FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN TENDA TECHNOLOGY CO., LTD./
  3. V7TA33V2

V7TA33V2AX3000 Dual-Band Gigabit Wi-Fi Range Extender, AX1800 Dual-Band Gigabit Wi-Fi Range Extender

SHENZHEN TENDA TECHNOLOGY CO., LTD.
AX3000 Dual-Band Gigabit Wi-Fi Range Extender, AX1800 Dual-Band Gigabit Wi-Fi Range Extender - FCC ID V7TA33V2 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 25, 2026
Application Purpose
Original Equipment
Equipment Note
AX3000 Dual-Band Gigabit Wi-Fi Range Extender, AX1800 Dual-Band Gigabit Wi-Fi Range Extender
Frequency Range
2412.00000000 - 2462.00000000
Company
SHENZHEN TENDA TECHNOLOGY CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

4 Wireless Extension Upstream Wi-Fi Name Tenda_XXXXXX Upstream Wi-Fi Password Please enter Cancel Next Wi-Fi Wi-Fi Tenda_EXT Connected 1 Start Now Thanks for Choosing Tenda WiFi Range Extender Faster, Safer, Smoother, Smarter 2 • Ensure that the router has a WPS button and is using WPA2-PSK, WPA/WPA2-PSK, or WPA3-SAE/ WPA2-PSK encryption. • The WPS design may differ with different manufacturers. If this method fails, use another method to configure. • The extender can form a Mesh network with Tenda Wi-Fi+ Mesh or EasyMesh-compatible routers. Method 1: Via Smartphone Web Browser (Recommended) 2. Set Up the Extender Method 2: Via Tenda WiFi App Method 3: Via WPS Button Within 2 minutes Wireless Extension Your working mode has been detected as: Wireless Extension Select the Wi-Fi to be extended Recommended to select 5GHz Wi-Fi Switch Tenda_XXXXXX 5G/2.4G 3 Connect your phone to the extender's default Wi-Fi: Tenda_EXT *If The WLAN is not connected to the Internet appears, select Use Without Internet to continue. *Ignore Unsecured Network prompt. The welcome page appears automatically. If not, disable cellular data and visit re.tenda.cn in your browser. 1 Connect the extender's Ethernet port to a wall Ethernet jack (with internet access) using an Ethernet cable. When the indicator turns from blinking green to solid green, the connection is established. 3 Start Now Thanks for Choosing Tenda WiFi Range Extender Faster, Safer, Smoother, Smarter 4 Wired Extension Set Wi-Fi password to the management password Extender 2.4 GHz Wi-Fi Name Tenda_EXT Extender 5 GHz Wi-Fi Name Tenda_5G_EXT Extender Wi-Fi Password Please enter Previous Next Unify 2.4 GHz & 5 GHz Your working mode has been detected as: Wired Extension Switch 2 Wi-Fi Wi-Fi Tenda_EXT Connected Set the Wi-Fi name, Wi-Fi password and management password of the extender. Tap Next. Internet WAN/LAN POWER 1 2 3 4 WPS/ RESET Connect your phone to the extender's default Wi-Fi: Tenda_EXT *If The WLAN is not connected to the Internet appears, select Use Without Internet to continue. *Ignore Unsecured Network prompt. *If you don’t see Tenda_EXT, the extender may already be connected in a Mesh network. In this case, it uses the same Wi-Fi name and password as your router. The welcome page appears automatically. If not, disable cellular data and visit re.tenda.cn in your browser. Tips Dual-band extension is supported: If the main router provides dual-band Wi-Fi, you can select either band to extend (5 GHz is recommended). The extender will automatically use the same Wi-Fi password to extend the other band. Tips Select the router's Wi-Fi to extend.Enter the Wi-Fi password of the router, and tap Next. Set the Wi-Fi name, Wi-Fi password and management password of the extender as required. If nothing changes, tap Next. When the indicator is solid on, the setup is successful. A: Upstream router without Mesh support - Extender Wi-Fi name: Upstream router Wi-Fi name_EXT (or _5G_EXT), same as the upstream router (only for 5 GHz Wi-Fi) - Extender Wi-Fi password: Same as the upstream router B: Upstream router with Mesh support - Extender Wi-Fi name/password: Same as the upstream router 2 Within 2 minutes, press the WPS button on the extender for about 1 to 3 seconds, and its indicator blinks green fast. 1 Or Download Tenda WiFi app, then register and log in. 234 Wireless Extension... Working Mode Select the Wi-Fi to be extended Recommended to select 5 GHz Wi-Fi Tenda_XXXXXX 5G/2.4G Wi-Fi Wi-Fi Tenda_EXT Connected Connect your phone to the extender's default Wi-Fi: Tenda_EXT *If The WLAN is not connected to the Internet appears, select Use Without Internet to continue. *Ignore Unsecured Network prompt. Select the Wi-Fi to extend, then follow the setup wizard to configure the extender (refer to steps ~ in Method 1). *Bind the extender to enable remote management. Not Now Configure Signal Extender is found unconfigured. Configure it now? Connect Extender to the Internet Wired clients (Connected only via wireless extension. For wired extension, connect via Wi-Fi.) Wireless clients (such as a smartphone) Printer Smart TV Camera Computer WAN/LAN POWER 1 2 3 4 WPS/ RESET 5 *Extender network settings. If nothing changes, tap Next. Extender 2.4 GHz Wi-Fi Name Tenda_XXXXXX_EXT Add New Wi-Fi Use upstream Wi-Fi name/password Set Wi-Fi password to the management password Broadcasts the same 5 GHz Wi-Fi name and password as the upstream router for smoother roaming. Extender 5 GHz Wi-Fi Name Tenda_XXXXXX_5G_EXT Extender Wi-Fi Password • • • • • • • • 5GHz Enhanced Roaming Tenda_XXXXXX Wireless Extension Previous Next ➌ ➎ WPS/RESET Recommended: Place the extender midway between the router and the Wi-Fi dead zone. *Ensure your phone can connect to the router's 5 GHz Wi-Fi and access the internet. WPS/RESET WPS/RESET A solid LED indicates successful extension. If the indicator is yellow or red, move the extender closer to the router until it turns solid green. Using 5 GHz Wi-Fi is recommended. *If the indicator remains solid yellow when placed near the router, see FAQ > Q8. 1. Select the extender location Place the extender midway between the router and the Wi-Fi dead zone to ensure stable signal reception and effective area coverage. Wireless Extension Ensure Ethernet cables are installed in areas where Wi-Fi coverage is needed and internet access is available. For in-wall wiring, use the included Ethernet cable. Wired Extension Ethernet cable WPS/RESET WAN/LAN POWER 1 2 3 4 WPS/ RESET WAN/LAN POWER 1 2 3 4 WPS/ RESET Product Introduction The extender supports both wireless and wired extension. If you have Ethernet cables deployed in your home, it is recommended to use the AP Mode. Otherwise, opt for the Wireless Extension. Choose the extension type as required, and refer to the following section for configuration. Wireless Extension The extender connects to the upstream router through Wi-Fi and extends the router's Wi-Fi coverage. The extender connects to the upstream router t…

Text truncated - open the document above for the full version.

Attestation Statements

SHENZHEN TENDA TECHNOLOGY CO., LTD. Add: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Tel: 86-755-27657098 Fax: 86-755-27657178 E-mail: [email protected] Attestation Letter Date: 2026-07-31 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam: Our product AX3000 Dual-Band Gigabit Wi-Fi Range Extender, Model: A33, AX1800 Dual-Band Gigabit Wi-Fi Range Extender, model: A23, FCC ID: V7TA33V2, for marketing purpose, this product only supports 2.4G Wi-Fi (2412-2462MHz, 802.11b/g/n20/ax20 modes, 2422-2452MHz, 802.11n40/ax40 modes), 5G Wi-Fi (5150-5250MHz; 5250-5350MHz; 5725-5850MHz, 802.11a/n20/ac20/ax20/n40/ac40/ax40/ac80/ax80/ac160/ax160 modes),802.11ax mode only supports full RU and doesn't support partial RU. The other functions, bands and modes was disabled to use by manufacturer in the software, the end user has no capability to activate it. Sincerely, Printed Name: Shen Yue Title: Engineer

Attestation Statements

CFR 47 §2.911(d)(5)(i)(ii) Attestation Letter SHENZHEN TENDA TECHNOLOGY CO., LTD. Add: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Tel: 86-755-27657098 Fax: 86-755-27657178 E-mail: [email protected] Attestation Letter Date: 2026-07-31 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i)(ii) Filing FCC ID: V7TA33V2 SHENZHEN TENDA TECHNOLOGY CO., LTD. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. SHENZHEN TENDA TECHNOLOGY CO., LTD. (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. SHENZHEN TENDA TECHNOLOGY CO., LTD. certifies that the equipment does not use Kaspersky's software information. Sincerely, Signature: Contact Person: Shen Yue Title: Engineer

Cover Letter(s)

QA-FR-170-B SHENZHEN TENDA TECHNOLOGY CO., LTD. Add: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Tel: 86-755-27657098 Fax: 86-755-27657178 E-mail: [email protected] FCC Authorization Date: 2026-07-31 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, SHENZHEN TENDA TECHNOLOGY CO., LTD., hereby authorizes China Certification ICT Co., Ltd (Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by China Certification ICT Co., Ltd (Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Client’s signature Printed Name: Shen Yue Title: Engineer

Cover Letter(s)

QA-FR-171-A SHENZHEN TENDA TECHNOLOGY CO., LTD. Add: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Tel: 86-755-27657098 Fax: 86-755-27657178 E-mail: [email protected] FCC Confidential Authorization Date: 2026-07-31 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID:V7TA33V2 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, SHENZHEN TENDA TECHNOLOGY CO., LTD. hereby requests long-term confidential treatment of information accompanying this application as outlined below: • Block Diagram • Schematics • Operation Description • U-NII Device Security Declaration The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Printed Name: Shen Yue Title: Engineer

Cover Letter(s)

SHENZHEN TENDA TECHNOLOGY CO., LTD. Add: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Tel: 86-755-27657098 Fax: 866-755-27657178 E-mail: [email protected] DECLARATION OF SIMILARITY Date: 2026-7- 31 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam: We, SHENZHEN TENDA TECHNOLOGY CO., LTD., hereby declare that the product: AX1800 Dual-Band Gigabit Wi-Fi Range Extender, FCC ID: V7TA33V2, model: A23 is electrically identical with the product: AX3000 Dual-Band Gigabit Wi-Fi Range Extender, model: A33 which was tested by China Certification ICT Co., Ltd (Dongguan). A description of the differences between those models and that are declared similar are as follows: They are just the different model name, product name for various distribution channels, the rest are the same. Please contact me should there be need for any additional clarification or information. Best Regards, Signature: Printed Name: Shen Yue Title: Engineer

External Photos

China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-EXP Page 1 / 8 EUT EXTERNAL PHOTOGRAPHS A33(Apply for FCC&ISEDC) China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-EXP Page 2 / 8 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-EXP Page 3 / 8 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-EXP Page 4 / 8 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-EXP Page 5 / 8 A23(Only apply for FCC) China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-EXP Page 6 / 8 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-EXP Page 7 / 8 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-EXP Page 8 / 8 *****END *****

ID Label/Location Info

Shen zhen Tenda Technology Co., Ltd. 6-8 Floor, Tower E3, No.1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 www.tendacn.com Made in China MAC: XXXXXXXXXXXX SSI D: Tenda_EXT XXXXXXXXXXXXXXXXX VX.X S/N: A X1800 Dual-Band Gigabit Wi-Fi Range Extender Model: A23 Default Access: re.tenda.cn Power: 100-240V~ 50/60Hz 0.4A FCC ID: V7TA33V2

ID Label/Location Info

Shenzhen Tenda Technology Co., Ltd. 6-8 Floor, Tower E3, No.1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 www.tendacn.com Made in China MAC: XXXXXXXXXXXX SSID: Tenda_EXT XXXXXXXXXXXXXXXXX VX.X S/N: AX3000 Dual-Band Gigabit Wi-Fi Range Extender Model: A33 Default Access: re.tenda.cn Power: 100-240V~ 50/60Hz 0.4A FCC ID: V7TA33V2 HVIN:A33V2 CANICES-003(B)/NMB-003(B) IC:9034A-A33V2

Internal Photos

China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page1/ 15 EUT INTERNAL PHOTOGRAPHS Model: A33 Wifi Antenna (Chain 1) Wifi Antenna (Chain 0) China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page2/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page3/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page4/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page5/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page6/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page7/ 15 Wifi Antenna(Chain 1) Wifi Antenna(Chain 0) China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page8/ 15 Model: A23 Wifi Antenna (Chain 1) Wifi Antenna (Chain 0) China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page9/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page10/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page11/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page12/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page13/ 15 China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page14/ 15 Wifi Antenna(Chain 1) China Certification ICT Co., Ltd (Dongguan) EXHIBIT No.: 2603U28676E-RF-INP Page15/ 15 Wifi Antenna(Chain 0) *****END *****

RF Exposure Info

RF EXPOSURE EVALUATION REPORT Applicant: SHENZHEN TENDA TECHNOLOGY CO.,LTD. Address: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 FCC ID: V7TA33V2 Product Name: AX3000 Dual-Band Gigabit Wi-Fi Range Extender AX1800 Dual-Band Gigabit Wi-Fi Range Extender Standard(s): 47 CFR §1.1307, 47 CFR §2.1091, 47 CFR §15.247(i), 47 CFR §15.407(f) The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: 2603U28676E-RF-00D Date Of Issue: 2026/8/17 Reviewed By: Calvin Chen Title: RF Test Supervisor Reviewed By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) Room 101 & 201, Building 2, 256 Pingdong Road, Dalang Town, Dongguan City, Guangdong, China. Tel: +86-769-83085888 www.ccttt.com.cn China Certification ICT Co., Ltd (Dongguan) Report No.: 2603U28676E-RF-00D Report Template: RF-FCC MPE-A/0 Page 2 of 6 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the Room 101 & 201, Building 2, 256 Pingdong Road, Dalang Town, Dongguan City, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. Each test item follows the test standard(s) without deviation. China Certification ICT Co., Ltd (Dongguan) Report No.: 2603U28676E-RF-00D Report Template: RF-FCC MPE-A/0 Page 3 of 6 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 4 1. GENERAL INFORMATION .................................................................................................... 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 5 2. RF EXPOSURE EVALUATION .............................................................................................. 6 2.1 RF EXPOSURE EVALUATION ............................................................................................................... 6 2.1.1 Applicable Standard ....................................................................................................................................... 6 2.1.2 Calculation formula: ...................................................................................................................................... 6 2.1.3 Calculated Data: ............................................................................................................................................. 6 China Certification ICT Co., Ltd (Dongguan) Report No.: 2603U28676E-RF-00D Report Template: RF-FCC MPE-A/0 Page 4 of 6 DOCUMENT REVISION HISTORY Revision Number Report Number Description of Revision Date of Revision 1.0 2603U28676E-RF-00D Original Report 2026/8/17 China Certification ICT Co., Ltd (Dongguan) Report No.: 2603U28676E-RF-00D Report Template: RF-FCC MPE-A/0 Page 5 of 6 1. GENERAL INFORMATION 1.1 Product Description for Equipment under Test (EUT) EUT Name: AX3000 Dual-Band Gigabit Wi-Fi Range Extender AX1800 Dual-Band Gigabit Wi-Fi Range Extender EUT Model: A33 Multiple Model: A23 Rated Input Voltage: AC 120V EUT Received Date: 2026/6/17 EUT Received Status: Good Note: The multiple models are electrically identical with the test model. Please refer to the declaration letter for more detail, which was provided by manufacturer. China Certification ICT Co., Ltd (Dongguan) Report No.: 2603U28676E-RF-00D Report Template: RF-FCC MPE-A/0 Page 6 of 6 2. RF EXPOSURE EVALUATION 2.1 RF Exposure Evaluation 2.1.1 Applicable Standard According to subpart 15.247(i), 15.407(f) and subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. 2.1.2 Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4R² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); 2.1.3 Calculated Data: Operation Modes Frequency (MHz) Ant…

Text truncated - open the document above for the full version.

