FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN TENDA TECHNOLOGY CO., LTD./
  3. V7TMESH15XP

V7TMESH15XPAX5400 Whole Home Mesh Wi-Fi 6 System

SHENZHEN TENDA TECHNOLOGY CO., LTD.
AX5400 Whole Home Mesh Wi-Fi 6 System - FCC ID V7TMESH15XP - SHENZHEN TENDA TECHNOLOGY CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 04, 2023
Application Purpose
Original Equipment
Date of Application
Apr 02, 2023
Equipment Note
AX5400 Whole Home Mesh Wi-Fi 6 System
Frequency Range
2412.00000000 - 2462.00000000
Company
SHENZHEN TENDA TECHNOLOGY CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

SHENZHEN TENDA TECHNOLOGY CO.,LTD. Add: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Tel: 86-755-27657098Fax: 866-755-27657178 E- mail: [email protected] D ate: 2023-03-17 To : FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Declaration Subject: FCC ID:V7TMESH15XP declaration of frequency bands restriction Dear Si r or Madam: We, SHENZHEN TENDA TECHNOLOGY CO.,LTD., hereby declare that our product AX5400 Whole Home Mesh Wi-Fi System, Model Number: Mesh15XP,MX15 Pro,EX15 Pro,EM15 Pro have the ability to work in 2.4G and 5G 4 frequency bands: 5150 MHz~5250 MHz,5250 MHz~5350MHz,5470 MHz~5725 MHz, 5725 MHz~5850 MHz. For the purpose of marketing, the frequency of the product sold in U.S. are programmed and locked to work only in 5150 MHz~5250 MHz , 5250 MHz~5350MHz, 5725 MHz~5850 MHz, The other frequency bands5470 MHz~5725 MHz are disabled by firmware in factory. The end user or any other parties cannot have the capability to activate the other frequency bands. We applied for testing only frequency bands: 2412~2462 MHz (802.11b/g/n ht20/802.11n ht40/ax hew40/ax hew20),5150 MHz~5250 MHz, 5250MHz~5350MHz,5725 MHz~5850 MHz (802.11a/n ht20/ ac vh t20/ax hew20/802.11n ht4 0/ac vht40/ax hew40/802.11ac vht80/ax hew80/802.11ac vht160/ax hew160)for the United States this time . P lease contact me if you have any question. S ignature: Printed Name: Shen Yue Title: Engineer

Attestation Statements

       !"# $%# &## "#  '"(')( *  ' # ++, -+ +,-+-.#/-++,-+-- 0#')(1( #)   &2-3,.454+54'54''5 (("(#('  ((    677897:7;<=>8778?  #(,,-  &  @@AB B  @@ BB  %('*#(' # C#%#(' 'C'"'  -2+ #D# @'"&# %0E'#@,2  &F ((" (#(' (#(0 (" &2-3,.454+54'54''5'' !   BG -@+HI  JKLMNKL MOLMPQOLRKMSTSUVRSWXTOPW4Y(#ZZ')# ([5)('F'"(#((\%'Z0 (F ')#%( '*#(' '""%!(;9=<7Y)C[\%'Z0 (Z'E'(F0)'C' !#  \%'Z0 (#%('*#(' Z%"%# ((")(' ,.F( %"  JKLMNKL MOLMPQOLRKMSTSUVRSWXTOP4Y(#ZZ')# ([5)('F'"(#(#"F(#(F (F'' ! F(#ZZ')#(' (#ZZ')# ('" (' ('F' ( C '"(#"#  ('($ Z%)' ! Y)C[\%'Z0 (  ' )$      '! #(%   (#)(I "  % '( !'  0Z# $#0] ""     ]   !"# $%# &## "# '"(')( *  ' #++, 

Attestation Statements

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

Cover Letter(s)

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

Cover Letter(s)

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

Cover Letter(s)

       !"# $%# &## "#  '"(')( *  ' # ++, -++,- +-.#/-++,-+-- 0#')(1( #)  234567689:;:<=9>956798? @ABCDEFEGHFGHIJ  KL@LMNOPQRRSTUPNVUQTWPQRR UWWUQT NXBYZ[\]AB\Z^A^_L`AaXAB\Z^@\`\b\Z^ JcGdQAeaA^_R\aabMZA_ PZaXfg\AhR@EIFci  @CA[W\[Z[R A_AfD  jChWkLTlkLTVLT@NVLPkTQOQmnPQohOV@ohYC[Cgp_CqaA[CBYABBYCr[Z_XqBDNsdcFF jYZaCkZfC RCbYj\HK\WpbBCfhfZ_CaD  RsIdt[ZhLsIdt[Zh u\BYBYCfZ_ CaD  RCbYIdst uY\qYuAbBCbBC_gpPY\^APC[B\v\qAB\Z^ bAfCCaCqB[Zf Ax^CB\qCf\bb\Z^bA^_CaCqB[ZfAx^CB\qqZfrAB\g\a\Bp  N_Cbq[\rB\Z^ ZvBYC_\vvC[C^qCbgCBuCC^BYZbCfZ_CabA^_BYABA[C_CqaA[C_b\f\aA[A[CAbvZaaZubD VYCpA[CBYCb AfCr[Z_XqBhA^_zXbBBYC_\vvC[C^BfZ_Ca^AfCoBYC[CbBA[CBYCbAfCo VYC_CBA\a\^vZ[fAB\Z^hraCAbCqYCqeBYC[CrZ[Bbo  taCAbCqZ^BAqB fCbYZXa_BYC[CgC^CC_vZ[A^pA__\B\Z^AaqaA[\v\qAB\Z^Z[\^vZ[fAB\Z^o  {CbBMCxA[_bh   W\x^ABX[CD  |' (#0    % '( !'    i w@Z^xxXA^yu\BYBYC A[CCaCqB[\qAaap\_C^B\qAa LRIdt[Z    BG -@+HI h UPVPZohOB_ qYA[AqBC[\bB\qbo 

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS 2.4G Antenna Chain 0 5G Antenna 2.4GAntenna 2.4G Antenna Chain 1 5G Antenna Chain 0 5G Antenna Chain 1 5G Antenna Chain 2 5G Antenna Chain 3 5GHz Chain 3 5GHz Chain 2 5GHz Chain 1 5GHz Chain 0 2.4GHz Chain 1 2.4GHz Chain 0

RF Exposure Info

China Certification ICT Co., Ltd (Dongguan) Report No.: CR221261979-00A Page 85 of 86 5. RF EXPOSURE EVALUATION 5.1 Applicable Standard FCC §15.247 (i) Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. See §1.1307(b)(1) of this chapter. 5.2 Procedure According to §1.1307(b)(3)(i) (C) Or using Table 1 and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least λ/2π, where λ is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of λ/4 or if the antenna gain is less than that of a half-wave dipole (1.64 linear value). Table 1 to § 1.1307(b)(3)(i)(C) - Single RF Sources Subject to Routine Environmental Evaluation RF Source frequency (MHz) Threshold ERP (watts) 0.3-1.34 1,920 R 2 . 1.34-30 3,450 R 2 /f 2 . 30-300 3.83 R 2 . 300-1,500 0.0128 R 2 f. 1,500-100,000 19.2R 2 . China Certification ICT Co., Ltd (Dongguan) Report No.: CR221261979-00A Page 86 of 86 5.3 Measurement Result Operation Modes Frequency (MHz) λ/2π (mm) Distance (mm) Exemption ERP Maximum Conducted Power including Tune-up Tolerance (dBm) Antenna Gain (dBi) ERP (dBm) MPE- Based Exemption (mW)(dBm)(dBm) (mW) WLAN 2.4G 2412-2462 19.80 200 768 28.8524.6 3.90 26.35 431.52 Compliant WLAN 5G 5150-5250 9.22 200 768 28.8520 6.86 24.71 295.80 Compliant 5250-5350 9.08 200 768 28.8520 6.93 24.78 300.61 Compliant 5725-5850 8.73 200 768 28.8520 6.94 24.79 301.30 Compliant Note: 5G Antenna gain includes beamforming gain. The Maximum Conducted Power including Tune-up Tolerance was declared by manufacturer. WLAN 2.4G and 5G can transmit simultaneously. = ERP -2.4G /ERP th-2.4G +ERP -5G /ERP th-5G =431.52/768+301.30/768 =0.95<1 Result: The device compliant the Exemption at 20cm distances. ===== END OF REPORT =====

Test Report

SHENZHEN TENDA TECHNOLOGY CO.,LTD. Antenna Passive Test Report Product Name:MX15 Pro SHENZHEN TENDA TECHNOLOGY CO.,LTD. Test Information Product Name MX15 Pro product code Test Category Antenna passive test Test location S parameter (laboratory) Radiation parameter (Barron test room) Test date September 20, 2022 Tester Xiao Pengcheng, Barron staff Test environment Temperature : 24°C-28°C relative humidity: 56%-58% atmospheric pressure:100kPa-101kPa Test items Normal temperature electrical performance:□ √E A Return loss A□ √E A gain A□ √E A directional diagram A□ √E A Port isolation Analysis of test results The measured gain of the antenna in the 2.4G frequency band is greater than 3dBi, and the measured gain in the 5G frequency band is greater than 3dBi. The antenna gain meets the requirements. The antenna pattern also achieves omnidirectional coverage. Antenna echo loss<- 10dB, antenna matching is good. conclusion Antenna performance meets the index requirements SHENZHEN TENDA TECHNOLOGY CO.,LTD. Normal temperature electrical performance test results 2.4G antenna 0 order number Inspection items unit Performance index requirements Inspection results sentence Sample No: 1 frequency range MHz 2400-2500 2400-2500 OK 2 Gain dBi 4.26 2400 3.74 OK 2450 3.80 OK 2500 4.26 OK 3 Isolation degree dB ≤-15 2400 -23 OK 2450 -22 OK 2500 -23 OK 4 Return loss dB ≤-10 2400 -13 OK 2450 -12 OK 2500 -11 OK 2.4G antenna 1 order number Inspection items unit Performance index requirements Inspection results sentence Sample No: 1 frequency range MHz 2400-2500 2400-2500 OK 2 Gain dBi 3.95 2400 3.60 OK 2450 3.12 OK 2500 3.95 OK 3 Isolation degree dB ≤-15 2400 -23 OK 2450 -22 OK 2500 -23 OK 4 Return loss dB ≤-10 2400 -14 OK 2450 -14 OK 2500 -14 OK SHENZHEN TENDA TECHNOLOGY CO.,LTD. 5G a ntenna 0 order number Inspection items unit Performance index requirements Inspection results sentence Sample No: 1 frequency range MHz 5150-5850 5150-5850 OK 2 Gain dBi 3.80 5150 3.82 OK 5500 3.58 OK 5850 3.80 OK 3 Isolation degree dB ≤-15 5150 -27 OK 5500 -29 OK 5850 -30 OK 4 Return loss dB ≤-10 5150 -17 OK 5500 -14 OK 5850 -21 OK 5G a ntenna 1 order number Inspection items unit Performance index requirements Inspection results sentence Sample No: 1 frequency range MHz 5150-5850 5150-5850 OK 2 Gain dBi 3.90 5150 3.12 OK 5500 3.46 OK 5850 3.90 OK 3 Isolation degree dB ≤-15 5150 -27 OK 5500 -29 OK 5850 -30 OK 4 Return loss dB ≤-10 5150 -17 OK 5500 -17 OK 5850 -17 OK SHENZHEN TENDA TECHNOLOGY CO.,LTD. 5G a ntenna 2 order number Inspection items unit Performance index requirements Inspection results sentence Sample No: 1 frequency range MHz 5150-5850 5150-5850 OK 2 Gain dBi 3.94 5150 3.62 OK 5500 3.76 OK 5850 3.94 OK 3 Isolation degree dB ≤-15 5150 -27 OK 5500 -29 OK 5850 -30 OK 4 Return loss dB ≤-10 5150 -12 OK 5500 -11 OK 5850 -14 OK 5G a ntenna 3 order number Inspection items unit Performance index requirements Inspection results sentence Sample No: 1 frequency range MHz 5150-5850 5150-5850 OK 2 Gain dBi 3.83 5150 3.32 OK 5500 3.56 OK 5850 3.83 OK 3 Isolation degree dB ≤-15 5150 -33 OK 5500 -28 OK 5850 -29 OK 4 Return loss dB ≤-10 5150 -13 OK 5500 -15 OK 5850 -13 OK SHENZHEN TENDA TECHNOLOGY CO.,LTD. Test pattern 2.4G antenna 0 Frequency E Total. dB(dB) Efficiency( ) 2400MHz 3.74 78% 2410MHz 3.80 77% 2420MHz 3.75 76% 2430MHz 3.67 77% 2440MHz 3.76 79% 2450MHz 3.80 78% 2460MHz 3.89 77% 2470MHz 3.87 77% 2480MHz 4.09 78% 2490MHz 4.10 75% 2500MHz 4.26 73% 3D Radiation field type V PLANE H PLANE 2D Radiation field type SHENZHEN TENDA TECHNOLOGY CO.,LTD. Test pattern 2.4G antenna 1 Frequency E Total. dB(dB) Efficiency( ) 2400MHz 3.60 84% 2410MHz 3.49 84% 2420MHz 3.01 83% 2430MHz 3.00 84% 2440MHz 3.06 85% 2450MHz 3.12 84% 2460MHz 3.90 82% 2470MHz 3.63 83% 2480MHz 3.72 84% 2490MHz 3.83 81% 2500MHz 3.95 80% 3D Radiation field type V PLANE H PLANE 2D Radiation field type SHENZHEN TENDA TECHNOLOGY CO.,LTD. Test pattern 5G antenna 0 Frequency E Total. dB(dBi) Efficiency( ) 5150MHz 3.82 71% 5200MHz 3.86 71% 5250MHz 3.57 70% 5300MHz 3.93 73% 5350MHz 3.45 76% 5400MHz 4.17 74% 5450MHz 3.93 72% 5500MHz 3.58 72% 5550MHz 2.97 72% 5600MHz 3.31 74% 5650MHz 3.31 77% 5700MHz 3.22 77% 5750MHz 3.30 76% 5800MHz 3.30 72% 5850MHz 3.80 76% 3D Radi at ion field type 2D Radiation field type V PLANE H PLANE SHENZHEN TENDA TECHNOLOGY CO.,LTD. Test pattern 5G antenna 1 Frequency E Total. dB(dBi) Efficiency( ) 5150MHz 3.12 74% 5200MHz 3.34 71% 5250MHz 3.49 71% 5300MHz 3.53 71% 5350MHz 3.67 75% 5400MHz 3.96 76% 5450MHz 4.08 72% 5500MHz 3.46 78% 5550MHz 3.30 76% 5600MHz 2.87 75% 5650MHz 2.79 77% 5700MHz 3.11 71% 5750MHz 3.52 74% 5800MHz 3.73 76% 5850MHz 