Murata Manufacturing Co., Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 26, 2014
Application Purpose
Original Equipment
Date of Application
Jun 26, 2014
Equipment Note
Communication Module
Frequency Range
2402.00000000 - 2480.00000000
Company
Murata Manufacturing Co., Ltd.
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 2014/5/29 For OEM integration only – device cannot be sold to general public. Therefore we will ask OEM to include the following statements required by FCC on the product and in the Installation manual Notice. ZF / ZW Installation Manual “FCC ID and IC Number” of these products are as follows. FCC ID:VPYLBZF IC Number:772C-LBZF Model : ZF Model : ZW Contents 1.Land Pattern(Recommended) 2.Supply Voltage 3.Install 4.Antenna 5.Notice 6 5. Notice Please describe the following warning on the final product which contains this module. Contains Transmitter Module FCC ID:VPYLBZF Contains FCC ID:VPYLBZF or 2014/5/29 For FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For IC Contains Transmitter Module IC: 772C-LBZF Contains IC: 772C-LBZF or 7 When installing it in a portable equipment When installing it in a mobile equipment Please describe the following warning to the manual. Note) Portable equipment : Equipment for which the spaces between human body and antenna are used within 20cm. Mobile equipment : Equipment used at position in which the spaces between human body and antenna exceeded 20cm. 2014/5/29 FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluation (MPE). This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment has very low levels of RF energy that are deemed to comply without testing of specific absorption ratio (SAR). For FCC 8 Please describe the following warning to the manual. 2014/5/29 This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. For IC 9 When installing it in a mobile equipment Please describe the following warning to the manual. 2014/5/29 This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment and meets RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluation (MPE). For IC Cet équipement est conforme aux limites d’exposition aux rayonnements énoncées pour un environnement non contrôlé et respecte les règles d’exposition aux fréquences radioélectriques (RF) CNR-102 de l’IC. Cet équipement émet une énergie RF très faible qui est considérée conforme sans évaluation de l’exposition maximale autorisée. 10 When installing it in a portable equipment Please describe the following warning to the manual. Note) Portable equipment : Equipment for which the spaces between human body and antenna are used within 20cm. Mobile equipment : Equipment used at position in which the spaces between human body and antenna exceeded 20cm. 2014/5/29 This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment and meets RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment should be installed and operated keeping the radiator at least 20cm or more away from person’s body (※). For IC Cet équipement est conforme aux limites d’exposition aux rayonnements énoncées pour un environnement non contrôlé et respecte les règles d’exposition aux fréquences radioélectriques (RF) CNR-102 de l’IC. Cet équipement doit être installé et utilisé en gardant une distance de 20 cm ou plus entre le dispositif rayonnant et le corps [※].

External Photos

ZF / ZW Please refer to the label figure for the contents of t he label notation. Hight 1 0mm MAX Hight 1 . 0mm MAX 5.4mm Module(Top ‐‐‐ Shielded) Module(Back) 1/3 2014/05/20 ZF / ZW Shielded except Antenna part Module (Bird’s ‐ eyes view) 2/3 2014/05/20

ID Label/Location Info

ZF :Product Name KM1234567 :The information of Lot trace :Direction display FCC ID: VPYLBZF Label Design to FCC Since there is no space which indicates FCC ID, FCC ID is indicated in a manual. (mm) 2D Code (For Murata internal use only) Pin #1 Identifier Control Code (In case If needed. For Murata Internal use only.) Model Number Control Code (Murata Internal Use Only)

Internal Photos

ZF / ZW Internal Photo Module(Top ‐‐‐ Unshielded) 3/3

RF Exposure Info

UL Japan, Inc. Ise HQ EMC Lab 4383-326 Asama-cho, Ise-shi, Mie 516-0021 Japan T:: +81.596.24.8999 / F:: +81.596.24.8124 / W:: ul.com/jp June 3, 2014 UL Japan, Inc. 4383-326 Asama-cho, Ise-shi, Mie 516-0021 Japan FCC ID: VPYLBZF To whom it may concern, We, UL Japan, Inc, hereby declare that Communication Module, model: ZF (FCC ID: VPYLBZF) of Murata Manufacturing Co., Ltd. is exempt from RF exposure SAR evaluation as its output power meets the exclusion limits stated in KDB 447498D01(V05). KDB 447498D01(V05) has the following exclusion for portable devices: The 1g and 10g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where •f(GHz) is the RF channel transmit frequency in GHz •Power and distance are rounded to the nearest mW and mm before calculation •The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. This device has f = 2.48 GHz and distance = 5 mm (minimum separation distance: 5mm was used in the calculation) and the maximum tune-up tolerance limit was 1 mW. So for this device: 1 mW[maximum tune-up tolerance limit]/5 mm[minimum separation distance]*√2.48 = 0.3 *This is less than 3.0, so no SAR is required. Thank you for your attention to this matter. Takayuki Shimada Engineer of Ise HQ EMC Lab. Consumer Technology Division UL Japan, Inc.

Test Report

Test report No. : 10300021H-A Page : 2 of 37 Issued date : May 23, 2014 FCC ID : VPYLBZF UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 REVISION HISTORY Original Test Report No.: 10300021H-A Revision Test report No. Date Page revised Contents - (Original) 10300021H-A May 23, 2014 - - Test report No. : 10300021H-A Page : 3 of 37 Issued date : May 23, 2014 FCC ID : VPYLBZF UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ......................................................................................................... 4 SECTION 2: Equipment under test (E.U.T.) ........................................................................................... 4 SECTION 3: Test specification, procedures & results ............................................................................ 5 SECTION 4: Operation of E.U.T. during testing .................................................................................... 8 SECTION 5: Conducted Emission .......................................................................................................... 10 SECTION 6: Radiated Spurious Emission ............................................................................................ 11 SECTION 7: Antenna Terminal Conducted Tests ................................................................................ 12 APPENDIX 1: Data of EMI test .............................................................................................................. 13 Conducted Emission ......................................................................................................................... 13 6dB Bandwidth ................................................................................................................................. 16 Maximum Peak Output Power .......................................................................................................... 18 Radiated Spurious Emission ............................................................................................................. 19 Conducted Spurious Emission .......................................................................................................... 26 Power Density ................................................................................................................................... 29 99%Occupied Bandwidth ................................................................................................................. 31 APPENDIX 2: Test instruments ............................................................................................................. 32 APPENDIX 3: Photographs of test setup ............................................................................................... 33 Conducted Emission ......................................................................................................................... 33 Radiated Spurious Emission ............................................................................................................. 35 Worst Case Position .......................................................................................................................... 37 Test report No. : 10300021H-A Page : 4 of 37 Issued date : May 23, 2014 FCC ID : VPYLBZF UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : Murata Manufacturing Co., Ltd. Address : 10-1, Higashikotari 1-chome Nagaokakyo-shi, Kyoto, 617-8555, Japan Telephone Number : +81-75-955-6708 Facsimile Number : +81-75-955-6634 Contact Person : Yuichi Ito SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Communication Module Model No. : ZF Serial No. : Refer to Clause 4.2 Rating : DC 3.0V Receipt Date of Sample : April 14, 2014 Country of Mass-production : Japan and China Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product Description General Specification Clock frequency(ies) in the system : 16MHz Radio Specification [Bluetooth (Ver. 4.0)] Radio Type : Transceiver Frequency of Operation : 2402-2480MHz Modulation : GFSK Power Supply (inner) : DC 1.41V Antenna type : Monopole antenna Antenna Gain : 2.7dBi Variant model ZF has valiant model: ZW. The difference between these models are shown below; - ZF: Four-layered board - ZW: Six-layered board Test report No. : 10300021H-A Page : 5 of 37 Issued date : May 23, 2014 FCC ID : VPYLBZF UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test Specification Test Specification : FCC Part 15 Subpart C: 2014, final revised on March 6, 2014 and effective April 7, 2014 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.207 Conducted limits Section 15.247 Operation within the bands 902-928MHz, 2400-2483.5MHz, and 5725-5850MHz 3.2 Procedures and results Item Test Procedure Specification Worst margin Results Remarks Conducted Emission FCC: ANSI C63.4:2003 7. AC powerline Conducted Emission measurements FCC: Section 15.207 QP 23.7dB, 0.15349MHz, L AV 18.4dB, 24.93722MHz, N Complied- IC: RSS-Gen 7.2.4 IC: RSS-Gen 7.2.4 6dB Bandwidth FCC: "Guidance for Performing Compliance Measurements on Digital Transmission Systems (DTS) Operating Under §15.247(issued on April 9, 2013)" FCC: Section 15.247(a)(2) See data. CompliedConducted IC: RSS-Gen 4.6.2 IC: RSS-210 A8.2(a) Maximum Peak Output Power FCC: "Guidance for Performing Compliance Measurements on Digital Transmi…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report No. : 10300021H-A Page : 33 of 37 Issued date : May 23, 2014 FCC ID : VPYLBZF UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 APPENDIX 3: Photographs of test setup Conducted Emission (Model No.: ZF) Photo 1 Photo 2 Test report No. : 10300021H-A Page : 34 of 37 Issued date : May 23, 2014 FCC ID : VPYLBZF UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Conducted Emission (Model No.: ZW) Photo 1 Photo 2 Test report No. : 10300021H-A Page : 35 of 37 Issued date : May 23, 2014 FCC ID : VPYLBZF UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Radiated Spurious Emission (Model No.: ZF) Photo 1 Photo 2 Test report No. : 10300021H-A Page : 36 of 37 Issued date : May 23, 2014 FCC ID : VPYLBZF UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Radiated Spurious Emission (Model No.: ZW) Photo 1 Photo 2 Test report No. : 10300021H-A Page : 37 of 37 Issued date : May 23, 2014 FCC ID : VPYLBZF UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Worst Case Position Above 1GHz (Horizontal: Y-axis/ Vertical:Z-axis) Below 1GHz (Horizontal: X-axis/ Vertical:X-axis) X-axis Y-axis Z-axis End of Report

Contact Information

Applicant

KENJI HAYASHIKOSHI(SENIOR MANAGER)
[email protected]81-75-955-6173Fax: 81-75-955-7097

Technical Contact

UL Japan, Inc.Takayuki Shimada
[email protected]81-596-24-8999

4383-326 Asama-cho, Ise-shi · Mie-ken · Japan

Test Firm

UL Japan, Inc. Head office EMC Lab.Tetsuya Hashimoto
[email protected]+81-596-24-8116Fax: +81-596-24-8095

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Limited Modular approval. Output power listed is Conducted. Compliance of this device in all final host configurations is the responsibility of the Grantee. OEM integrators and end-users must be provided with specific operating instructions for satisfying RF exposure compliance. OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. This module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided.

Other Applications from Murata Manufacturing Co., Ltd.

VPYLB2EA003

Communication Module

Sep 01, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
VPYLBWA0ZZ2JM

Communication Module

Mar 11, 2026

Equipment Class

DTS - Digital Transmission System
Wireless Vibration Sensor Unit - FCC ID VPYLB2TG - Murata Manufacturing Co., Ltd.
VPYLB2TG

Wireless Vibration Sensor Unit

May 20, 2025

Equipment Class

DTS - Digital Transmission System
VPYLBEE5WV2GF

Communication Module

Jun 20, 2024

Equipment Class

DTS - Digital Transmission System
LoRa Module - FCC ID VPYLB2GT - Murata Manufacturing Co., Ltd.
VPYLB2GT

LoRa Module

Mar 25, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter