Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SynapSense™ P 3 SmartPlug Power Meter User Guide Aug. 5, 2011 SynapSense™ P 3 SmartPlug Power Meter User Guide 2 Revision 1.0 Copyright © 2010 SynapSense™ Corporation [Page Left Blank] SynapSense™ P 3 SmartPlug Power Meter User Guide Copyright © 2010 SynapSense™ Corporation Revision 1.0 3 Contents Contents ................................................................................................................................................ 3 Figures ................................................................................................................................................... 4 Warnings and Precautions ................................................................................................................. 9 Introduction ........................................................................................................................................ 10 Overview ......................................................................................................................................... 10 Software Requirements ..................................................................................................................... 11 Power Meter and Electrical Specifications ..................................................................................... 11 P3 SmartPlug Power Meter Measurement Range: ................................................................ 11 P3 SmartPlug Maximum Electrical Ratings: .......................................................................... 11 Controller: ................................................................................................................................... 11 Maintenance and Calibration ................................................................................................... 11 Regulatory Information .................................................................................................................... 12 SmartPlug Radio (Viking Radio): ............................................................................................ 12 Controller Radio’s (WSN and Viking Radio’s): ..................................................................... 12 Power Meter: .............................................................................................................................. 12 Environmental Conditions ............................................................................................................... 12 P3 SmartPlug: ............................................................................................................................. 12 Controller: ................................................................................................................................... 12 Controller Power Adapter: ....................................................................................................... 12 Part Number and Model Information ............................................................................................ 13 P3 SmartPlug PowerMeter Part Number Explanation: ....................................................... 13 P3 SmartPlug PowerMeter Model Number Explanation: ................................................... 13 Installation .......................................................................................................................................... 14 Technical Support .............................................................................................................................. 15 SynapSense™ P 3 SmartPlug Power Meter User Guide 4 Revision 1.0 Copyright © 2010 SynapSense™ Corporation Figures Figure 1 – P 3 SmartPlug Power Meter ............................................................................................. 10 Figure 2 – P 3 SmartPlugs installed in a server cabinet .................................................................. 14 SynapSense™ P 3 SmartPlug Power Meter User Guide Copyright © 2010 SynapSense™ Corporation Revision 1.0 5 SynapSense Corporation 2365 Iron Point Road, #100 Folsom, CA 95630 Tel: (916) 294-‐‑0110 Fax: (916) 294-‐‑0270 www.SynapSense.com Status: Released Revision: 1.0 Release Date: August 5, 2011 Changes From Previous Revision: Add Part Number Explanation Page (Rev 0.2) Add model number in explanation page (Rev 0.3) Add French language to regulatory (Rev 0.4) Corrected headers and released (Rev 1.0) SynapSense™ P 3 SmartPlug Power Meter User Guide 6 Revision 1.0 Copyright © 2010 SynapSense™ Corporation Trademarks SynapSense™, the SynapSense™ logo and SynapSoft™ are trademarks of SynapSense™ Corporation. All third-‐‑ party brand and product names are the trademarks of their respective owners and are used solely for informational purposes. Copyright This documentation is protected by United States and international copyright and other intellectual and industrial property laws. It is solely owned by SynapSense™ Corporation and its licensors and is distributed under a restrictive license. This product, or any portion thereof, may not be used, copied, modified, reverse assembled, reverse compiled, reverse engineered, distributed, or redistributed in any form by any means without the prior written authorization of SynapSense™ Corporation. RESTRICTED RIGHTS: Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227-‐‑14(g) (2)(6/87) and FAR 52.227-‐‑19(6/87), or DFAR 252.227-‐‑7015 (b)(6/95) and DFAR 227.7202-‐‑3(a), and any and all similar and successor legislation and regulation. Disclaimer This documentation is provided “as is” without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or fitness for a particular purpose. This documentation might include technical inaccuracies or other errors. Corrections and improvements might be incorporated in new versions of the documentation. SynapSense™ does not a…
Text truncated - open the document above for the full version.
2365 Iron Point Rd Suite 100 Folsom CA 95630 SynapSense Corporation 2365 Iron Point Rd., Suite 100 Folsom, CA 95630 916-293-0934 FCC Confidential Authorization December 3, 2010 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: U62-SJA100 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, SynapSense Corporation hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Pat Weston VP Engineering SynapSense Corporation
2365 Iron Point Rd, Suite 100 Folsom, CA USA 95630 T:+1-916-294-0110 F: +1-916-294-0270 December 3, 2010 To Whom It May Concern: We the undersigned hereby delegate power of attorney to CKC Certification Services, LLC (CKC CS) to act on our behalf in matters of radio equipment certification. CKC CS is appointed as an agent to sign applications before regulatory agency(ies) on our behalf, and to receive and exchange data between our company and the agency(ies). Sincerely, Pat Weston VP Engineering SynapSense Corporation 2365 Iron Point Road, Suite 100 Folsom, CA 95630 916-293-0934
Regulatory Label, JAWA SIZE FSCM NO DWG NO REV A 60-0642-001 G SCALE 2:1 SHEET 1 of 1 1. Material: See BOM for Blank Label2. Text: Arial Narrow or equivalent, size per best fit 3. After printing, verify text does not smear/rub4. SynapSense Logo (no TM)5. SynapSense Part#, Length, Model#, and Max Curre nt: Part Number: 99-0642 corresponds to Model 0642, 10amps max, 18/3AWG cord, Length overall in i nches Part Number: 99-0643 corresponds to Model 0643, 15amps max, 14/3AWG cord, Length overall in i nches 6. Current Hardware and Software Revision7. Serial Number Human Readable and Barcode: See content instructions 2.165 1.22 Dimensions in inches Serial Number (Human Readable): AM = Fixed characters (Amperor) YY = Year (2010 = 10)WW = Work Week (assigned per manufacturer calendar)ZZZZZ = Sequentially assigned number (decimal 0-9)CC = Checksum Barcode Number: AMYYWWZZZZZCC converted to 32bit number per Manufacturing Test Software.Barcode Type: Code 128, 0.1" Tall min., verify barcode is scannableNOTE: This label is generated by the Validation Test Software. AMYYWWZZZZZCC 7 4 Part# 99-0642-0150-0150 (15")Model: 0642FCC ID: U62-SJA100 / IC: 7265A-SJA100Input/Output: 100 – 240VAC, 50/60HzMax Current: 10ampsF/W: 1.0.0 H/W: X73 Made in China 5 6
The output power of this product is below the threshold requiring RF exposure evaluation. This device is exempt from RF Exposure review.
