FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Murata Manufacturing Co., Ltd./
  3. VPYLBEE5XV1XA

VPYLBEE5XV1XACommunication Module

Murata Manufacturing Co., Ltd.
Communication Module - FCC ID VPYLBEE5XV1XA - Murata Manufacturing Co., Ltd.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Feb 16, 2021
Application Purpose
Original Equipment
Date of Application
Jan 25, 2021
Equipment Note
Communication Module
Frequency Range
5745.00000000 - 5825.00000000
Company
Murata Manufacturing Co., Ltd.
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 09 October 2020 LBEE5XV1XA User Manual for FCC *If it is difficult to describe this statement on the host product due to the size, please describe in the User's manual. please describe in the user's manual and also either describe on the device packaging or on a removable label attached to thedevice. or Contains Transmitter Module FCC ID:VPYLBEE5XV1XAContains FCC ID: VPYLBEE5XV1XA This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device maynot cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ●The following information must be indicated on the host device of this module. ModelName:LBEE5XV1XA, LBEE5XV2BA, LBEE5XV1ZA FCC ID:VPYLBEE5XV1XA Since this module is not sold to general end users directly, there is no user manual of module. For the details about this module, please refer to the specification sheet of module. This module should be installed in the host device according to the interface specification (installation procedure) The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the end user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as shown in User manual. 2 Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 09 October 2020 LBEE5XV1XA User Manual for FCC This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. ●The following statements must be described on the user manual of the host device of this module; FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. When installing it in a mobile equipment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment should be installed and operated keeping the radiator at least 20cm or more away from person’s body. When installing it in a portable equipment. It is necessary to take a SAR test with your set mounting this module. Class II permissive change application is necessary using the SAR report. Please contact Murata. Note) Portable equipment : Equipment for which the spaces between human body and antenna are used within 20cm. Mobile equipment : Equipment used at position in which the spaces between human body and antenna exceeded 20cm. 3 Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 09 October 2020 LBEE5XV1XA User Manual for FCC Compliance with FCC requirement 15.407(c) Data transmission is always initiated by software, which is the passed down through the MAC, through the digital and analog baseband, and finally to the RF chip. Several special packets are initiated by the MAC. These are the only ways the digital baseband portion will turn on the RF transmitter, which it then turns off at the end of the packet. Therefore, the transmitter will be on only while one of the aforementioned packets is being transmitted. In other words, this device automatically discontinue transmission in case of either absence of information to transmit or operational failure. Frequency Tolerance: ±20 ppm

Cover Letter(s)

Date: 11/17/2020 DTS-UNII Device Declaration Letter To whom it may concern, we declare below featured for equipment authorization regarding FCC ID: VPYLBEE5XV1XA (1) DFS Device -- ☐ Master,(DFS Master) ☐ Client with Radar detection capability(DFS Master), ☒ Client without radar detection capability,(DFS Salve) ☐ N/A (2) Active / Passive Scanning Frequency Band(MHz) Active Scanning (able to select a channel and initiate a network by sending enabling signals to other devices) passive scanning (not able to initiate a network) Non Applicable 2412 - 2462 ☒ Yes , ☐ No ☐ Yes , ☒ No ☐ 5150 - 5250 ☒ Yes , ☐ No ☐ Yes , ☒ No ☐ 5250 - 5350 ☐ Yes , ☒ No ☒ Yes , ☐ No ☐ 5470 - 5725 ☐ Yes , ☒ No ☒ Yes , ☐ No ☐ 5725 - 5850 ☒ Yes , ☐ No ☐ Yes , ☒ No ☐ (3) Country code selection ability - ☒ Yes , ☐ No If yes, pls explain how it was implemented : Country code is factory set in the UI and cannot be changed by end users. (4) Meet 15.202 requirement - ☒ Yes , ☐ No pls check below : ☐ A master device is defined as a device operating in a mode in which it has the capability to transmit without receiving an enabling signal. In this mode it is able to select a channel and initiate a network by sending enabling signals to other devices. ☒ A client device is defined as a device operating in a mode in which the transmissions of the device are under control of the master. A device in client mode is not able to initiate a network. Signature: Name (Printed): Kenji Hayashikoshi Title: Senior Manager On behalf of Company: Murata Manufacturing Co., Ltd. Telephone: +81-75-955-6173 Address: 10-1, Higashikotari 1-chome, Nagaokakyo-shi, Kyoto 617-8555 Japan

