V (-38.5V to 58V) With Tx1=Tx2=45W, 8A 2.2A after boot-up 3 . 0 A b i a s O N , n o R F 7 ) Et h e r n e t M a in t e n a n ce Port: Input/Output 10/100 Base-T 5) Tx2 Monitor Port: Output -40dBc sample of RF on Tx2/Rx2 port 6) Tx1 Monitor Port: Output -40dBc sample of RF on Tx1/Rx1 port 2) Secondary CRPI Port Serial Digital Traffic & Control Input/Output. (accepts optical or electrical SFP modules) Supported Data rates: Rate 2: 1.2288Gbps Rate 3: 2.457.6Gbps R a te 4 : 3 . 07 20 G b p s Status LED 1) External alarms port 3) Primary CPRI Port 4) Serial RS232 Connection JTAG DSP 2x45W 1900MHz RRH – Interface Ports (Top) 10) AISG Port Input/Output, RS485 signaling +24VDC/2A 11) Rx3 Port: Up-link RF In: 1850-1915MHz; -102dBm to -40dBm 13) Tx2 /Rx2 Port: Duplexed Antenna Ports Input/Output. Down-link RF Out: 1930-1995MHz; +46.5 dBm (45W each) Up-link RF In: 1850-1915MHz; -102dBm to -40dBm 12) Tx1/Rx1 Port: Duplexed Antenna Ports Input/Output. Down-link RF Out: 1930-1995MHz; +46.5 dBm (45W each) Up-link RF In: 1850-1915MHz; - 102dBm to - 40dBm 9) Rx4 Port: Up-link RF In: 1850-1915MHz; -102dBm to -40dBm FCC Statement/ FCC ID: S 8L-AA190045 This device complies with Part 2, 15 and 24 of the FCC Rules. O peration is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning Changes of modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. RF exposure compliance is addressed at the time of licensing, as r equired by the responsible FCC Bureau(s), including antenna co- location requirements of 1.1307(b)(3).

Cover Letter(s)

EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 6 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 DC voltages and DC currents per 2.1033(c)(8) The input supply to the Remote Radio Head (RRH) was set at -48 Volts DC. The RF power output was measured with the indicated voltage and current applied into the RRH. RRH 2x45W 1900MHz AA190045 RF Output, DC Current and RF Input Power are all average values. Active Mode: Measured Rated RF output @ each Tx port: 46.5dBm ( 45W) Measured DC voltage: -48.0V Measured DC current: 8.05A. Standby Mode: Measured Minimum RF output: -16.0dBm (0.025mW) Measured DC voltage: -48.0V Measured DC current: 1.05A Tune-up procedure per 2.1033(c) (9) There are no user accessible adjustments or tuning in this EUT. All necessary adjustments and tuning are performed during manufacture of the product. Any adjustments or tuning after service or repair are done as part of that process as special equipment is required to perform such adjustments.

External Photos

EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 162 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 RRH 2x45W 1900MHz RF151032 with antenna assembly EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 163 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 164 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 165 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 166 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288

ID Label/Location Info

EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 158 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 9. FCC ID Labeling FCC ID Label (The statement may be shown in its User Manual) FCC Label Location (side of EUT) FCC ID: S8L-AA190045 This device complies with Part 2, 15 & 24 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; and, (2) This device must accept any interference received, including interference that may cause undesired operation. FCC ID Label

RF Exposure Info

EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 158 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 10. Maximum Permissible Exposure MPE estimate is given per 2.1091 of FCC Rules: Calculation Equation: S d GP 20 10 282.0  u Where, P--max. Output Power, G—Antenna Gain and S—Power Density Factor from §1.1310. From §1.1310 Table 1 (B), for Public S = 1.0 mW/cm 2 , for Professional, S = 5.0 mW/cm 2 Plug all three items into the equation, and yields, Power Density MPE Limit (mW/ cm 2 ) Max. Output Power (dBm) Max. Antenna Gain (dBi) MPE Distance (cm) 1.0 49.68 17.5 644.5 NOTE: For mobile or fixed location transmitters, the minimum separation distance is 20 cm, even if calculations indicate that the MPE distance would be less.