This report c written cons e TE S CERT #803 803.05 ontains a total of ent of CKC Laborat STING 3.01, 803.02, 5, 803.06 47 pages and ma tories, Inc. Syna Te FCC Part 15 This test rep testing perfo of ISO/IEC 1 CKC Laborato We strive t o sound, adapt our custome processes, bu ay be reproduced apSens TEST Plug M ested To The Subpart C S RSS Repor Date of issu port bears th ormed herein 17025 under ories, Inc. o create long‐t tive, customer ers’ unique EM ut rather as th in full only. Partia se Corp REPORT FO Meter, 064 e Following S Sections 15.2 and 210 Issue 8 rt No.: 91167 ue: February 3 e accreditatio meets the tes the applicab term, trust ba r first testing MC challenges, e reason we a al reproduction m poratio OR 42 Standards: 207, 15.209, 8 ‐9 3, 2011 on symbol ind st and reporti ble scope of sed relations h services. We , not as an int are in business may only be done on , 15.247 dicating that ing requireme EMC testing hips by provid embrace each terruption to . with the the ents for ding h of set Page 2of 47 Report No.: 91167‐9 TABLE OF CONTENTS Administrative Information ........................................................................................................................................... 3 Test Report Information ............................................................................................................................................ 3 Report Authorization ................................................................................................................................................. 3 Test Facility Information ............................................................................................................................................ 4 Site Registration & Accreditation Information .......................................................................................................... 4 Summary of Results ................................................................................................................................................... 5 Conditions During Testing ......................................................................................................................................... 5 Equipment Under Test ............................................................................................................................................... 6 Peripheral Devices ..................................................................................................................................................... 6 FCC Part 15 Subpart C .................................................................................................................................................... 7 15.207 AC Conducted Emissions................................................................................................................................ 7 15.209/15.247(d) Spurious Radiated Emissions ...................................................................................................... 16 15.47(b)(3) RF Power Output .................................................................................................................................. 33 15.247(a)(2) Occupied Bandwidth ........................................................................................................................... 35 15.247(e) Power Spectral Density ........................................................................................................................... 38 15.247(d) Bandedge ................................................................................................................................................ 40 RSS‐210 ........................................................................................................................................................................ 43 99% Bandwidth ........................................................................................................................................................ 43 Supplemental Information ............................................................................................................................... ........... 46 Measurement Uncertainty ...................................................................................................................................... 46 Emissions Test Details .............................................................................................................................................. 46 Page 3of 47 Report No.: 91167‐9 ADMINISTRATIVE INFORMATION Test Report Information REPORT PREPARED FOR: REPORT PREPARED BY: SynapSense Corporation 2365 Iron Point Road, Suite 100 Folsom, CA 95630 Dianne Dudley CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 Representative: Pat Weston Project Number: 91167 Customer Reference Number: 9948 DATE OF EQUIPMENT RECEIPT: October 20, 2010 DATE(S) OF TESTING: October 20, 2010 –January 29, 2011 Report Authorization The test data contained in this report documents the observed testing parameters pertaining to and are relevant for only the sample equipment tested in the agreed upon operational mode(s) and configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This report may not be used to claim product endorsement by A2LA or any government agencies. This test report has been authorized for release under quality control from CKC Laboratories, Inc. Steve Behm Director of Quality Assurance & Engineering Services CKC Laboratories, Inc. Page 4of 47 Report No.: 91167‐9 Test Facility Information Our laboratories are configured to effectively test a wide variety of product types. CKC utilizes first class test equipment, anechoic chambers, data acquisition and information services to create accurate, repeatable and affordable test results. TEST LOCATION(S): CKC Laboratories, Inc. 1120 Fulton Place Fremont, CA 94539 Site Registration & A…
Text truncated - open the document above for the full version.
9kHz ‐ 30MHz Mag Loop Antenna 30‐1000MHz Bi Log Antenna 1‐18GHz Horn Antenna 18‐26.5GHz Horn Antenna
2365 Iron Point Road, Suite 100 · Folsom, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.47 GHz | 260.00 µW |

Wireless Pressure Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless subfloor differential pressure and temperature sensor node.
Equipment Class
DTS - Digital Transmission System
802.15.4 Wireless Intelligent Gateway
Equipment Class
DTS - Digital Transmission System
Thermanode EZ
Equipment Class
DTS - Digital Transmission System
Wireless Damper Controller
Equipment Class
DTS - Digital Transmission System