TX07 Manual Features: ` Temperature measurement ranges: -20°C (-4°F) ~ 60°C (140°F) ` Temperature alternatively in ºC or ºF. ` Humidity measurable range: 20%RH ~ 95%RH ` Data transmission frequency: 433 .92MHz ` Wirele ss range: max. 60 m (open area) ` Wireless ch annel: 1 channel ` Battery:2 x LR6 AA Parts description: Part A –LCD Display: A1: Temperature A2: RF icon A3: Channel icon A4: Humidity A5: Low battery icon Part B –Button & switch: B1: ºC/ºF button B2: TX button B3: channel Selection switch Part C –Appearance: C1: Signal LED C2: Battery compartment cover C3: Eyebolt C4: Stand C5: battery compartment TX07 Manual Initial operation: ` Open the battery compartment on the back of the wireless transmitter by sliding the battery cover in the direction of the arrow. ` Insert the new batteries, type LR06, in the battery compartment. Check the polarity of the battery during insertion. This is indicated in the battery compartment. ` Close the battery cover. ` The signal LED at the front of the outdoor sensor will briefly light up. The signal LED will then flash about twice a minute, indicating wireless transmission. Set the transmission channel: ` Sliding the CH switch inside the remote’s battery compartment to select Channel 1 or Channel 2 or Channel 3. The Channel number assigned will appear on the remote’s LCD screen. °C/°F temperature display: ` The temperature is displayed either in °C or °F. Briefly pressing the “°C/°F” button inside the remote’s battery compartment allows you to switch between the individual models. Manual transmit signal ` Pressing the “TX” button inside the remote’s battery compartment 1 times, the wireless transmitter will immediately transmit the 1 wireless data, The Signal LED and an RF icon on the remote will flash when a signal is sent. FCC Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
MET Laboratories TCB - Samples Agent Authorization Letter 2015-08-14 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Most Technology Service Co., Ltd. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Name: Jianxin Shi Position: Manager Company Name: Fuzhou Emax Electronic Co., Ltd. Address: Building #12-#16, Cangshan Industrial Area, Juyuanzhou, Jinshan District, Fuzhou, Fuzhou E-Mail: [email protected]
MET Laboratories TCB - Samples Long Term Confidentiality Request Letter 2015-08-14 MET Laboratories, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (Outdoor Remote Sensor/ TX07) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - e.g. TX07_Block diagram - e.g. TX07_SCH - e.g. TX07_Operation Description required to be submitted with this application be permanently withheld from public review. SPECIFY REASON FOR REQUEST (i.e. the above documents are company proprietary information that could never get into the possession of your competition). Please contact me if there is any information you may need. Sincerely, Name: Jianxin Shi Position: Manager Company Name: Fuzhou Emax Electronic Co., Ltd. Address: Building #12-#16, Cangshan Industrial Area, Juyuanzhou, Jinshan District, Fuzhou, Fuzhou E-Mail: [email protected]
FCC ID: WEC-1503 Model No.: TX07 FRONT VIEW OF SAMPLE BACK VIEW OF SAMPLE FCC ID: WEC-1503 Model No.: TX07 LEFT VIEW OF SAMPLE RIGHT VIEW OF SAMPLE FCC ID: WEC-1503 Model No.: TX07 TOP VIEW OF SAMPLE BOTTOM VIEW OF SAMPLE FCC ID: WEC-1503 Model No.: TX07 PHOTO OF THE ENTIRE SAMPLE
23mm 24mm
FCC ID: WEC-1503 Model No.: TX07 INTERNAL PHOTO OF SAMPLE – 1 INTERNAL PHOTO OF SAMPLE – 2 FCC ID: WEC-1503 Model No.: TX07 INTERNAL PHOTO OF SAMPLE – 3 INTERNAL PHOTO OF SAMPLE – 4 FCC ID: WEC-1503 Model No.: TX07 BATTERY PHOTO OF SAMPLE – 5 BATTERY PHOTO OF SAMPLE – 6 Temperature sensor Humidity sensor
FCC 47 CFR PART 15 SUBPART C TEST REPORT For Applicant : FUZHOU EMAX ELECTRONIC CO., LTD Address : Building #12-#16, CangShan Industrial Area, JuYuanZhou JinShan District, FuZhou, China. Product Name : Outdoor Remote Sensor Model Name : TX07 Brand Name : TAYLOR FCC ID : WEC-1503 Report No. : MTE/DYY/A15080988 Date of Issue : Aug. 10, 2015 Issued by :Most Technology Service Co., Ltd. Address : No.5, Langshan 2nd Road, North District, Hi-tech Industrial Park, Nanshan, Shenzhen, Guangdong, China Tel : 86-755-86026850 Fax : 86-755-26013350 The report consists 22 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by MOST. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. FCC ID: WEC-1503 Report No.: MTE/DYY/A15080988 Page 2 of 22 TABLE OF CONTENTS 1.VERIFICATION OF CONFORMITY ........................................................................................ 3 2. GENERAL INFORMATION....................................................................................................... 4 2.1 Product Information ................................................................................................................ 4 2.2 Objective ................................................................................................................................ 5 2.3 Test Standards and Results .................................................................................................... 5 2.4 Environmental Conditions....................................................................................................... 5 3. TEST METHODOLOGY ........................................................................................................... 6 3.1 TEST FACILITY...................................................................................................................... 6 3.2 GENERAL TEST PROCEDURES .......................................................................................... 6 4 SETUP OF EQUIPMENT UNDER TEST .................................................................................. 8 4.1 SETUP CONFIGURATION OF EUT....................................................................................... 8 4.2 SUPPORT EQUIPMENT ........................................................................................................ 8 4.3 TEST EQUIPMENT LIST........................................................................................................9 5. 47 CFR Part 15 C Requirements............................................................................................ 10 5.1 DUTY CYCLE....................................................................................................................... 10 5.1.1 LIMIT ................................................................................................................................. 10 5.1.2Test Configuration .............................................................................................................. 10 5.1.3TEST PROCEDURE .......................................................................................................... 10 5.2.1 Definition ........................................................................................................................... 13 5.2.2 Test Configuration.............................................................................................................. 14 5.2.3 Test Description ................................................................................................................. 15 5.2.4 Test Result......................................................................................................................... 15 5.3 20dB Bandwidth ................................................................................................................... 18 5.3.1 Requirement...................................................................................................................... 18 5.3.2 Test Description ................................................................................................................. 18 5.2.3 Test Result .....................................................................................................................18 5.4 Transmission Cease Time ....................................................................................................19 5.4.1 Requirement...................................................................................................................... 19 5.4.2 Test Description ................................................................................................................. 19 5.4.3 Test Result......................................................................................................................... 19 5.5 Antenna Requirement........................................................................................................... 21 5.5.1 Definition ........................................................................................................................... 21 5.5.2 Evaluation Criteria ............................................................................................................. 21 5.5.3 Evaluation Results............................................................................................................. 21 APPENDIX 1 .............................................................................................................................. 22 PHOTOGRAPHS OF TEST SETUP........................................................................................... 22 FCC ID: WEC-1503 Report No.: MTE/DYY/A15080988 Page 3 of 21 1.VERIFICATION OF CONFO…
Text truncated - open the document above for the full version.
FCC ID: WEC-1503 Model No.: TX07 CONDUCTED EMISSION TEST SETUP RE TEST SETUP FCC ID: WEC-1503 Model No.: TX07 RE TEST SETUP
No.5, 2nd Langshan Road, North District · Shenzhen, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 433.92 MHz - 433.92 MHz | - |

Professional weather station
Equipment Class
DTS - Digital Transmission System
Wireless Charging Pad
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzOutdoor Remote Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Bluetooth Smart Thermometer
Equipment Class
DTS - Digital Transmission System
MINI KEY FINDER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter