FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SynapSense Corporation/
  3. U62-1259

U62-1259Wireless subfloor differential pressure and temperature sensor node.

SynapSense Corporation
Wireless subfloor differential pressure and temperature sensor node. - FCC ID U62-1259 - SynapSense Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 02, 2015
Application Purpose
Original Equipment
Date of Application
Oct 22, 2015
Equipment Note
Wireless subfloor differential pressure and temperature sensor node.
Frequency Range
2405.00000000 - 2480.00000000
Company
SynapSense Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Subfloor EZ Node Hardware Installation Guide Version 1.0 Subfloor EZ Node Hardware Installation Guide Version 1.0 ii SynapSense Subfloor EZ Node Hardware Installation Guide © 2006 – 2015 SynapSense Corporation. All Rights Reserved This documentation is protected by United States and international copyright and other intellectual and industrial property laws. It is solely owned by SynapSense Corporation and its licensors and is distributed under a restrictive license. This product, or any portion thereof, may not be used, copied, modified, reverse assembled, reverse compiled, reverse engineered, distributed, or redistributed in any form by any means without the prior written authorization of SynapSense Corporation. RESTRICTED RIGHTS: Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227-14(g) (2)(6/87) and FAR 52.227-19(6/87), or DFAR 252.227-7015 (b)(6/95) and DFAR 227.7202-3(a), and any and all similar and successor legislation and regulation. SynapSense Corporation 340 Palladio Parkway, Suite 530 Folsom, CA 95630 Tel: (916) 294-0110 Fax: (916) 294-0270 Web: www.SynapSense.com Subfloor EZ Node Hardware Installation Guide Version 1.0 iii Trademarks SynapSense®, the SynapSense logo and SynapSoft™ are registered trademarks or trademarks of SynapSense Corporation. All third-party brand and product names are the trademarks of their respective owners and are used solely for informational purposes. Disclaimer This documentation is provided “as is” without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or fitness for a particular purpose. This documentation might include technical inaccuracies or other errors. Corrections and improvements might be incorporated in new versions of the documentation. SynapSense does not assume any liability arising out of the application or use of any products or services and specifically disclaims any and all liability, including without limitation consequential or incidental damages. SynapSense products are not designed for use in life support appliances, devices, or other systems where malfunction can reasonably be expected to result in significant personal injury to the user, or as a critical component in any life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. SynapSense customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify and hold SynapSense and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SynapSense was negligent regarding the design or manufacture of its products. SynapSense reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products or services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to SynapSense Corporation's terms and conditions of sale supplied at the time of order acknowledgment or sale. SynapSense does not warrant or represent that any license, either express or implied, is granted under any SynapSense patent right, copyright, mask work right, or other SynapSense intellectual property right relating to any combination, machine, or process in which SynapSense products or services are used. Information published by SynapSense regarding third-party products or services does not constitute a license from SynapSense to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from SynapSense under the patents or other intellectual property of SynapSense. Regulatory Information Notice to Users: This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and the receiver.  Plug the equipment into an outlet on a circuit different from that which the receiver is plugged.  Consult the dealer or an experienced radio/TC technician for help. This product works using a radio frequency, so use on an airplane may be restricted due to interference. Subfloor EZ Node Hardware Installation Guide Version 1.0 iv FCC Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The antenna(s) used for this transm…

Text truncated - open the document above for the full version.