Test Report

Electromagnetic Emission Compliance Test Report Equipment Under Test (EUT) Remote Radio Head 2x45W 1900MHz AA190045 RF151032 Applicant Andrew Corporation In Accordance With FCC Part 2 and Part 24, Subpart E Test by Advanced Compliance Laboratory, Inc. 6 Randolph Way Hillsborough, New Jersey 08844 Authorized by Wei Li Lab Manager Signature Date June 28, 2013 AC Lab Report Number 0048-130617-01 The test result in this report is supported and covered by the NVLAP accreditation. Lab Code:200101-0 Advanced Compliance Laboratory 6 Randolph Way Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 2 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Index Section 1. Summary of Test Results ..................................................................... 3 Section 2. General Equipment Specification ....................................................... 5 Section 3. RF Output Power .................................................................................... 8 Section 4. Occupied Bandwidth ........................................................................... 20 Section 5. Spurious Emissions at Antenna Terminals .................................... 76 Section 6. Field Strength of Spurious ............................................................... 149 Section 7. Frequency Stability ............................................................................ 154 Section 8. Test Equipment List ........................................................................... 156 Section 9. FCC ID Labeling .................................................................................. 157 Section 10. Maximum Permissible Exposure ....................................................158 Section 11. Setup Photos ......................................................................................159 Section 12. EUT Photos .........................................................................................161 EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 3 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 1. Summary of Test Results Manufacturer: Andrew Corporation Product Name: RRH 2x45W 1900MHz AA190045 Parts No.: RF151032 General: All measurements are traceable to national standards These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 24, Subpart E. New Submission Production Unit Class II Permissive Change Pre-Production Unit THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED. THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE. “See Summary of Test Data” NVLAP LAB CODE: 200101-0 Advance Compliance Laboratory, Inc. authorizes the above named company to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Advance Compliance Laboratory, Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 4 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Summary of Test Data RF Power Output 24.232(a) 1640W EIRP Complies** Occupied Bandwidth (Digital) 2.1049(i) --- Complies Spurious Emissions at Antenna Terminals 24.238 -13 dBm Complies Field Strength of Spurious Emissions 24.238 -13 dBm E.I.R.P. Complies Frequency Stability 24.235 0.05 ppm Complies ** See page 10. The estimated uncertainty of the test result is given as following. The method of uncertainty calculation is provided in Advanced Compliance Lab. Doc. No. 0048-01-01. Prob. Dist. Uncertainty(dB) Uncertainty(dB) Uncertainty(dB) 30-1000MHz 1-6.5GHz Conducted Combined Std. Uncertainty u c norm. ±2.36 ±2.99 ±1.83 Wei Li Date: June 28, 2013 Lab Manager Advanced Compliance Lab EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 5 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 2. General Equipment Specification Supply Voltage -48VDC ( extended -39.5VDC to -57VDC) Frequency Range PCS Broad Band TX/ 1930 – 1995 MHz RX/ 1850 – 1915 MHz Modulation LTE OFDMA in FDD WCDMA GSM EDGE TDMA Type of Emissions F9W F9W GXW G7W DXW Rated Power 45W (46.5dBm) average @ each Tx Port Total two Tx Ports presented with total combined output power: 90W (49.5dBm) Operating Power 45W average / Single Carrier 22.5W/ Carrier (2 Carriers) Channel BW /Output Impedance 5MHz, 10MHz, 20MHz 50ohm Frequency Translation F1-F1 F1-F2 N/A Software Duplexer Change Full Band Coverage DC voltages and DC currents per 2.1033(c)(8) The input supply to the Remote Radio Head (RRH) was set at -48 Volts DC. The RF power output was measured with the indicated voltage and current applied into the RRH. RRH 2x45W 1900MHz AA190045 RF Output, DC Current and RF Input Power are all average values. Active Mode: Measured Rated RF output @ each Tx port: 46.5dBm (45W) Measured DC voltage: -48.0V Measured DC current: 8.05A. Standby Mode: Measured Minimum RF output: -16.0dBm (0.025mW) Measured DC voltage: -48.0V Measured DC current: 1.05A EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 6 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Tune-up procedure per 2.1033(c) (9) There are no user accessible adjustments or tuning in this EUT. All necessary adjustments and tuning are performed during manufacture of the product. Any adjustments or…

Text truncated - open the document above for the full version.

Test Setup Photos

EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 160 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 11. Setup Photos Conducted Measurements at Antenna TX Port EUT: RRH 2x45W 1900MHz AA190045 Model: RF151032 Report Number: 0048-130617-01 Page 161 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Field Strength of Spurious

Contact Information

Applicant

Gerald Reynolds(Director, Quality)
[email protected]972-952-9700Fax: 972-952-0000

Test Firm

Advanced Compliance LaboratoryWei Li
[email protected]908-927-9288Fax: 908-927-0728

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
324E1.93 GHz - 2.00 GHz93.5 W17M9F9W0.004 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is total conducted output power across two RF antenna ports. Device supports single carrier (45W per port) and multi-carrier (two carriers at 22.5W per carrier per port) operations. The antennas used for this transmitter must be professionally installed and have an antenna gain less than 17.5 dBi. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). With 17.5 dBi antenna gain, the minimum separation distance between the antenna and any human body should be greater than 6.4 meters to meet FCC RF exposure requirements.

Other Applications from Andrew Corporation, Base Station Subsystems Group

800MHz 2x50W RRH RF101017 - FCC ID S8L-RRH800L1 - Andrew Corporation, Base Station Subsystems Group
S8L-RRH800L1

800MHz 2x50W RRH RF101017

Sep 09, 2011

Equipment Class

AMP - Amplifier
Remote Radio Head RRH 2x40W 700MHz RF101002 - FCC ID S8L-RRH700L1 - Andrew Corporation, Base Station Subsystems Group
S8L-RRH700L1

Remote Radio Head RRH 2x40W 700MHz RF101002

Jun 21, 2010

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
1960 CDMA Multiple Carrier Power AmplifierRF100978 - FCC ID S8L-100978MCPA - Andrew Corporation, Base Station Subsystems Group
S8L-100978MCPA

1960 CDMA Multiple Carrier Power AmplifierRF100978

Apr 01, 2008

Equipment Class

AMP - Amplifier
OneBase Micro Cabinet Cell Extender OBE-1900-2411 - FCC ID S8L-OBEMICRO1 - Andrew Corporation, Base Station Subsystems Group
S8L-OBEMICRO1

OneBase Micro Cabinet Cell Extender OBE-1900-2411

Mar 30, 2008

Equipment Class

AMP - Amplifier
HPRM850 Amplifier RF100595/NTN065JA - FCC ID S8L-100595HPRM - Andrew Corporation, Base Station Subsystems Group
S8L-100595HPRM

HPRM850 Amplifier RF100595/NTN065JA

Feb 22, 2007

Equipment Class

AMP - Amplifier