Cover Letter(s)

Declaration Date: January 13, 2021 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We declare that this equipment (Product Name: Communication Module, FCC ID: VPYLBEEXVIXA) complies with e-CFR Title 47 Part 2.925 (f), as it is too small to be labeled with FCC ID (smaller than 4 points). Hence the FCC ID is placed in user manual instead of being affixed on the equipment. Thank you, Name: Kenji Hayashikoshi Title: Senior Manager Telephone: +81-75-955-6736 Signature: ________________

Cover Letter(s)

RF_160, Issue 04 Declaration of Authorization We Name: Murata Manufacturing Co., Ltd. Address: 10-1, Higashikotari 1-chome, Nagaokakyo-shi, City: Kyoto 617-8555 Country: Japan Declare that: Name Representative of agent: Jim Chang Agent Company name: SGS Taiwan Ltd. Address: 134, Wu Kung Road, Wu ku Industrial Zone TW- New Taipei City 24803 City: New Taipei City Country: Taiwan is authorized to apply for Certification of the following product(s): Product description: Communication Module Type designation: LBEE5XV1XA, LBEE5XV2BA, LBEE5XV1ZA Trademark: MURATA Validity/ expiry date: 11/17/2021 on our behalf, Date: 11/17/2020 City: Kyoto Name: Kenji Hayashikoshi Function: Senior Manager Signature:

Cover Letter(s)

FCC, Request for non-disclosure Date: 16-Jul-10 RF_501, Issue 6 Page 1 of 1 Company Name: Murata Manufacturing Co., Ltd. Address: 10-1, Higashikotari 1-chome, Nagaokakyo-shi, City: Kyoto 617-8555 Country: Japan To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: VPYLBEE5XV1XA Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Planned Release Date STC: 180 days (notes 2, 3, 4, 5) Date: 17/11/2020 Name and signature of applicant: Kenji Hayashikoshi Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

Cover Letter(s)

RF_734_02 04 April 16 Modular Approval Request FCC (KDB 996369 D01 & Part 15.212) FCC ID: VPYLBEE5XV1XA Items to be covered by Single modular transmitters. Answer from applicant 1. The modular transmitter must have its own RF shielding. The EUT provides the RF shielding. 2. The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with Part 15 requirements under conditions of excessive data rates or over- modulation. The module and data input(s) are buffered. The EUT has buffered data inputs, it is integrated in IC chip. 3. The modular transmitter must have its own power supply regulation. No. The lower limit of the supply voltage to the module is 3.0V, but the voltage inside the IC needs to be 3.3V. For products that mount modules, incorporate power supply regulation such that the lower limit of the supply voltage to the module is 3.3V 4. The modular transmitter must comply with the antenna requirements of Section 15.203 and 15.204(b)(c). The antenna must either be permanently attached or employ a “unique” antenna coupler (at all connections between the module and the antenna, including the cable). The EUT meets the FCC antenna Requirements. Instructions are described in Operational Description. 5. The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing. This is intended to demonstrate that the module is capable of complying with Part 15 emission limits regardless of the device into which it is eventually installed. The modular transmitter has been performed the testing in a state of being installed on a test jig board simulating the board of the installed end product. It has been performed the testing as a stand-alone and then confirmed the compliance. The module and antenna will be mounted on a board similar to the one shown in the test set photo, and the board will be installed in the end product. 6. The modular transmitter must be equipped with either a permanently affixed label or must be capable of electronically displaying its FCC identification number in accordance with 15.212 (a)(1)(vi)(A) / (B). The FCC ID is marked with a laser on the metal case as shown in Label Drawing & Location. 7. The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. For example, there are very strict operational and timing requirements that must be met before a transmitter is authorized for operation under Section 15.231. For instance, data transmission is prohibited, except for operation under Section 15.231(e), in which case there are separate field strength level and timing requirements. Compliance with these requirements must be assured. The EUT is compliant with all applicable FCC rules. Details instructions for maintaining compliance are given in the User Manual. 8. The modular transmitter must comply with any applicable RF exposure requirements. For example, FCC Rules in Sections 1.1310, 2.1091, 2.1093, and specific Sections of Part 15, including 15.319(i), 15.407(f), 15.253(f) and 15.255(g), require that Unlicensed PCS, UNII and millimeter wave devices perform routine environmental evaluation for RF Exposure to demonstrate compliance. In addition, spread spectrum transmitters operating under Section 15.247 are required to address RF Exposure compliance. Modular transmitters approved under other Sections of Part 15, when necessary, may also need to address certain RF Exposure concerns, typically by providing specific installation and operating instructions for users, installers and other interested parties to The EUT is comply with RF exposure re requirement. RF exposure is addressed in the User Manual RF_734_02 04 April 16 ensure compliance. Items to be covered by Split modular transmitters. Answer from applicant 1. The modular transmitter must comply with all requirements of a single modular transmitter except for items (1) & (5) of the above single modular approval requirements. N/A 2. Only the radio front end must be shielded. The physical crystal and tuning capacitors may be located external to the shielded radio elements. The interface between the split sections of the modular system must be digital with a minimum signalling amplitude of 150 mV peak-to-peak. N/A 3. Control information and other data may be exchanged between the transmitter control elements and radio front end. N/A 4. The sections of a split modular transmitter must be tested installed in a host device(s) similar to that which is representative of the platform(s) intended for use. N/A 5. Manufacturers must ensure that only transmitter control elements and radio front end components that have been approved together are capable of operating together. The transmitter module must not operate unless it has verified that the installed transmitter control elements and radio front end have been authorized together. Manufacturers may use means including, but not limited to, coding in hardware and electronic signatures in software to meet these requirements, and must describe the methods in their application for equipment authorization. N/A Note: A limited modular approval (LMA) may be granted for single or split modular transmitters that comply partially with the requirements above. Name and surname of applicant (or authorized representative): Kenji Hayashikoshi Date: 11/17/2020 Signature: ___________________________