3.90 78% 3D Radiation field type 2D Radiation field type V PLANE H PLANE SHENZHEN TENDA TECHNOLOGY CO.,LTD. Test pattern 5G antenna 2 Frequency E Total. dB(dBi) Efficiency( ) 5150MHz 3.62 75% 5200MHz 3.64 72% 5250MHz 3.39 71% 5300MHz 3.21 73% 5350MHz 3.77 72% 5400MHz 3.53 74% 5450MHz 4.28 71% 5500MHz 3.76 74% 5550MHz 3.35 72% 5600MHz 3.57 73% 5650MHz 3.39 75% 5700MHz 3.18 72% 5750MHz 3.42 74% 5800MHz 3.24 73% 5850MHz 3.94 75% 3D Radiation field type 2D Radiation field type V PLANE H PLANE SHENZHEN TENDA TECHNOLOGY CO.,LTD. Test pattern 5G antenna 3 Frequency E Total. dB(dBi) Efficiency( ) 5150MHz 3.32 76% 5200MHz 3.54 73% 5250MHz 3.56 74% 5300MHz 3.78 75% 5350MHz 3.39 71% 5400MHz 3.51 73% 5450MHz 4.26 73% 5500MHz 3.56 76% 5550MHz 3.35 71% 5600MHz 3.53 72% 5650MHz 3.29 73% 5700MHz 3.26 74% 5750MHz 3.78 72% 5800MHz 3.84 72% 5850MHz 3.83 72% 3D Radiation field type 2D 辐射场型 V PLANE H PLANE SHENZHEN TENDA TECHNOLOGY CO.,LTD. S Parameter diagram 2.4GAntenna 0 return loss test 2.4G Antenna 1 return loss test SHENZHEN TENDA TECHNOLOGY CO.,LTD. 5G antenna 0 return loss test 5G Antenna 1 Return Loss Test SHENZHEN TENDA TECHNOLOGY CO.,LTD. 5G antenna 2 return loss test 5G antenna 3 return loss test SHENZHEN TENDA TECHNOLOGY CO.,LTD. 2.4G antenna isolation test 5G antenna isolation test (antenna 0 vs antenna 1) 5G Antenna Isolation…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Applicant: SHENZHEN TENDA TECHNOLOGY CO.,LTD. Address: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 FCC ID: V7TMESH15XP Product Name: AX5400 Whole Home Mesh Wi-Fi 6 System Model Number: Mesh15XP, MX15 Pro, EX15 Pro, EM15 Pro Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR221261979-00A Date Of Issue: 2023/3/17 Reviewed By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR221261979-00A Page 2 of 86 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR221261979-00A Page 3 of 86 CONTENTS T EST FACILITY .......................................................................................................................................... 2 DECLARATIONS .......................................................................................................................................... 2 DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 8 1.2.1 EUT Operation Condition: ............................................................................................................................. 8 1.2.2 Support Equipment List and Details .............................................................................................................. 8 1.2.3 Support Cable List and Details ...................................................................................................................... 8 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 9 1.3 MEASUREMENT UNCERTAINTY ........................................................................................................ 10 2. SUMMARY OF TEST RESULTS .......................................................................................... 11 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 12 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 12 3.1.1 Applicable Standard ..................................................................................................................................... 12 3.1.2 EUT Setup.................................................................................................................................................... 13 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 13 3.1.4 Test Procedure ............................................................................................................................................. 14 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 14 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 15 3.2.1 Applicable Standard ..................................................................................................................................... 15 3.2.2 EUT Setup.................................................................................................................................................... 15 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 16 3.2.4 Test Procedure ............................................................................................................................................. 16 3.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 16 3.3 MINIMUM 6 DB BANDWIDTH: ...........................…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emissions Front View Conducted Emissions Side View Radiated Emission Below 1GHz View Radiated Emission Above 1GHz View

Contact Information

Applicant

Shen Yue(Engineer)
[email protected]86-755-27657098Fax: 866-755-27657178

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Tanie Ou
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz284.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This product is capable of 2x2 MIMO operating and supports 20 MHz and 40 MHz bandwidth modes.

Other Applications from SHENZHEN TENDA TECHNOLOGY CO., LTD.

AX1800 Wi-Fi 6 Dual-Band USB Adapter - FCC ID V7TU18V3 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TU18V3

AX1800 Wi-Fi 6 Dual-Band USB Adapter

Aug 26, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
AX3000 Dual-Band Gigabit Wi-Fi Range Extender, AX1800 Dual-Band Gigabit Wi-Fi Range Extender - FCC ID V7TA33V2 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TA33V2

AX3000 Dual-Band Gigabit Wi-Fi Range Extender, AX1800 Dual-Band Gigabit Wi-Fi Range Extender

Aug 25, 2026

Equipment Class

DTS - Digital Transmission System
6MP Dual-lens Linkage Wi-Fi Pan/Tilt Camera - FCC ID V7TCH9V2 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCH9V2

6MP Dual-lens Linkage Wi-Fi Pan/Tilt Camera

Jul 20, 2026

Equipment Class

DTS - Digital Transmission System
3MP Wi-Fi Pan/Tilt Camera - FCC ID V7TCH3V21 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCH3V21

3MP Wi-Fi Pan/Tilt Camera

Jul 14, 2026

Equipment Class

DTS - Digital Transmission System
3MP Security Pan/Tilt Camera - FCC ID V7TCP3P1 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCP3P1

3MP Security Pan/Tilt Camera

Jun 30, 2026

Equipment Class

DTS - Digital Transmission System