Test Report

SHENZHEN TENDA TECHNOLOGY CO.,LTD. Measurement of Antenna for A33 Project Manufacture:SHENZHEN TENDA TECHNOLOGY CO.,LTD. 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Model: A33 Antenna 1. Antenna Appearance: Antenna1 Antenna2 2. Electrical performance test results at normal temperature SHENZHEN TENDA TECHNOLOGY CO.,LTD. a) Antenna1 No Test Item Unit Demand Performance Test Result Judgement 1 Frequency Range MHz 2400-2500/5150-5850 2400-2500/5150-5850 OK 2 Gain dBi / 2410 2.18 OK 2450 2.35 OK 2480 2.20 OK 5150 4.46 OK 5500 4.31 OK 5850 4.83 OK 3 Return loss dB ≤-10 2410 -14 OK 2450 -14 OK 2480 -13 OK 5150 -14 OK 5500 -15 OK 5850 -13 OK SHENZHEN TENDA TECHNOLOGY CO.,LTD. Directional diagram Frequency Gain (dBi) Efficiency 2400MHz 2.32 79% 2410MHz 2.18 78% 2420MHz 2.14 78% 2430MHz 2.24 80% 2440MHz 2.34 79% 2450MHz 2.35 82% 2460MHz 2.36 76% 2470MHz 2.34 80% 2480MHz 2.20 80% 2490MHz 2.27 76% 2500MHz 2.38 77% 2.4GHz 3D Radiation patterns H PLANE V PLANE 2.4GHz 2D Radiation patterns (2410MHz) Frequency Gain (dBi) Efficiency( ) 5150MHz 4.46 71% 5200MHz 4.38 72% 5250MHz 4.37 73% 5300MHz 4.47 74% 5350MHz 4.44 72% 5400MHz 4.54 72% 5450MHz 4.38 73% 5500MHz 4.31 71% 5550MHz 4.11 71% 5600MHz 4.57 70% 5650MHz 4.25 71% SHENZHEN TENDA TECHNOLOGY CO.,LTD. 5700MHz 4.28 72% 5750MHz 4.41 70% 5800MHz 4.55 70% 5850MHz 4.83 69% 5GHz 3D Radiation patterns H PLANE V PLANE 5GHz 2D Radiation patterns (5150MHz) b) Antenna2 No Test Item Unit Demand Performance Test Result Judgement 1 Frequency Range MHz 2400-2500/5150-5850 2400-2500/5150-5850 OK 2 Gain dBi / 2410 3.38 OK 2450 3.56 OK 2480 3.23 OK 5150 4.11 OK 5500 4.44 OK 5850 4.65 OK 3 Return loss dB ≤-10 2410 -13 OK 2450 -12 OK 2480 -12 OK 5150 -12 OK 5500 -15 OK 5850 -14 OK SHENZHEN TENDA TECHNOLOGY CO.,LTD. Directional diagram Frequency Gain (dBi) Efficiency 2400MHz 3.33 76% 2410MHz 3.38 76% 2420MHz 3.42 76% 2430MHz 3.53 77% 2440MHz 3.56 79% 2450MHz 3.56 79% 2460MHz 3.55 80% 2470MHz 3.45 80% 2480MHz 3.23 80% 2490MHz 2.96 79% 2500MHz 2.85 80% 2.4GHz 3D Radiation patterns H PLANE V PLANE 2.4GHz 2D Radiation patterns (2410MHz) Frequency Gain (dBi) Efficiency( ) 5150MHz 4.11 73% 5200MHz 4.00 74% 5250MHz 4.59 74% 5300MHz 4.04 74% 5350MHz 4.73 71% 5400MHz 4.69 72% 5450MHz 4.50 75% 5500MHz 4.44 73% 5550MHz 4.42 73% 5600MHz 4.36 71% 5650MHz 4.47 69% 5700MHz 4.18 72% SHENZHEN TENDA TECHNOLOGY CO.,LTD. 5750MHz 5.11 69% 5800MHz 4.04 70% 5850MHz 4.65 69% 5GHz 3D Radiation patte H PLANE V PLANE 5GHz 2D Radiation patterns (5750MHz)

Test Report

TEST REPORT Applicant: SHENZHEN TENDA TECHNOLOGY CO.,LTD. Address: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 FCC ID: V7TA33V2 IC: 9034A-A33V2 HVIN: A33V2 Product Name: FCC: AX3000 Dual-Band Gigabit Wi-Fi Range Extender AX1800 Dual-Band Gigabit Wi-Fi Range Extender IC: AX3000 Dual-Band Gigabit Wi-Fi Range Extender Standard(s): 47 CFR Part 15, Subpart C(15.247) RSS-247 Issue 4, July 24, 2025 RSS-Gen, Issue 5, February 2021 Amendment 2 ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+Errata to C63.10a-2024 KDB 558074 D01 15.247 Meas Guidance v05r02 The above device has been tested and found compliant with the requirement of the relativestandards by China Certification ICT Co., Ltd (Dongguan) Report Number: 2603U28676E-RF-00A Date Of Issue: 2026/8/10 Reviewed By: Calvin Chen Title: RF Test Supervisor Approved By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) Room 101 & 201, Building 2, 256 Pingdong Road, Dalang Town, Dongguan City, Guangdong,China. Tel: +86-769-83085888 www.ccttt.com.cn China Certification ICT Co., Ltd (Dongguan) Report No.:2603U28676E-RF-00A Report Template: RF-FCC&ISED-2.4G WIFI-A/1 Page 2 of 114 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the Room 101 & 201, Building 2, 256 Pingdong Road, Dalang Town, Dongguan City, Guangdong,China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. Each test item follows the test standard(s) without deviation. China Certification ICT Co., Ltd (Dongguan) Report No.:2603U28676E-RF-00A Report Template: RF-FCC&ISED-2.4G WIFI-A/1 Page 3 of 114 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.1.1 General ........................................................................................................................................................... 6 1.1.2 Operation Frequency Detail ........................................................................................................................... 6 1.1.3 Antenna Information Detail▲ ....................................................................................................................... 7 1.1.4 Accessory Information ................................................................................................................................... 7 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 8 1.2.1 EUT Operation Condition: ............................................................................................................................. 8 1.2.2 Support Equipment List and Details .............................................................................................................. 8 1.2.3 Support CableList and Details ....................................................................................................................... 9 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 9 1.3 MEASUREMENT UNCERTAINTY ........................................................................................................ 11 2. SUMMARY OF TEST RESULTS .......................................................................................... 12 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 13 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 13 3.1.1 Applicable Standard ..................................................................................................................................... 13 3.1.2 EUT Setup.................................................................................................................................................... 15 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 15 3.1.4 Test Procedure ............................................................................................................................................. 16 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 16 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 17 3.2.1 Applicable Stan…

Text truncated - open the document above for the full version.

Test Report

China C  Test Inf Environ T Test Eq Manu An An R east J * Statem National Certification IC formation: Sample No.: Test Site: Tester: nmental Co Temperature: (°C) quipment Li ufacturer nritsu nritsu R&S tsheep JD ment of Trace l Primary Stan CT Co., Ltd (D 3OAN-3 RF Chin Qin onditions: 23.6-2 ist and Deta Descripti Power Me Pulse Power Spectrum An Coaxial Atte Test softw ability: China ndards and In Dongguan) 24.1 ails: ion eter Sensor nalyzer enuator ware a Certification nternational Sy Relative Hum Model ML2495 MA2411 FSU26 2W-SMA-JK JD Auto Test n ICT Co., Ltd System of Units midity: (%) l 5A 1A 6 K-18G System d (Dongguan) s (SI). Test Da Test Mo Test Resu 52-53 Serial Numb 1106009 10780 200256 21060301 V1.0 attests that al ate:2026/06 de:Transmi ult:Pass AT er Calibra 202 202 202 Eac N ll calibrations Report No.:2 6/24~2026/08/ itting TM Pressure: (kPa) ation Date 5/08/05 5/08/19 6/02/17 ch time N/A s have been pe 2603U28676E Pag /02 99.8- Calibration D 2026/08 2026/08 2027/02 N/A N/A erf…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shen Yue(Engineer)
[email protected]Fax: 86-755-27657178

Technical Contact

Tenda Technology,IncSunny Chang
[email protected]

530 Technology Drive suite100 · Irvine, California, 92618 · United States

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Ora Huang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz216.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes.

Other Applications from SHENZHEN TENDA TECHNOLOGY CO., LTD.

AX1800 Wi-Fi 6 Dual-Band USB Adapter - FCC ID V7TU18V3 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TU18V3

AX1800 Wi-Fi 6 Dual-Band USB Adapter

Aug 26, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
6MP Dual-lens Linkage Wi-Fi Pan/Tilt Camera - FCC ID V7TCH9V2 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCH9V2

6MP Dual-lens Linkage Wi-Fi Pan/Tilt Camera

Jul 20, 2026

Equipment Class

DTS - Digital Transmission System
3MP Wi-Fi Pan/Tilt Camera - FCC ID V7TCH3V21 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCH3V21

3MP Wi-Fi Pan/Tilt Camera

Jul 14, 2026

Equipment Class

DTS - Digital Transmission System
3MP Security Pan/Tilt Camera - FCC ID V7TCP3P1 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCP3P1

3MP Security Pan/Tilt Camera

Jun 30, 2026

Equipment Class

DTS - Digital Transmission System
3MP Security Pan/Tilt Camera - FCC ID V7TCP3V32 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCP3V32

3MP Security Pan/Tilt Camera

Jun 29, 2026

Equipment Class

DTS - Digital Transmission System