FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SynapSense Corporation/
  3. U62-0883

U62-0883Wireless Damper Controller

SynapSense Corporation
Wireless Damper Controller - FCC ID U62-0883 - SynapSense Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 24, 2012
Application Purpose
Original Equipment
Date of Application
Jul 16, 2012
Equipment Note
Wireless Damper Controller
Frequency Range
2405.00000000 - 2480.00000000
Company
SynapSense Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

340 Palladio Parkway  Suite 540  Folsom  CA  95630 Wireless Damper Controller Installation and User Manual Document Number 85-0883-001 Author Lisa Brown Revision 1.0 Date April 20, 2012 SynapSense Installation and User Manual Release 1 Page 2 Table of Contents Regulatory Notices ............................................................................................................ 3 1 Operation .................................................................................................................... 5 2 Wireless Damper Controller Installation Requirements ....................................... 6 2.1 Mounting ......................................................................................................................................................................6 2.2 Connections ...............................................................................................................................................................7 3 Troubleshooting and Diagnostics ........................................................................... 8 SynapSense Installation and User Manual Release 1 Page 3 Regulatory Notices Notice to Users: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user’s expense. FCC Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Antenna Statement: Only the antenna supplied with this unit may be used. Any attempt to modify this antenna or substitute a different antenna by any means shall void the warranty and will void the FCC approval to operate this equipment CE Statement: This equipment has been tested and found to comply with the limits of the European Council Directive on the approximation of the law of the member states relating to electromagnetic compatibility (89/336/EEC) according to EN 55022 Class B. Industry Canada Equipment Notice: The Industry Canada certification identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Document(s). The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure, for their own protection, that the electrical ground connectors of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This presentation may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority or electrician, as appropriate. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. SynapSense Installation and User Manual Release 1 Page 4 Warranty Information Limited One Year Warranty Our company warrants that for two years from the date of purchase, it will replace this product if found to be defective in materials or workmanship. For a prompt, no charge replacement of equivalent product, return the defective product postage prepaid to the appropriate address. Product Support Center 340 Palladio Parkway, Suite 540 Folsom, CA 95630 United States of America This replacement is the company's sole obligation under this warranty. SynapSense, Inc. will not be responsible for any incidental or consequential damages or for any loss arising in connection with the use or inability to use this product. Some states/provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty excludes defects or damage due to …

Text truncated - open the document above for the full version.

ID Label/Location Info

Regulatory Label, DAMPER CONTROL NODE SIZEFSCM NODWG NOREV A 60-0952-0012 SCALE 1:2 SHEET 1 of 1 2.0 1.5 Dimensions in inches Model: 0883 FCC ID: U62-0883, IC: 7265A-0883 4 Part Number: 99-0883-001 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 1. Material: See BOM for Blank Label 2. Text: Arial or equivalent, size per best fit 3. After printing, verify text does not smear/rub 4. Apply SynapSense and other Logo’s per files provided 5. Serial Number and Human Readable Barcode: See Notes Below 6. Mark Applicable Part Number Revision Serial Number (Human Readable): PR = Fixed character (Pride); (AM for Amperor) YY = Year (2010 = 10) WW = Work Week (assigned per manufacturer calendar) ZZZZ = Sequentially assigned number (hex-decimal 0-F) DA = DA (Product Code for Damper Control) Barcode: Code 128, 0.1" Tall min., verify barcode is scannable Barcode matches human readable characters PRYYWWZZZZDA 5 6 0.2"

RF Exposure Info

The output power of this product is below the threshold requiring RF exposure evaluation. This device is exempt from RF Exposure review.

Test Report

This report contains a total of 44 pages and may be reproduced in full only. Partial reproduction may only be done with the written consent of CKC Laboratories, Inc. SynapSense Corporation ADDENDUM TEST REPORT TO 92868-9A Wireless Damper Controller, 0883 Tested To The Following Standards: FCC Part 15 Subpart C Sections 15.207, 15.209, 15.247 and RSS 210 Issue 8 Report No.: 92868-9B Date of issue: July 25, 2012 This test report bears the accreditation symbol indicating that the testing performed herein meets the test and reporting requirements of ISO/IEC 17025 under the applicable scope of EMC testing for CKC Laboratories, Inc. We strive to create long-term, trust based relationships by providing sound, adaptive, customer first testing services. We embrace each of our customers’ unique EMC challenges, not as an interruption to set processes, but rather as the reason we are in business. Page 2 of 44 Report No.: 92868-9B TABLE OF CONTENTS Administrative Information .......................................................................................................................... 3 Test Report Information ............................................................................................................................................ 3 Revision History ......................................................................................................................................................... 3 Report Authorization ................................................................................................................................................. 3 Test Facility Information ............................................................................................................................................ 4 Site Registration & Accreditation Information .......................................................................................................... 4 Summary of Results ................................................................................................................................................... 5 Conditions During Testing.......................................................................................................................................... 5 Equipment Under Test ............................................................................................................................................... 6 Peripheral Devices ..................................................................................................................................................... 6 FCC Part 15 Subpart C ................................................................................................................................... 7 15.207 AC Conducted Emissions ................................................................................................................................ 7 15.209 Radiated Emissions ...................................................................................................................................... 15 15.247 RF Power Output ......................................................................................................................................... 21 -6dBc Occupied Bandwidth ..................................................................................................................................... 24 Bandedge ................................................................................................................................................................. 27 15.247(e) Power Spectral Density ........................................................................................................................... 30 15.247(d) Radiated Spurious Emissions ................................................................................................................... 34 RSS-210 ....................................................................................................................................................... 40 99 % Bandwidth ....................................................................................................................................................... 40 Supplemental Information .......................................................................................................................... 43 Measurement Uncertainty ...................................................................................................................................... 43 Emissions Test Details .............................................................................................................................................. 43 Page 3 of 44 Report No.: 92868-9B ADMINISTRATIVE INFORMATION Test Report Information REPORT PREPARED FOR: REPORT PREPARED BY: SynapSense Corporation 340 Palladio Parkway, Suite 540 Folsom, CA 95630 Joyce Walker CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 Representative: Michele Clemente Project Number: 92868 Customer Reference Number: 10440 DATE OF EQUIPMENT RECEIPT: May 9,2012 DATE(S) OF TESTING: May 9-30,2012 Revision History Original: Testing of the Wireless Damper Controller, 0883 to FCC Part 15 Subpart C Sections 15.207, 15.209, 15.247 and RSS-210 issue 8. Addendum A: To correct an error in the test condition in section 15.209 with regards to the height the EUT was above the ground plane, change the test conditions in 15.247(e) and replace the Bandedge section with revised information. Addendum B: To correct an error in the PSD test results. Report Authorization The test data contained in this report documents the observed testing parameters pertaining to and are relevant for only the sample equipment tested in the agreed upon operational mode(s) and configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This report may not be used to claim product endorsement by A2LA or any government agen…

Text truncated - open the document above for the full version.

Test Setup Photos

LOW MID HIGH

Contact Information

Applicant

Jeffery Fitch(Senior Product Manager)
[email protected]916-293-0916Fax: 916-294-0270

Technical Contact

SynapSense CorporationAbraham Fechter
[email protected]916-293-0930

340 Palladio Parkway, Suite 540 · Folsom, California · United States

Non-Technical Contact

SynapSense CorporationMichele Clemente
[email protected]916-467-1708

Test Firm

CKC Laboratories, Inc.Steve Behm
[email protected]209-966-5240Fax: 866-779-9776

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.60 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from SynapSense Corporation

Wireless Pressure Sensor - FCC ID U62-1532 - SynapSense Corporation
U62-1532

Wireless Pressure Sensor

Aug 20, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless subfloor differential pressure and temperature sensor node. - FCC ID U62-1259 - SynapSense Corporation
U62-1259

Wireless subfloor differential pressure and temperature sensor node.

Nov 02, 2015

Equipment Class

DTS - Digital Transmission System
802.15.4 Wireless Intelligent Gateway - FCC ID U62-1156 - SynapSense Corporation
U62-1156

802.15.4 Wireless Intelligent Gateway

Jan 12, 2014

Equipment Class

DTS - Digital Transmission System
Thermanode EZ - FCC ID U62-0944 - SynapSense Corporation
U62-0944

Thermanode EZ

Aug 19, 2012

Equipment Class

DTS - Digital Transmission System
SynapSense P3 SmartPlug Power Meter in data center server cabinets - FCC ID U62-SJA100 - SynapSense Corporation
U62-SJA100

SynapSense P3 SmartPlug Power Meter in data center server cabinets

Aug 24, 2011

Equipment Class

DTS - Digital Transmission System