Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Power Monitor User’s Manual i ABOUT THIS MANUAL This manual is designed for use with the Power Monitor. Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. The information in this document is subject to change without notice. The manufacturer does not make any representations or warranties (implied or otherwise) regarding the accuracy and completeness of this document and shall in no event be liable for any loss of profit or any commercial damage, including but not limited to special, incidental, consequential, or other damage. SAFETY INSTRUCTIONS Always read the safety instructions carefully: Keep this User’s Manual for future reference Keep this equipment away from humidity If any of the following situation arises, get the equipment checked by a service technician: xThe equipment has been exposed to moisture. xThe equipment has been dropped and damaged. xThe equipment has obvious sign of breakage. xThe equipment has not been working well or you cannot get it to work according to the User’s Manual. COPYRIGHT This document contains proprietary information protected by copyright. All right are reserved. No part of this manual may be reproduced by any mechanical, electronic or other means, in any form, without prior written permission of the manufacturer. TRADEMARKS All trademarks and registered trademarks are the property of their respective owners or companies. Table of Contents 1. Introduction............................................................................................................ 1 Features ............................................................................................................................. 2 Package Contents .............................................................................................................. 2 Z-Wave .............................................................................................................................. 2 Wireless Range..................................................................................................................2 2. Installation .............................................................................................................. 3 Hardware Connection ....................................................................................................... 3 Product Description........................................................................................................... 4 Installation Requirements ................................................................................................. 4 Installing the Power Monitor ............................................................................................ 5 3. Specifications......................................................................................................... 6 4. Regulatory Compliance ......................................................................................... 7 FCC Conditions ................................................................................................................ 7 WEEE Information ........................................................................................................... 7 ii 1. Introduction This Power Monitor enables you to find out what appliances are actually worth keeping plugging in and can save your energy costs. This Power Monitor can send and receive information to and from the Z-Wave enable devices wirelessly. You can monitor the values of measurements and setup the functions in your home through PC connectivity with Z-Wave USB dongle when you are away from home. Caution: To avoid damage to the monitor, please keep from humidity and any inappropriate usage. 1 2 Features Simply plug in the wall outlet and attach the electronic appliances. Shows the operating costs of electronic appliances that plug into the power monitor. Calculates the cost of power consumed in time periods of hour, day, week, month and year. Display the values of the measurements on the remote site. Fully compatible with Z-Wave enable network that can communicate with any Z-Wave certified device. Act as a repeater that can re-transmit the Z-Wave signal to ensure the intended destination is received. Package Contents Power Monitor x1 User’s Manual x1 Z-Wave Z-Wave is a state-of-the-art wireless technology used as a standard for wireless home control. It is a next-generation wireless ecosystem that lets all your home electronics talk to each other, and to you, via a controller or gateway. It uses simple, reliable, low-power radio waves that easily travel through walls, floors and cabinets. All products featuring the Z-Wave logo are certified to work with one another. Wireless Range The Power Monitor is made wireless by Z-Wave technology. Typical range for a wireless module is approximately 100 feet. When installing the module consider an open area with little obstruction for the best signal and performance. Avoiding the obstruction between the module and controller may make a negative effect on wireless performance and range. 2. Installation Hardware Connection Z-Wave Enabled Outlet LED Indicator Inclusion / Exclusion Button Plug 3 Product Description Below is a description of button, light and plugs for the Power Monitor. LED Indicator The LED (dual color) will light red to indicate the Power Monitor accesses to electricity. When the LED flash green, it stands for Z-Wave RF under transfer/ receive status. Z-Wave Enabled Outlet This outlet is used to plug in the device you wish to detect, such as your electric appliance. Note that any device plugged into this outlet must NOT exceed 1600 watts. Inclusion / Exclusion Button When the Power Monitor has been installed, pressing the button and making an inclusion / exclusion between the Power Monitor and Controller. Wall Outlet Plug Located on the back of Power Monitor, the plug is used to plug yo…
Text truncated - open the document above for the full version.
Compliance Certification Services Inc. Report No.: T110804213 Date of Issue: August 17, 2011 A1 - 1 / 7 APPENDIX 1 - PHOTOGRAPHS OF EUT EXTERNAL PHOTOGRAPHS OF EUT Compliance Certification Services Inc. Report No.: T110804213 Date of Issue: August 17, 2011 A1 - 2
Compliance Certification Services Inc. Report No.: T110804213 Date of Issue: August 17, 2011 A1 - 3 INTERNAL PHOTOGRAPHS OF EUT Compliance Certification Services Inc. Report No.: T110804213 Date of Issue: August 17, 2011 A1 - 4 Compliance Certification Services Inc. Report No.: T110804213 Date of Issue: August 17, 2011 A1 - 5 Compliance Certification Services Inc. Report No.: T110804213 Date of Issue: August 17, 2011 A1 - 6 PCB Antenna Compliance Certification Services Inc. Report No.: T110804213 Date of Issue: August 17, 2011 A1 - 7
Compliance Certification Services Inc. FCC ID: SW8TD1030 Report No.: T110804213-RP1 Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 / 26 FCC 47 CFR PART 15 Subpart C TEST REPORT For Power Monitor Model Number: TD1030Z1 Trade Name: GOOD WAY Issued to GOOD WAY TECHNOLOGY CO., LTD. 3F, No. 135, Ln. 235, Baociao Rd., Sindian Dist., New Taipei City 231, Taiwan, R.O.C. Issued by Compliance Certification Services Inc. No.11, Wu-Gong 6th Rd., Wugu Industrial Park, New Taipei City 248, Taiwan (R.O.C.) http://www.ccsrf.com [email protected] Issued Date: August 16, 2011 Compliance Certification Services Inc. FCC ID: SW8TD1030 Report No.: T110804213-RP1 Page 2 Revision History Rev. Issue Date Revisions Effect Page Revised By 00 August 16, 2011 Initial Issue ALL Sandy Lin Compliance Certification Services Inc. FCC ID: SW8TD1030 Report No.: T110804213-RP1 Page 3 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION................................................................................................................ 4 2. EUT DESCRIPTION...................................................................................................................................... 5 3. TEST METHODOLOGY ............................................................................................................................... 6 3.1 EUT CONFIGURATION................................................................................................................. 6 3.2 EUT EXERCISE............................................................................................................................. 6 3.3 GENERAL TEST PROCEDURES...................................................................................................... 6 3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS.................................................. 7 3.5 DESCRIPTION OF TEST MODES.................................................................................................... 7 4. INSTRUMENT CALIBRATION................................................................................................................... 8 4.1 MEASURING INSTRUMENT CALIBRATION............................................................................... 8 4.2 MEASUREMENT EQUIPMENT USED .................................................................................. 8 4.3 MEASUREMENT UNCERTAINTY ........................................................................................ 9 5. FACILITIES AND ACCREDITATIONS .................................................................................................... 10 5.1 FACILITIES ................................................................................................................................ 10 5.2 EQUIPMENT...............................................................................................................................10 5.3 TABLE OF ACCREDITATIONS AND LISTINGS.............................................................................. 11 6. SETUP OF EQUIPMENT UNDER TEST ...................................................................................................12 6.1 SETUP CONFIGURATION OF EUT................................................................................................ 12 6.2 SUPPORT EQUIPMENT ........................................................................................................ 12 7. FCC PART 15.249 REQUIREMENTS ........................................................................................................ 13 7.1 20 DB BANDWIDTH.............................................................................................................. 13 7.2 SPURIOUS EMISSION .......................................................................................................... 15 7.3 POWERLINE CONDUCTED EMISSIONS ........................................................................... 21 APPENDIX I PHOTOGRAPHS OF TEST SETUP ............................................................................................24 APPENDIX 1 - PHOTOGRAPHS OF EUT Compliance Certification Services Inc. FCC ID: SW8TD1030 Report No.: T110804213-RP1 Page 4 1. TEST RESULT CERTIFICATION Applicant: GOOD WAY TECHNOLOGY CO., LTD. 3F, No. 135, Ln. 235, Baociao Rd., Sindian Dist., New Taipei City 231, Taiwan, R.O.C. Equipment Under Test: Power Monitor Tr a d e N a m e : GOOD WAY Model Number: TD1030Z1 Date of Test: August 8 ~ 15, 2011 APPLICABLE STANDARDS STANDARD TEST RESULT FCC 47 CFR Part 15 Subpart C No non-compliance noted We hereby certify that: The above equipment was tested by Compliance Certification Services Inc. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4: 2003 and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements emission limits of FCC Rules Part 15.107, 15.109,15.207, 15.209 and 15.249. The test results of this report relate only to the tested sample identified in this report. Approved by: Reviewed by: Rex Lai Gina Lo Section Manager Section Manager Compliance Certification Services Inc. Compliance Certification Services Inc. Compliance Certification Services Inc. FCC ID: SW8TD1030 Report No.: T110804213-RP1 Page 5 2. EUT DESCRIPTION Product Power Monitor Trade Name GOOD WAY Model Number TD1030Z1 Model Discrepancy N/A Received Date August 4, 2011 Power Supply AC110~120V/60Hz Frequency Range 908 MHz Modulation Technique FSK Antenna Gain 2.13 dBi Antenna Designation PCB Antenna Remark: 1. The sample selected for test was production product and was provided by manufacturer. 2. This submittal(s) (test report) is i…
Text truncated - open the document above for the full version.
Compliance Certification Services Inc. FCC ID: SW8TD1030 Report No.: T110804213-RP1 Page 24 APPENDIX I PHOTOGRAPHS OF TEST SETUP Conducted Emission Set Up Photo Compliance Certification Services Inc. FCC ID: SW8TD1030 Report No.: T110804213-RP1 Page 25 Radiated Emission Set up Photos Compliance Certification Services Inc. FCC ID: SW8TD1030 Report No.: T110804213-RP1 Page 26 Powerline Conducted Emissions Setup Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 908.4 MHz - 908.4 MHz | - |
Human Presence Sensor
Equipment Class
DTS - Digital Transmission System
Wi-Fi & BLE M.2 Wireless Module
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Scene Button
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
802.11b/g/n and Z-WAVE
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
HP Wireless Streaming Connector
Equipment Class
DTS - Digital Transmission System