Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Andrew Corporation 40 Technology Drive Warren, NJ U.S.A. 07059 Tel: (908) 546-4600 Andrew Wireless Solutions – A Commscope Company Proprietary – Use Pursuant to Company Instructions 1 SUBJECT: AUTHOR: OneBase™ MicroCabinet Cell Extender OBE-1900-2411 Chris Zappala Operational Instruction 03/06/08 FCC ID: S8L-OBEMICRO1 Version 1.0 Industry Canada ID: 2237F-OBEMICRO1 Overview: The OneBase™ MicroCabinet Cell Extender OBE-1900-2411 system is small, self- contained cabinet unit intended to be used in a single-sector application for cell site signal boosting. The system provides high-power, mixed-mode RF front-end functionality of signal amplification and conditioning for both uplink and downlink cellular base station signals. The OneBase™ MicroCabinet Cell Extender OBE-1900-2411 system can be used for a variety of air interfaces including GSM/EDGE, CDMA, WCDMA interfaces. System Specifications: Parameter Specification Comment Frequency Band 1900 MHz PCS (Personal Communications Services) Band Operational Bandwidth 60 MHz Rx: 1850-1910 MHz Tx: 1930-1990 MHz Operating Temperature -40°C to +50°C Outdoor Application: Cold start –40°C, Operational spec at –20°C Output Power 116 Watts System output power utilizing MSA1900-135 Andrew Corporation 40 Technology Drive Warren, NJ U.S.A. 07059 Tel: (908) 546-4600 Andrew Wireless Solutions – A Commscope Company Proprietary – Use Pursuant to Company Instructions 2 Parameter Specification Comment Power Draw 1.3 Kilowatts At maximum power output, in overdrive Supported Output Power 40 Watts/carrier for WCDMA or CDMA 25 Watts/carrier for GSM or EDGE Typical power-per-carrier at the antenna port. In-Band emissions -13 dBm/MHz FCC emissions specification Transmit Path Gain +3 dB +/- 6 dB Variable gain adjustment range Receive Path Insertion Loss 2.0 dB Typical Bypass Loss 0.75 dB Maximum Functional Blocks: The following system modules are capable of being replaced in the field using common tools used by field-support personnel. The primary interfaces of the field replaceable modules are blind-mate type connections or standard cable connections to appropriate interfaces within the cabinet assembly. • Multi-carrier Power Amplifier (MCPA) Module • Input Tray Module • Filter Module • Rectifier Module • Bypass Module • Fan Tray Assembly and associated fan controller Andrew Corporation 40 Technology Drive Warren, NJ U.S.A. 07059 Tel: (908) 546-4600 Andrew Wireless Solutions – A Commscope Company Proprietary – Use Pursuant to Company Instructions 3 System Diagram & Cabinet Layout: Andrew Corporation 40 Technology Drive Warren, NJ U.S.A. 07059 Tel: (908) 546-4600 Andrew Wireless Solutions – A Commscope Company Proprietary – Use Pursuant to Company Instructions 4 Alarms: The OneBase™ MicroCabinet Cell Extender OBE-1900-2411 system characterizes alarm severity according the following table. ALARM CATEGORY SEVERITY Minor Conditions that do not immediately affect system operation, but lead to more serious problems if ignored (e.g. fan failure). Major Conditions that directly affect amplifier operation (e.g. reduced gain), but allow the system to continue operating. Critical Conditions which result in sector shutdown, preventing any further cellular call traffic. MCPA LEDs: The MCPA module has three (3) LED indicators on the front panel and labeled as follows: o “ALARM” (Red) o “WARNING” (Yellow) o “ACTIVE” (Green) The following chart summarizes the various LED conditions, alarm severity, and possible failure modes. Andrew Corporation 40 Technology Drive Warren, NJ U.S.A. 07059 Tel: (908) 546-4600 Andrew Wireless Solutions – A Commscope Company Proprietary – Use Pursuant to Company Instructions 5 MCPA LEDs MCPA LEDs Status Alarm Severity Possible Failure Modes Green: “ON” Yellow: “ON” Red: “ON” Initial Power-up of MCPA. NONE LEDs all “ON” simultaneously for about 2 seconds. Green: “ON” Normal Operation NONE Green: “ON” Yellow: “ON” Minor 1. MCPA high internal temperature (approximately between 80°C and 90°C). 2. MCPA values on “Micro MCPA Live Display” software indicating: --Poor Return Loss (3-8 dB) --Poor VSWR (2.32 - 5.85) Yellow: “ON” Major 1. RF Overdrive (gain reduced) 2. DC voltage out of normal range Red: “ON” Critical 1. MCPA internal failure 2. RF Overdrive (> 10 dB) 3. MCPA high internal temperature (above approximately 90°C). 4. MCPA values on “Micro MCPA Live Display” software indicating: --Poor Return Loss (0-3 dB) --Poor VSWR (above 5.85) Andrew Corporation 40 Technology Drive Warren, NJ U.S.A. 07059 Tel: (908) 546-4600 Andrew Wireless Solutions – A Commscope Company Proprietary – Use Pursuant to Company Instructions 6 Fan Controller LEDs: Fan Controller Board LED Status Alarm Severity Possible Failure Modes LED 1, LED 2, LED 5 DISABLED NONE LEDs 3, 4, 6: GREEN Normal Operation NONE LED 3: RED “Fan 1” failed. LED 4: RED All three temperature-sensing thermistors on the controller are either shorted or open, resulting in no valid thermistor output. LED 6: RED Fan #2 failed. Dry Contact Summary Alarms: ALARM Possible Failure Modes Door Alarm Intrusion Environmental Alarm (ENV) 1. Fan controller loses power. 2. Fan is spinning at less than 1900 RPM. 3. All three thermistors on the contnroller are either shorted or open, resulting in no valid thermistor output. 4. One fan has failed. 5. Both fans have failed. Rectifier Alarm” Rectifier failure HH Alarm” DISABLED Minor MPCA Minor Failure: See “Table 10”. Major MPCA Major Failure: See “Table 10”. Critical MPCA Critical Failure: See “Table 10”. Andrew Corporation 40 Technology Drive Warren, NJ U.S.A. 07059 Tel: (908) 546-4600 Andrew Wireless Solutions – A Commscope Company Proprietary – Use Pursuant to Company Instructions 7 Installation and Operation Set-Up The OneBase™ MicroCabinet Cell Extender OBE-1900-2411-1900 Band is shipped from the factory with all necessary internal cables and wiring. Each unit is factory tested to meet overall product requirements. As such, installation of the Micro-1 Cabinet involves the …
Text truncated - open the document above for the full version.
Andrew Corporation, FCC ID: S8L-OBEMICRO1, Assessment NO.: AN08T7667, Notice#1 Inbox X Active X from [email protected] to Wei Li <[email protected]>, cc [email protected], date Mon, Mar 24, 2008 at 1:51 PM subject Andrew Corporation, FCC ID: S8L-OBEMICRO1, Assessment NO.: AN08T7667, Notice#1 hide details 1:51 PM (22 hours ago) Reply Hi Wei, Please accept my apology that this one took so long. We had two reviewers away last week so there was a lot of work. The review of this application is complete. The only issue is that the contact in FCC database is Vince Dezuzio. Authorization and confidentiality letters are signed by Christoper Zappala. The authorization letter must be signed by person named in FCC database. Other letters must be signed by the contact named in teh FCC database, or by person(s) named in the authorization letter. Please either revise the signature on the letter(s) or update the contact information in the FCC database. Also please be advised that we may need to change the FCC equipment code from TNB to AMP. I am discussing this with Mike, but I don't think there is anything additional needed for this part. The IC application is complete as well and the grant will be issued with this one. I also see a new application just entered. It should not take long. The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information within 30 days of the original e-mail date may result in application dismissal and forfeiture of the filing fee. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the e-mail address listed below the name of the sender. Best regards, Tim Dwyer Technical Reviewer Reply Reply to all Forward from W Li <[email protected]> to [email protected], date Tue, Mar 25, 2008 at 8:41 AM subject Re: Andrew Corporation, FCC ID: S8L-OBEMICRO1, Assessment NO.: AN08T7667, Notice#1 hide details 8:41 AM (3 hours ago) Reply Hi, Tim. THANKS A LOT! I'll ask Andrew to issue another letters today. For confidentiality letter, you mean I can sign it since I am from ACL (authorized by Andrew)? Regards, Wei - Show quoted text - - Show quoted text - Reply Reply to all Forward http://mail.google.com/mail/?ui=2&view=bsp&ver=ymdfwq781tpu http://mail.google.com/mail/?ui=2&view=bsp&ver=ymdfwq781tpu (1 of 2)3/25/2008 12:02:55 PM http://mail.google.com/mail/?ui=2&view=bsp&ver=ymdfwq781tpu from Tim Dwyer <[email protected]> to W Li <[email protected]>, date Tue, Mar 25, 2008 at 9:36 AM subject Re: Andrew Corporation, FCC ID: S8L-OBEMICRO1, Assessment NO.: AN08T7667, Notice#1 mailed-by gmail.com hide details 9:36 AM (2 hours ago) Reply Hi Wei, Yes, once you have the authorization letter signed by the contact listed at FCC you can sign other letters. The authorization letter can list more than one name so if others at Andrew or ACL will need to sign letters then show all of them on the authorization letter. There is still some question at FCC if it is ok to list a company name (e.g ACL) so it is best to list names of specific individual(s) for now. FCC has shown a recent interest in this and will take action, possibly dismissing grants, if we do not follow this strictly. Best regards, Tim - Show quoted text - Reply Forward from W Li <[email protected]> to Tim Dwyer <[email protected]>, date Tue, Mar 25, 2008 at 11:59 AM subject Re: Andrew Corporation, FCC ID: S8L-OBEMICRO1, Assessment NO.: AN08T7667, Notice#1 hide details 11:59 AM (2 minutes ago) Reply Hi, Tim. Here are the revised letters. Regards, Wei - Show quoted text - - Show quoted text - 2 attachments — Download all attachments FCCAuthorltr2.pdf 53K View as HTML Download FCCConfidltr1.pdf 30K View as HTML Download http://mail.google.com/mail/?ui=2&view=bsp&ver=ymdfwq781tpu (2 of 2)3/25/2008 12:02:55 PM
EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 95 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 OBE-1900-2411 External -Front EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 96 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 OBE-1900-2411 External -Rear EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 97 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 OBE-1900-2411 External –Front Cover Open EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 98 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 OBE-1900-2411 External –Rear Cover Open
EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 88 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 10. FCC ID Labeling FCC ID Label (The statement may be shown in its User Manual) F C C Affix FCC label at the top left Wall as shown. FCC Label Location FCC ID: S8L-OBEMICRO1 This device complies with Part 15,24 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference. an d (2) this device must accept any interference received, including interference that may cause undesire d operation.
EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 89 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 11. Maximum Permissible Exposure MPE estimate is given per 2.1091 of FCC Rules: Calculation Equation: S d GP 20 10 282.0 + ×= Where, P--max. Output Power, G—Antenna Gain and S—Power Density Factor from §1.1310. Plug all three items into the equation, and yields, Power Density MPE Limit (mW/ cm 2 ) Output Power (dBm) Server Antenna Gain (dBi) Donor Antenna Gain (dBi) Server MPE Distance (cm) Donor MPE Distance (cm) NOTE: For mobile or fixed location transmitters, the minimum separation distance is 20 cm, even if calculations indicate that the MPE distance would be less. N/A FOR THIS CASE ----AMPLIFIER SYSTEM ONLY, NO ATENNNA PRESENT.
Electromagnetic Emission Compliance Test Report Equipment Under Test (EUT) OneBase™ Micro-Cabinet Cell Extender OBE-1900-2411 Applicant Andrew Corporation In Accordance With FCC Part 24, Subpart E Test by Advanced Compliance Laboratory, Inc. 6 Randolph Way Hillsborough, New Jersey 08844 Authorized by Wei Li Lab Manager Signature Date February 28, 2008 AC Lab Report Number 0048-071120-01 The test result in this report is supported and covered by the NVLAP accreditation. Lab Code:200101-0 Advanced Compliance Laboratory 6 Randolph Way Hillsborough, NJ 08844 Tel: (908) 927 9288 Fax: (908) 927 0728 EUT: OneBase Cell Extender FCC ID: S8L-OBEMCPA Model No.: OBE-DB-X Report Number: 0048-061009-01 Page 2 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Index Section 1. Summary of Test Results....................................................................... 3 Section 2. General Equipment Specification......................................................... 5 Section 3. RF Output Power....................................................................................... 7 Section 4. Occupied Bandwidth.............................................................................. 10 Section 5. Spurious Emissions at Antenna Terminals..................................... 36 Section 6. Field Strength of Spurious................................................................... 77 Section 7. Frequency Stability................................................................................ 83 Section 8. Out of Band Rejection........................................................................... 85 Section 9. Test Equipment List............................................................................... 87 Section 10. FCC ID Labeling.................................................................................... 88 Section 11. Maximum Permissible Exposure...................................................... 89 Section 12. Setup Photos......................................................................................... 90 Section 13. EUT Photos............................................................................................. 94 EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 3 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 1. Summary of Test Results Manufacturer: Andrew Corporation Product Name: OneBase Micro-Cabinet Cell Extender Model No: OBE-1900-2411 S/N: P001 General: All measurements are traceable to national standards These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 24. New Submission Production Unit Class II Permissive Change Pre-Production Unit THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED. THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE. “See Summary of Test Data” NVLAP LAB CODE: 200101-0 Advance Compliance Laboratory, Inc. authorizes the above named company to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Advance Compliance Laboratory, Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 4 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Summary of Test Data 22.913(a) 500W ERP N/A* RF Power Output 24.232(a) 100W EIRP Complies Occupied Bandwidth (Voice & SAT) 2.1049(i) Mask N/A* Occupies Bandwidth (Wideband Data) 2.1049(i) Mask N/A* Occupied Bandwidth (Digital) 2.1049(i) Mask Complies 22.917 -13 dBm N/A* Spurious Emissions at Antenna Terminals 24.238 -13 dBm Complies 22.917 -13 dBm N/A* Field Strength of Spurious Emissions 24.238 -13 dBm E.I.R.P. Complies 22.355 1.5 ppm N/A* Frequency Stability 24.235 0.05 ppm N/A* * These items are NOT applied to the EUT. The estimated uncertainty of the test result is given as following. The method of uncertainty calculation is provided in Advanced Compliance Lab. Doc. No. 0048-01-01. Prob. Dist.Uncertainty(dB) Uncertainty(dB) Uncertainty(dB) 30-1000MHz 1-6.5GHz Conducted Combined Std. Uncertainty u c norm. ±2.36 ±2.99 ±1.83 Wei Li Date: February 28, 2008 Lab Manager Advanced Compliance Lab EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 5 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 2. General Equipment Specification Supply Voltage 100-240Vac (27V for PA Module) Cellular N/A PCS DL/1930-1990MHz Frequency Range Modulation CDMA 2000 WCDMA GSM EDGE TDMA Output Impedance 50ohm Total Rated Power 116W (+50.64dBm) Typical Operating Power/carrier WCDMA/CDMA: 40W GSM/EDGE: 25W F1-F1 F1-F2 N/A Frequency Translation Software Duplexer Change Full Band Coverage DC voltages and DC currents per 2.1033(c)(8) The input supply to the transmitter was set at 27 Volts DC. The RF power output was measured with the indicated voltage and current applied into the final RF amplifying device(s). OBE-1900-2411 Power Amplifier RF Output, DC Current and RF Input Power are all average values. Measured Rated RF output at MicroCabinet: 50.64dBm ( 116W) Measured DC voltage: 27.0V Measured DC current: 30.3A Measured Minimum RF output at MicroCabinet: 1.32dBm (1.3mW) Measured DC voltage: 27.0V Measured DC current: 14.8A Tune-up procedure per 2.1033(c) (9) There are no user accessible adjustments or tuning in this ampli…
Text truncated - open the document above for the full version.
EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 90 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Section 12. Setup Photos RF Output Power EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 91 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Spurious Emissions at Antenna Terminal EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 92 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Occupied Bandwidth EUT: OneBase Micro-Cabinet Cell Extender FCC ID: S8L-OBEMICRO1 Model No.: OBE-1900-2411 Report Number: 0048-071120-01 Page 93 Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288 Field Strength of Spurious
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 3 | 24E | 1.93 GHz - 1.99 GHz | 116 W | F9W | Amp |

RRH 2x45W 1900MHz AA190045 RF151032
Equipment Class
PCB - PCS Licensed Transmitter
800MHz 2x50W RRH RF101017
Equipment Class
AMP - Amplifier
Remote Radio Head RRH 2x40W 700MHz RF101002
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
1960 CDMA Multiple Carrier Power AmplifierRF100978
Equipment Class
AMP - Amplifier
HPRM850 Amplifier RF100595/NTN065JA
Equipment Class
AMP - Amplifier