Cover Letter(s)

3 4 0 P a l l a d i o P a r k w a y , S u i t e 530  F o l s o m , C A U S A 9 5 6 3 0  T : + 1-916-294-0 1 1 0  F : + 1-916-294-0270 09/11/2015 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Permanent Confidentiality To whom it may concern: In accordance with 47CFR Section 0.457 and Section 0.459 pertaining to confidential material, we hereby request to hold permanently confidential all information contained within the below identified exhibits/document categories submitted pursuant to radio equipment certification requirements for FCC ID: U62-1259. 1. All Block Diagrams 2. Operational Description 3. All Schematics 4. Parts List (BOM) The above material contains trade secrets and proprietary information as specified by 47CFR 0.457(d) and technical data, which would customarily be guarded from competitors. The public disclosure of this information might be harmful to our company and provide unjustified benefits to our competitors. Sincerely, Abraham Fechter Senior Electronics Engineer Panduit

RF Exposure Info

RADIO FREQUENCY EXPOSURE REPORT FOR THE Device: Subfloor EZ Model: 1259 Report No.: 96902-25A Date of issue: October 21, 2015 PREPARED FOR: SynapSense a Panduit Company 340 Palladio Pkwy, Suite 530 Folsom CA 95630 PREPARED BY: Chuck Kendall CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 The test data contained in this report documents the observed testing parameters pertaining to and are relevant for only the sample equipment tested in the agreed upon operational mode(s) and configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This report may not be used to claim product endorsement by A2LA or any government agencies. This test report has been authorized for release under quality control from CKC Laboratories, Inc. Steve Behm Director of Quality Assurance & Engineering Services CKC Laboratories, Inc. Page 2 of 11 Report No: Insert report number Purpose: To demonstrate compliance with United States, Canada, Australia and/or European Union RF Exposure requirements for Portable equipment (devices used ≤20cm from the body) or Mobile equipment (devices used >20cm from the body) with power output below exemption levels and Mobile equipment, where Maximum Permissible Exposure (MPE) Calculations apply. Device and Antenna Operating Configuration: Device operating at maximum output power with continuous transmission of modulated data 2405 MHz through 2480 MHz. Test Procedure: This equipment is evaluated in accordance with the guidelines set forth in OET Guide 65 & ANSI C95.1 for the US, Health Canada Safety Code 6 & RSS 102 for Canada and EN 62479 or EN 62311 for EU. Other Considerations: Report considers stand-alone configurations only. Simultaneous transmissions are not evaluated. RF Exposure limits are calculated at the low-point of the operating band -2400-2483.5 MHz. Referenced Test Reports: The following test reports were referenced in conjunction with this assessment: 96902-11A and 96902-15A Page 3 of 11 Report No: 96902-25A RF Exposure Exemption Calculations US Exemption Power Reported is: ☒ Peak ☐ Average Limit Used is: ☒ General Population ☐ Occupational Exposure Operating Band MHz Power dBm Ant Type/Gain dBi EIRP dBm Distance cm Exemption Limit Comments 2400-2483.5 -3.729 3.3 -0.429 0.5 Limit Ratio = 3.0 Exempt Calculated RF Exposure Ratio = 0.3 (in accordance with KDB 447498) IC Exemption Power Reported is: ☒ Peak ☐ Average Limit Used is: ☒ General Population ☐ Occupational Exposure Operating Band MHz Power dBm Ant Type/Gain dBi EIRP dBm Distance m Exemption Limit Comments 2400-2483.5 -3.729 3.3 -0.429 0.005 6 dBm Exempt AU Exemption Power Reported is: ☒ Peak ☐ Average Limit Used is: ☒ General Population ☐ Occupational Exposure Operating Band MHz Power dBm Ant Type/Gain dBi EIRP dBm Distance m Exemption Limit Comments 2400-2483.5 -3.729 3.3 -0.429 -- 13 dBm Exempt EU Exemption Power Reported is: ☒ Peak ☐ Average Limit Used is: ☒ General Population ☐ Occupational Exposure Operating Band MHz Power dBm Ant Type/Gain dBi EIRP dBm Distance m Exemption Limit Comments 2400-2483.5 -3.729 3.3 -0.429 -- 13 dBm Exempt Page 4 of 11 Report No: 96902-25A Summary: Exemptions: Equipment demonstrating compliance by portable RF exposure exemption have been evaluated, without further testing, for use under either portable or mobile RF exposure configurations. Additional configurations including collocation or simultaneous transmission with other transmitters (including necessary separation distances) are subject to further assessment. Certain exemption criteria may define specific separation distances. It is assumed that the manufacturer shall design the equipment such that these minimum separation distance is met. MPE Calculation Results: Equipment demonstrating compliance with MPE calculations have been evaluated, without further testing, for use under mobile RF exposure configurations as identified herein. Additional configurations including collocation or simultaneous transmission with other transmitters (including necessary separation distances) are subject to further assessment. It is assumed that the manufacturer shall design the equipment such that the minimum separation distance of 20cm (or greater, as listed above) is met or that the manufacturer provides a protection guide (e.g. installation instructions) to the end user such that the antenna(s) may be installed in accordance with the manufacturer’s instructions in such a manor to maintain the minimum separation distance. General Comments: The absorption and distribution of Electromagnetic energy in the body is a very complex phenomena that depends on the mass, shape and physiological condition of the body; the orientation of the body with respect to the fields; and, the electrical properties of the body and the environment. Variables that may play a substantial role in possible biological effects are those that characterize the environment (including but not limited to: ambient temperature, air velocity, relative humidity and body insulation); and those that characterize the individual (including but not limited to: age, gender, activity level and existing debilitation or disease). Because innumerable factors may interact to determine specific biological effects of exposure to electromagnetic fields, any protection guide should consider both intended and unintended operational environments and provide guidance for installation and use of the product such that proper separation distances can be maintained. (ANSI C95.1) Page 5 of 11 Report No: 96902-25A APPENDIX A - RF Exposure Limits United States Compliance Requirements (1.1310): RF Exposure Evaluation Limits Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3-3.0 614 1.63 *(100) 6 3.0-30 1842/f 4.89/f *(900/f 2 ) 6 30-300 61.4 0.163 1 6 300-1500 --- --- f/300 6 1500-100,000 --- --- 5.0 6 RF Exposure Evaluation L…

Text truncated - open the document above for the full version.

Test Report

This report contains a total of 26 pages and may be reproduced in full only. Partial reproduction may only be done with the written consent of CKC Laboratories, Inc. SynapSense a Panduit Company EMC TEST REPORT FOR Subfloor EZ Model: 1259 Tested To The Following Standards: FCC Part 15 Subpart C Section 15.247 Report No.: 96902-11 Date of issue: August 3, 2015 This test report bears the accreditation symbol indicating that the testing performed herein meets the test and reporting requirements of ISO/IEC 17025 under the applicable scope of EMC testing for CKC Laboratories, Inc. We strive to create long-term, trust based relationships by providing sound, adaptive, customer first testing services. We embrace each of our customers’ unique EMC challenges, not as an interruption to set processes, but rather as the reason we are in business. Page 2 of 26 Report No.: 96902-11 TABLE OF CONTENTS Administrative Information .......................................................................................................................... 3 Test Report Information ............................................................................................................................................ 3 Report Authorization ................................................................................................................................................. 3 Test Facility Information ............................................................................................................................................ 4 Software Versions ...................................................................................................................................................... 4 Site Registration & Accreditation Information .......................................................................................................... 4 Summary of Results ................................................................................................................................................... 5 Modifications During Testing ..................................................................................................................................... 5 Conditions During Testing.......................................................................................................................................... 5 Equipment Under Test ............................................................................................................................................... 6 FCC Part 15 Subpart C ................................................................................................................................... 7 15.247(a)(2) -6dB Occupied Bandwidth .................................................................................................................... 7 15.247(b)(3) Maximum Power Output .................................................................................................................... 10 15.247(d) Field Strength of Radiated Spurious Emissions and Band Edge .............................................................. 15 15. 247(e) Power Spectral Density .......................................................................................................................... 21 Supplemental Information .......................................................................................................................... 25 Emissions Test Details .............................................................................................................................................. 25 Page 3 of 26 Report No.: 96902-11 ADMINISTRATIVE INFORMATION Test Report Information REPORT PREPARED FOR: REPORT PREPARED BY: SynapSense a Panduit Company 340 Palladio Pkwy, Suite 530 Folsom, CA 95630 Morgan Tramontin CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 Representative: Abraham Fechter Project Number: 96902 Customer Reference Number: 452570 DATE OF EQUIPMENT RECEIPT: May 27, 2015 DATE(S) OF TESTING: June 1-4 & July 17, 2015 Report Authorization The test data contained in this report documents the observed testing parameters pertaining to and are relevant for only the sample equipment tested in the agreed upon operational mode(s) and configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This report may not be used to claim product endorsement by A2LA or any government agencies. This test report has been authorized for release under quality control from CKC Laboratories, Inc. Steve Behm Director of Quality Assurance & Engineering Services CKC Laboratories, Inc. Page 4 of 26 Report No.: 96902-11 Test Facility Information Our laboratories are configured to effectively test a wide variety of product types. CKC utilizes first class test equipment, anechoic chambers, data acquisition and information services to create accurate, repeatable and affordable test results. TEST LOCATION(S): CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 Software Versions CKC Laboratories Proprietary Software Version EMITest Emissions 5.02.00 EMITest Immunity 5.02.00 Site Registration & Accreditation Information Location CB # TAIWAN CANADA FCC JAPAN Mariposa A US0103 SL2-IN-E-1147R 3082A-2 90477 A-0136 Page 5 of 26 Report No.: 96902-11 SUMMARY OF RESULTS Standard / Specification: FCC Part 15 Subpart C Test Procedure Description Modifications* Results 15.247(a)(2) Occupied Bandwidth NA Pass 15.247(b)(3) Maximum Power Output NA Pass 15.247(d) Field Strength of Radiated Spurious Emissions and Band Edge NA Pass 15.247(e) Power Spectral Density NA Pass Modifications* During Testing This list is a summary of the modifications made to the equipment during testing. Summary of Conditions No modifications were made during testing. *Modifications listed above must be incorporated into all production units. Conditions During Testing This list is a summary of the conditions noted t…

Text truncated - open the document above for the full version.

Test Setup Photos

X-Axis Y-Axis Z-Axis

Contact Information

Applicant

Jeffery Fitch(Senior Product Manager)
[email protected]916-293-0916Fax: 916-294-0270

Technical Contact

SynapSense CorporationAbraham Fechter
[email protected]916-293-0930

340 Palladio Pkwy · Folsom, California · United States

Test Firm

CKC Laboratories, Inc.Steve Behm
[email protected]209-966-5240Fax: 866 779 9776

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz424.00 µW
Confidentiality
Long Term
Grant Notes
Power listed in conducted.

Other Applications from SynapSense Corporation

Wireless Pressure Sensor - FCC ID U62-1532 - SynapSense Corporation
U62-1532

Wireless Pressure Sensor

Aug 20, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
802.15.4 Wireless Intelligent Gateway - FCC ID U62-1156 - SynapSense Corporation
U62-1156

802.15.4 Wireless Intelligent Gateway

Jan 12, 2014

Equipment Class

DTS - Digital Transmission System
Thermanode EZ - FCC ID U62-0944 - SynapSense Corporation
U62-0944

Thermanode EZ

Aug 19, 2012

Equipment Class

DTS - Digital Transmission System
Wireless Damper Controller - FCC ID U62-0883 - SynapSense Corporation
U62-0883

Wireless Damper Controller

Jul 24, 2012

Equipment Class

DTS - Digital Transmission System
SynapSense P3 SmartPlug Power Meter in data center server cabinets - FCC ID U62-SJA100 - SynapSense Corporation
U62-SJA100

SynapSense P3 SmartPlug Power Meter in data center server cabinets

Aug 24, 2011

Equipment Class

DTS - Digital Transmission System