External Photos

EUT Photo No.: ER/2020/90106~111-P Page: 1 of 3 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group PHOTOGRAPHS OF EUT Front View of EUT Back View of EUT EUT Photo No.: ER/2020/90106~111-P Page: 2 of 3 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Front View of Host_2ANT Back View of Host_2ANT EUT Photo No.: ER/2020/90106~111-P Page: 3 of 3 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Front View of Host_3ANT Back View of Host_3ANT

ID Label/Location Info

1 Copyright © Murata Manufacturing Co., Ltd. All rights reserved. 25 January 2021 Unit: mm muRatalogoHightWidth 1.6mm7.0mm 2d Matrix code 14 x 14 cell 1cell = 0.2mm□ ModelNoHightWidthInterval 0.8mm0.8mm0.1mm Inspection No HightWidthInterval 0.8mm0.8mm0.1mm 999999999Serial No HightWidthInterval 0.8mm0.8mm0.1mm Direction Mark Φ0.6mm There is no space to describe the FCC ID/ ISED IC Number. Therefore it is described on the manual. LBEE5XV1XA SSXXXXXXX φ0.6mm 2.8 2.8 0.8 0.8 11.4 8.9 LBEE5XV1XA SSXXXXXXX 999999999 0.8 1.6 7.0 0.8 0.8 0.8 0.3 0.3 0.3 0.3 Marking Area LBEE5XV1XA Label

Internal Photos

EUT Photo No.: ER/2020/90106~111-P Page: 1 of 1 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group INTERNAL PHOTOGRAPHS OF EUT Internal View of EUT – 1 Internal View of EUT – 2

RF Exposure Info

Report No: ER/2020/90111 Page: 1 of 11 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group RF EXPOSURE REPORT OF Applicant: Murata Manufacturing Co., Ltd. 10-1, Higashikotari 1-chome, Nagaokakyo-shi, Kyoto 617- 8555 Japan Product Name: Communication Module Brand Name: muRata FCC Model No.: LBEE5XV1XA, LBEE5XV2BA, LBEE5XV1ZA IC Model No.: LBEE5XV1XA_3ANT, LBEE5XV1XA_2ANT, LBEE5XV2BA_3ANT, LBEE5XV2BA_2ANT, LBEE5XV1ZA_3ANT, LBEE5XV1ZA_2ANT Model Difference: Please refer to the tables on page 5 for further details. Report Number: ER/2020/90111 FCC ID: VPYLBEE5XV1XA IC: 772C-LBEE5XV1XA FCC Rule Part: Part 2.1091 IC Rule: RSS-102 issue 5 Mar. 19, 2015 Issue Date: Jan. 07, 2021 Date of Test: This report is only calculated based on the test results, there will be no date of test. Date of EUT Received: Sep. 22, 2020 We hereby certify that: The above equipment was verified by SGS Taiwan Ltd. The evaluation in this report is in compliance with the above rule(s). The results of this report relate only to the sample identified in this report. Approved By: John Yeh / Asst. Manager Report No: ER/2020/90111 Page: 2 of 11 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Revision History Report Number Revision Description Issue Date Remark ER/2020/90111 Rev.00 Original. Jan. 07, 2021 Revised By: Violetta Tang Note: 1、 Multiple Model numbers or Trademarks The variant model numbers are assessed as identical in hardware and software to each other, hence all variants are fully covered by the test results in this test report without further verification test. 2、 Disclaimer Variant information among model numbers is provided by the applicant, test results of this report are applicable to the sample EUT received. 3、 Disclaimer Antenna information is provided by the applicant, test results of this report are applicable to the sample EUT received. Report No: ER/2020/90111 Page: 3 of 11 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification …

Text truncated - open the document above for the full version.

Test Report

Report No.: ER/2020/90109 Page: 1 of 240 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路 134 號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT Applicant: Murata Manufacturing Co., Ltd. 10-1, Higashikotari 1-chome, Nagaokakyo-shi, Kyoto 617- 8555 Japan Product Name: Communication Module Brand Name: muRata FCC Model No.: LBEE5XV1XA, LBEE5XV2BA, LBEE5XV1ZA IC Model No.: LBEE5XV1XA_3ANT, LBEE5XV1XA_2ANT, LBEE5XV2BA_3ANT, LBEE5XV2BA_2ANT, LBEE5XV1ZA_3ANT, LBEE5XV1ZA_2ANT Model Difference: Please refer to the tables on page 5 for further details. Report Number: ER/2020/90109 FCC ID: VPYLBEE5XV1XA IC: 772C-LBEE5XV1XA FCC Rule Part: §15.407, Cat: NII ISED RSS: RSS-247 issue 2 Feb. 2017 Issue Date: Jan. 07, 2021 Date of Test: Sep. 22, 2020 ~ Nov. 30, 2020 Date of EUT Received: Sep. 22, 2020 We hereby certify that: The above equipment was tested by SGS Taiwan Ltd. Central RF Lab The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10: 2013 and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits. The test results of this report relate only to the tested sample ide…

Text truncated - open the document above for the full version.

Contact Information

Applicant

KENJI HAYASHIKOSHI(SENIOR MANAGER)
[email protected]81-75-955-6173Fax: 81-75-955-7097

Technical Contact

SGS Taiwan LtdJim Chang
[email protected]886 2 2299 3279

134, Wu Kung Road, WuKu Industrial Zone · Taiwan

Non-Technical Contact

SGS Taiwan LtdJim Chang
[email protected]886 2 2299 3279

Test Firm

SGS Taiwan Ltd. Central RF LabRyan WANG
[email protected]+886-2-2299-3279

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.83 GHz110.00 mW
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
Limited Modular Approval. Output power listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40/80 MHz bandwidth modes.

Other Applications from Murata Manufacturing Co., Ltd.

VPYLB2EA003

Communication Module

Sep 01, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
VPYLBWA0ZZ2JM

Communication Module

Mar 11, 2026

Equipment Class

DTS - Digital Transmission System
Wireless Vibration Sensor Unit - FCC ID VPYLB2TG - Murata Manufacturing Co., Ltd.
VPYLB2TG

Wireless Vibration Sensor Unit

May 20, 2025

Equipment Class

DTS - Digital Transmission System
VPYLBEE5WV2GF

Communication Module

Jun 20, 2024

Equipment Class

DTS - Digital Transmission System
LoRa Module - FCC ID VPYLB2GT - Murata Manufacturing Co., Ltd.
VPYLB2GT

LoRa Module

Mar 25, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter