Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Mar 20, 2011
Application Purpose
Original Equipment
Date of Application
Mar 20, 2011
Equipment Note
Microprocessor Controlled Networked Locks
Frequency Range
0.12500000 - 0.12500000
Company
ASSA ABLOY Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: U4A-SCYPROX3 IC: 6982A-SCYPROX3 FCC Rule Part: 15.209 IC Radio Standards Specification: RSS-210 ACS Report Number: 10-0443.W06.11.A Manufacturer: Assa Abloy Model: S1-PA/PK, S2-PA/PK, TCIP1-M802/M803, TCWI1-M802/M803 Manual(s) Installation Instructions For ML20800 TCWI1 Series Mortise Lockset Important:The accuracy of the door preparation is critical for proper functioning and security of this lock. Misalignment can cause premature wear and a lessening of security. Please read these instructions carefully to prevent missing important steps. Please Note:Improper installation may result in damage to the lock and void the factory warranty. FM 335 (Rev. 01/2011) For installation assistance contact Corbin Russwin Inc., at 1-800-810-WIRE (9473) CAUTION DOOR MUST REMAIN OPEN DURING INSTALLATION. USE DOOR STOP. 123 4 7 5 8 0 6 9 # * TEST FOR PROPER OPERATION BEFORE CLOSING DOOR Access 800 TM 1) Warning 1 2) General Description/Specifications/Features 2 3) ML20800 TCAC2 Series Product Illustration 3 4) Installation Instructions 4-10 5) Installation of RF Technology Lock 11 6) Operational Check 12 Table of Contents This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced TV technician for help This Class B digital apparatus complies with Canadian ICES-003. Warning: To comply with “Fire Listed” doors, only alkaline batteries must be used. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 1) Warning 1 7.1) Important 13 7.2) Installation Notes 13 7.3) Electrolynx™ Connector System 13 7.4) ML20800 TCAC2 Series Illustration with M861 Harness 14 7.5) M861 Forced Door Propped Door Option 15 7.6) M35 Power/Remote Unlocking 16 7) ML20800 TCAC2 Hard Wiring Instructions for Mortise 13 7.7) M35 Power/Remote Unlocking with M861 Forced Door Propped Door Option 17 2 General Description The Corbin Russwin Access 800 TCWI1 Mortise Lock is designed for applications requiring wireless access control. The TCWI1 is a self-contained microprocessor-controlled access control product with non-volatile memory. It is able to utilize the existing wireless LAN 802.11 b/g in order to communicate with the access control system. The TCWI1 lock will hold a total of 2000 different user codes. This product is operated by six (6) "AA" alkaline batteries or by Corbin Russwin 784 9VDC power supply. Corbin Russwin Mortise locks are designed with quality components to provide high security, performance and durability. Specifications • Latch - Stainless Steel • Locking side controlled by any combination of keypad, prox card or cylinder override • Non-locking side lever retracts latch and • Deadbolt - Stainless Steel deadbolt • Auxiliary Latch - Stainless Steel, non handed • Handing - Easily field reversible without disassembling the lock body • Locks furnished for 1-3/4" doors. Can be • Case - 12 gauge heavy duty wrought steel furnished for other door sizes upon request. • UL Listed (3 hr.) (Consult Factory) Features • WiFi 802.11 b/g enabled • 2000 Users per lock (more possible with software) • 10,000 Event audit trail • Centralized lock management • Real Time Door Status Monitoring (Only applies when unit is hard powered) • Easy Installation • HID Prox Compatible (125kHz 26-39 Bit) 2) General Descriptions/ Specifications/ Features 3 3) ML20800 Series Product Illustration Verify Hand and Bevel of door. Illustrations shown are as viewed from the outside or secure side of opening. 1 4) Installation Instructions 3 2 4 Prep door according to supplied Corbin Russwin Inc. door marker. F O R U S E O N F I R E D O O R N O T Left Hand Hinges Left. Open Inward. "LH" Left Hand Reverse Bevel Hinges Left. Open Outward "LHR" Right Hand Hinges Right. Open Inward. "RH" Right Hand Reverse Bevel Hinges Right. Open Outward "RHR" 7/8" 1-1/2 1/8" Dia. holes (2) required Fire Stop Plate required for fire rated doors Slot Attach Fire Stop Plate Using self tapping screws #8-32x1/2 long for wood & metal doors .C of 1-1/2 Dia L Outside of Door Hole for ribbon cable Non Fire Rated Exterior Doors install weather conduit. (Hollow Doors Only) Outside of Door Non Fire Rated Door Hole for ribbon cable Install conduit half with recessed panel "Not For Use On Fire Door" visible from outside of door. The Optional Conduit is available for Non Fire rated doors to provide weather protection for exterior door applications. It is included in the M99 Weatherseal Gasketing Kit when ordered with the device. If ordered separately, order part number 794F929. Lock Assembly Instructions Align bevel accordingly. Engage 7/64 …

Text truncated - open the document above for the full version.

Users Manual

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: U4A-SCYPROX3 IC: 6982A-SCYPROX3 FCC Rule Part: 15.209 IC Radio Standards Specification: RSS-210 ACS Report Number: 10-0443.W06.11.A Manufacturer: Assa Abloy Model: S1-PA/PK, S2-PA/PK, TCIP1-M802/M803, TCWI1-M802/M803 Manual(s) A7764B 01/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. Profile PoE Mortise Lock Installation Instructions v.S1 1-800-810-WIRE • www.sargentlock.com • A7764B Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 01/29/11 1 2 3 4 5 6 7 Table of Contents Warning ...................................................................................2 General Description .................................................................3 Hardware Specifications .........................................................3 Electronic Specifications .........................................................3 Installation Wiring Overview ...................................................3 Installation Wiring ...................................................................4 Parts Breakdown .....................................................................8 Lock Installation ....................................................................10 Operational Check ................................................................17 8 9 Changes or modifications to this unit not expressly approved by ASSA ABLOY Inc. could void the user’s authority to operate the equipment. 1 Warning Warning SARGENT Mfg. Co. v.S Series locksets utilizing a door position switch (DPS) are not rated for, or intended for use in life safety applications. ! FCC: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equip- ment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio com- munications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Industry Canada: The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Op- eration is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe A répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. 01/29/11 1-800-810-WIRE • www.sargentlock.com • A7764B 3 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.S1 PoE Mortise Lock General Description The SARGENT Profile Series v.S1 Mortise Lock is available with either an HID® 125 kHz prox or 13.56 MHz iCLASS® technology reader. It utilizes existing infrastructure and IEEE 802.3af PoE (Power over Ethernet) technology as a proven alternative to traditional access control installations.The v.S1 is a self-contained microprocessor-controlled access control product with non-volatile memory. It uses the existing network cable to communicate with access control systems. The v.S1 lock holds a total of 2400 unique users per lock. Using PoE technology coupled with approved third party software, this v.S1 online lock offers a complete, integrated access control system. The Profile Series v.S1 Mortise lock may be used for both indoor and exterior applications. A weather-protective gasket is recommended for exterior applications. HID and iCLASS are registered trademarks of HID Global Corporation. Hardware Specifications 3 Electronic Specifications 4 2 Installation Wiring Overview 5 • 2400 users per lock; 10,000 event audit trail • Multiple time zone and holiday access scheduling • Centralized lock management • Real time door status monitoring • First-In unlock configuration, either by time or by user (selectable) • Lock down capable • Input Power: PoE Class 2 Device, as defined by IEEE 802.3af • Supports HID® 125 kHz prox or 13.56 MHz iCLASS® credentials (26 - 39 bit); supports CSN reads for other common 13.56 MHz cards, including MiFare, DesFire, and Felica • Complete lockset with on-board memory • Available with or without keypad • ADA compliant • Latch: One-piece stainless steel, 3⁄4"projection • Deadbolt: One-piece hardened stainless steel • Guardbolt: Stainless steel, non-handed • Case - 12 gauge, heavy duty, wrought steel • Inside lever retracts latch and deadbolt • UL Listed (3 hr.) • Handing (RH/LH/RHR/LHR) can be specified but is easily field-reversible without disassembling the lock body • Locks furnished for 1-3/4” doors. Can be fur- nished for other door sizes upon request. Con- sult factory. • Wire from EAC Panel to door must be shielded with drain terminated at EAC Panel …

Text truncated - open the document above for the full version.

Users Manual

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: U4A-SCYPROX3 IC: 6982A-SCYPROX3 FCC Rule Part: 15.209 IC Radio Standards Specification: RSS-210 ACS Report Number: 10-0443.W06.11.A Manufacturer: Assa Abloy Model: S1-PA/PK, S2-PA/PK, TCIP1-M802/M803, TCWI1-M802/M803 Manual(s) A7786E 01/11 Copyright 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. Profile WiFi Mortise Lock Installation Instructions v.S2 1-800-810-WIRE • www.sargentlock.com • A7786E Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 01/29/11 Warning: Changes or modifications to this unit not expressly approved by ASSA ABLOY Inc. could void the user’s authority to operate the equipment. Warning 1 1 2 3 4 5 6 7 Table of Contents Warning ...................................................................................2 General Description .................................................................3 Hardware Specifications .........................................................3 Electronic Specifications .........................................................3 Installation Wiring Overview ...................................................3 Lock Wiring ..............................................................................4 Parts Breakdown .....................................................................5 Installation Instructions ..........................................................7 Operational Check ................................................................15 8 9 To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only. SARGENT Mfg. Co. v.S Series locksets utilizing a door position switch (DPS) are not rated for, or intended for use in life safety applications. ! FCC: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Industry Canada: The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des- règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. 01/29/11 1-800-810-WIRE • www.sargentlock.com • A7786E 3 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.S2 WiFi Mortise Lock Hardware Specifications General Description The SARGENT Profile Series v.S2 mortise lock is available with either an HID® 125 kHz prox or 13.56 MHz iCLASS® technology reader. It is designed for applications requiring wireless access control. The v.S2 is a self-contained microprocessor-controlled access control product with non-volatile memory. It is able to utilize the existing wireless LAN (802.11b/g) in order to communicate with the access control system. The v.S2 lock holds a total of 2400 unique users per lock. This product is operated by six (6) “AA” alkaline batteries or a SARGENT 3267 9VDC power supply. SARGENT mortise locks are designed with quality components to provide high security, performance and durability. The Profile Series v.S2 mortise lock may be used for both indoor and exterior applications. A weather- protective gasket (provided with unit) is recommended for exterior applications. HID® and iCLASS® are registered trademarks of HID Global Corporation. • Wireless (WiFi 802.11 b/g) online, battery-operated • 2400 users per lock • 10,000 Event audit trail • Centralized lock management • Door Status Monitoring* • Easy installation (no need to hardwire) • Input Power: DC 9V, 1.5A (6 AA alkaline batteries or optional hard-powered) • Lockdown capable* • Supports HID® 125 kHz prox or 13.56 MHz iCLASS® credentials (26 - 39 bit); supports CSN reads for other common 13.56 MHz cards, including MiFare, Des- Fire, and Felica • Supports most current WiFi networks security standards • For specific security information, please contact a local ASSA ABLOY Door Se- curity Solutions sales consult…

Text truncated - open the document above for the full version.

Cover Letter(s)

Steven Pfalzgraf Applications Engineer Americas Division 110 Sargent Drive New Haven, CT 06511 USA Phone: +1 203 821-5714 Fax: +1 203 603-5981 Email: [email protected] January 20, 2011 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam: I hereby appoint Sam Wismer at Advanced Compliance Solutions, Inc. to act as our agent in the preparation of an application for equipment authorization of FCC ID: U4A-SCYPROX3 to the FCC Rules and Regulations. I certify that all exhibits contained within this filing properly describe the device or system for which authorization is sought. I further certify that appropriate arrangements have been made to assure that production units of this equipment bearing the name and FCC ID: U4A-SCYPROX3 listed in this application will continue to comply with the Commission's requirements. I further certify by signature below that no party (per 47 CFR 1.2002(b)) to the application is subject to a denial of Federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This appointment also includes the authority to complete FCC Form 731 on our behalf and sign the application as an authorized agent. Sincerely, Steven Pfalzgraf Applications Engineer

Cover Letter(s)

Advanced Compliance Solutions – 5015 B.U. Bowman Drive, Buford, GA 30518 Phone: (770) 831-8048 Fax: (770) 831-8598 February 24, 2011 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: Assa Abloy respectfully requests confidentiality of certain materials provided with the submission of the S1-PA/PK, S2-PA/PK, TCIP1-M802/M803, and TCWI1-M802/M803 under FCC ID: U4A-SCYPROX3 in accordance with FCC Regulations 0.459. The confidentiality request applies to the following exhibits: 10-0443 – Schematics.pdf 10-0443 – System Block Diagram.pdf 10-0443 – Theory of Operation.pdf The S1-PA/PK, S2-PA/PK, TCIP1-M802/M803, and TCWI1-M802/M803 have been developed at considerable effort and expense by Assa Abloy. These items are considered as Trade Secrets and therefore public access to the proprietary material could possibly result in duplication of equipment that could severely damage the company’s business advantage. I appreciate your assistance in this matter. Sincerely, Sam Wismer Vice President, Technology Agent

Cover Letter(s)

5015 B. U. Bowman Dr. Buford, GA 30518 February 23, 2011 ACS TCB 5015 B.U. Bowman Drive Buford, GA 30518 Re: FCC ID: U4A-SCYPROX3 To Whom It May Concern: The following application is submitted on behalf of our client, Assa Abloy, for evaluation of their models S1- PA/PK, S2-PA/PK, TCIP1-M802/M803, and TCWI1-M802/M803 for certification under FCC Part 15.209. The models listed above are electrically identical with respect to the 125kHz proximity reader and differ only in the options as described in this filing. The S1-PA/PK, S2-PA/PK, TCIP1-M802/M803, and TCWI1- M802/M803 were tested in full to the requirements of the aforementioned rules and were found to be in compliance. Sincerely, Sam Wismer Vice President, Technology Advanced Compliance Solutions, Inc.

External Photos

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: U4A-SCYPROX3 IC: 6982A-SCYPROX3 FCC Rule Part: 15.209 IC Radio Standards Specification: RSS-210 ACS Report Number: 10-0443.W06.11.A Manufacturer: Assa Abloy Model: S1-PA/PK, S2- PA/PK, TCIP1-M802/M803, TCWI1-M802/M803 External Photos FCC ID:U4A-SCYPROX3 IC:6982A-SCYPROX3 Models: S1-PA/PK, S2-PA/PK, TCWI1-M802/M803, and TCIP1-M802/M803 ACS Report: 10-0443.W06.11.A Advanced Compliance Solutions Page 2 Figure 1: Front View - Sargent Figure 2: Back View - Sargent FCC ID:U4A-SCYPROX3 IC:6982A-SCYPROX3 Models: S1-PA/PK, S2-PA/PK, TCWI1-M802/M803, and TCIP1-M802/M803 ACS Report: 10-0443.W06.11.A Advanced Compliance Solutions Page 3 Figure 3: Side View – Sargent Figure 4: Front View – Corbin-Russwin FCC ID:U4A-SCYPROX3 IC:6982A-SCYPROX3 Models: S1-PA/PK, S2-PA/PK, TCWI1-M802/M803, and TCIP1-M802/M803 ACS Report: 10-0443.W06.11.A Advanced Compliance Solutions Page 4 Figure 5: Back View – Corbin-Russwin Figure 6: Side View – Corbin-Russwin

ID Label/Location Info

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: U4A-SCYPROX3 IC: 6982A-SCYPROX3 FCC Rule Part: 15.209 IC Radio Standards Specification: RSS-210 ACS Report Number: 10-0443.W06.11.A Manufacturer: Assa Abloy Model: S1-PA/PK, S2- PA/PK, TCIP1-M802/M803, TCWI1-M802/M803 Label Information 11/04/2010 1 S1-PA/PK and TCIP1-M802/M803 (FCC Model/ID/IC and Pa rt 15 labels) – Lock Escutcheon S1-PA/PK and TCIP1-M802/M803 FCC Part 15 Label S1-PA/PK and TCIP1-M802/M803 FCC Model/ID/IC Label 11/04/2010 2 S1-PA/PK and TCIP1-M802/M803 (FCC Model/ID/IC and Part 15 labels) – Lock Escutcheon S1-PA/PK and TCIP1-M802/M803 FCC Model/ID/IC Labels 11/04/2010 3 S1-PA/PK and TCIP1-M802/M803 (FCC Model/ID/IC and Part 15 labels) – Lock Escutcheon S1-PA/PK and TCIP1-M802/M803 FCC Part 15 Label 11/04/2010 4 S2-PA/PK and TCWI1-M802/M803 (FCC Model/ID/IC and P art 15 labels) – Lock Escutcheon S2-PA/PK and TCWI1-M802/M803 FCC Part 15 Label S2-PA/PK and TCWI1-M802/M803 FCC Model/ID/IC Label 11/04/2010 5 S2-PA/PK and TCWI1-M802/M803 (FCC Model/ID/IC and P art 15 labels) – Lock Escutcheon S2-PA/PK and TCWI1-M802/M803 FCC Model/ID/IC Labels 11/04/2010 6 S2-PA/PK and TCWI1-M802/M803 (FCC Model/ID/IC and P art 15 labels) – Lock Escutcheon S2-PA/PK and TCWI1-M802/M803 FCC Part 15 Label

Internal Photos

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: U4A-SCYPROX3 IC: 6982A-SCYPROX3 FCC Rule Part: 15.209 IC Radio Standards Specification: RSS-210 ACS Report Number: 10-0443.W06.11.A Manufacturer: Assa Abloy Model: S1-PA/PK, S2-PA/PK, TCIP1-M802/M803, TCWI1-M802/M803 Internal Photos FCC ID:U4A-SCYPROX3 IC:6982A-SCYPROX3 Models: S1-PA/PK, S2-PA/PK, TCWI1-M802/M803, and TCIP1-M802/M803 ACS Report: 10-0443.W06.11.A Advanced Compliance Solutions Page 2 Figure 1: Ethernet PCB Figure 2: Ethernet PCB FCC ID:U4A-SCYPROX3 IC:6982A-SCYPROX3 Models: S1-PA/PK, S2-PA/PK, TCWI1-M802/M803, and TCIP1-M802/M803 ACS Report: 10-0443.W06.11.A Advanced Compliance Solutions Page 3 Figure 3: Ethernet PCB Figure 4: Controller PCB (Including Wifi Option) FCC ID:U4A-SCYPROX3 IC:6982A-SCYPROX3 Models: S1-PA/PK, S2-PA/PK, TCWI1-M802/M803, and TCIP1-M802/M803 ACS Report: 10-0443.W06.11.A Advanced Compliance Solutions Page 4 Figure 5: Controller PCB (Including Wifi Option) Figure 6: Controller PCB FCC ID:U4A-SCYPROX3 IC:6982A-SCYPROX3 Models: S1-PA/PK, S2-PA/PK, TCWI1-M802/M803, and TCIP1-M802/M803 ACS Report: 10-0443.W06.11.A Advanced Compliance Solutions Page 5 Figure 7: Keypad / Antenna Assembly Figure 8: Keypad / Antenna Assembly FCC ID:U4A-SCYPROX3 IC:6982A-SCYPROX3 Models: S1-PA/PK, S2-PA/PK, TCWI1-M802/M803, and TCIP1-M802/M803 ACS Report: 10-0443.W06.11.A Advanced Compliance Solutions Page 6 Figure 9: Coil Antenna Figure 10: Keypad

Test Report

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Test Report FCC ID: U4A-SCYPROX3 IC: 6982A-SCYPROX3 FCC Rule Part: 15.209 IC Radio Standards Specification: RSS-210 ACS Report Number: 10-0443.W06.11.A Manufacturer: Assa Abloy Model: S1-PA/PK, S2-PA/PK, TCIP1-M802/M803, TCWI1-M802/M803 Test Begin Date: December 21, 2010 Test End Date: December 29, 2010 Report Issue Date: February 24. 2011 FOR THE SCOPE OF ACCREDITATION UNDER LAB Code 200612-0 This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Reviewed by: Kirby Munroe Director, Wireless Certifications ACS, Inc. This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this report are representative of the sample(s) submitted for evaluation. This report contains 17 pages 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 TABLE OF CONTENTS 1 GENERAL ............................................................................................................................................ 3 1.1 PURPOSE .......................................................................................................................................... 3 1.2 PRODUCT DESCRIPTION ................................................................................................................... 3 1.3 TEST METHODOLOGY AND CONSIDERATIONS ................................................................................. 4 2 TEST FACILITIES .............................................................................................................................. 4 2.1 LOCATION ....................................................................................................................................... 4 2.2 LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS ................................................ 4 2.3 RADIATED EMISSIONS TEST SITE DESCRIPTION .............................................................................. 5 2.3.1 Semi-Anechoic Chamber Test Site .......................................................................................... 5 2.3.2 Open Area Tests Site (OATS) ................................................................................................. 6 2.4 CONDUCTED EMISSIONS TEST SITE DESCRIPTION ........................................................................... 7 3 APPLICABLE STANDARD REFERENCES .................................................................................... 7 4 LIST OF TEST EQUIPMENT ............................................................................................................ 8 5 SUPPORT EQUIPMENT .................................................................................................................... 9 6 SUMMARY OF TESTS ..................................................................................................................... 11 6.1 ANTENNA REQUIREMENT – FCC: SECTION 15.203 ....................................................................... 11 6.2 POWER LINE CONDUCTED EMISSIONS – FCC: SECTION 15.207 IC: RSS-GEN 7.2.2 ...................... 11 6.2.1 Measurement Procedure ....................................................................................................... 11 6.2.2 Measurement Results ............................................................................................................ 11 6.3 RADIATED EMISSIONS – FCC CFR 47 PART 15.209 / RSS-210 SECTION 2.6................................. 13 6.3.1 Measurement Procedure ....................................................................................................... 13 6.3.2 Distance Correction for Measurements Below 30 MHz – Part 15.31 .................................. 13 6.3.3 Measurement Results ............................................................................................................ 14 6.3.4 Sample Calculation ............................................................................................................... 15 6.4 20DB / 99% BANDWIDTH – FCC: SECTION 15.215(C) / IC: RSS-210 SECTION 4.6.1 ..................... 16 6.4.1 Measurement Procedure ....................................................................................................... 16 6.4.2 Measurement Results ............................................................................................................ 16 7 CONCLUSION ................................................................................................................................... 17 FCC ID:U4A-SCYPROX3 IC:6982A-SCYPROX3 Models: S1-PA/PK, S2-PA/PK, TCWI1-M802/M803, and TCIP1-M802/M803 ACS Report: 10-0443.W06.11.A Advanced Compliance Solutions Page 3 1 GENERAL 1.1 Purpose T…

Text truncated - open the document above for the full version.

Contact Information

Applicant

James Forte(Senior Product Compliance Engineer)
[email protected]2038215788Fax: 2034985600

Test Firm

Advanced Compliance Solutions, Inc.Randy Abernathy
[email protected]770-831-8048Fax: 770-831-8598

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from ASSA ABLOY Inc.

Real-Time Wireless Locks - FCC ID U4A-LNK100 - ASSA ABLOY Inc.
U4A-LNK100

Real-Time Wireless Locks

Sep 03, 2026

Equipment Class

DTS - Digital Transmission System
Wireless Interface Device - FCC ID U4A-ADA1028W2 - ASSA ABLOY Inc.
U4A-ADA1028W2

Wireless Interface Device

Aug 07, 2026

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Wireless Interface Device - FCC ID U4A5800ADAEZ2 - ASSA ABLOY Inc.
U4A5800ADAEZ2

Wireless Interface Device

Feb 20, 2026

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Aperio V3 IN100 Keypad Variant RF Module - FCC ID U4A-SCYMCA1K - ASSA ABLOY Inc.
U4A-SCYMCA1K

Aperio V3 IN100 Keypad Variant RF Module

Jul 28, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Access Control Lock - FCC ID U4A-CEX100 - ASSA ABLOY Inc.
U4A-CEX100

Access Control Lock

Jun 05, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter