FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. elero GmbH Antriebstechnik/
  3. YBU2826X09X

YBU2826X09XLow power transceiver for screen market

elero GmbH Antriebstechnik
Low power transceiver for screen market - FCC ID YBU2826X09X - elero GmbH Antriebstechnik
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Jan 25, 2016
Application Purpose
Original Equipment
Date of Application
Jan 24, 2016
Equipment Note
Low power transceiver for screen market
Frequency Range
918.30000000 - 918.30000000
Company
elero GmbH Antriebstechnik
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

182020002_EN_0715 Operating instructions (translation) TempoTel 2 867/868/915 MHz 28265.0002, 28266.0002, 28267.0002, 28265.0902, 28266.0902, 28267.0902 Ⓒ elero GmbH 2 | EN Ⓒ elero GmbHEN | 3 Contents Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety instructions for radio operation . . . . . . . . . . . 5 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Scope of supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mounting of wall bracket . . . . . . . . . . . . . . . . . . . . . . 7 Description of the device . . . . . . . . . . . . . . . . . . . . . . 8 Explanation of functions . . . . . . . . . . . . . . . . . . . . . . . 9 Bidirectional radio system . . . . . . . . . . . . . . . . . . . . . 9 Unidirectional radio system . . . . . . . . . . . . . . . . . . . . 9 Initial operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Factory settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Menu structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Menu mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 DATE / TIME menu . . . . . . . . . . . . . . . . . . . . . . . . 17 PROGRAM menu . . . . . . . . . . . . . . . . . . . . . . . . . . 18 ADMINISTRATION menu . . . . . . . . . . . . . . . . . . . . 19 SETTINGS Menu . . . . . . . . . . . . . . . . . . . . . . . . . . 20 FUNCTION menu . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Programming the transmitter . . . . . . . . . . . . . . . . . 26 Programming additional transmitters . . . . . . . . . . . 27 Synchronized programming mode . . . . . . . . . . . . . 28 Stopping programming mode (bidirectional) in the transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Approaching limit positions of roller shutter / awning / Venetian blind . . . . . . . . . . 29 Operation of the transmitter using Combio JA Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Deleting positions/deleting transmitters . . . . . . . . . 32 Replacing the battery . . . . . . . . . . . . . . . . . . . . . . . . 33 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Towns for the selection . . . . . . . . . . . . . . . . . . . . . . 34 EC declaration of conformity . . . . . . . . . . . . . . . . . 35 Certifi cation FCC / IC . . . . . . . . . . . . . . . . . . . . . . . . 35 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Manufacturer's address . . . . . . . . . . . . . . . . . . . . . . 38 Disposal / notes on environmental protection . . . . . . . . . . . . 38 ContentsContents Ⓒ elero GmbH 4 | EN Ⓒ elero GmbHEN | 5 Safety instructions Observance of these instructions is a precondition for safe and fault-free operation and for the product performing as intended. • The operator/user shall have read the instructions fully and understand them. • The operator shall ensure that the instructions are available to the user in a legible form. • The operator shall ensure that all safety measures are observed and complied with. • The following safety and installation instructions relate to the device and not to its accessories or the drive. CAUTION! Failure to observe these instructions may lead to injury" Observe all safety instructions. • Never install or use damaged products. • Only use unmodifi ed and compatible original parts. • If the device is opened without permission or used in an improper manner, or if it is incorrectly installed or operated, there is a risk of damage to persons and property. • The unit contains small parts which can be swallowed. Transport • The device may not be used should you have received the device damaged, despite proper packaging. Complain about any damage to the transport company immediately. Installation • Observe all regulations for installation. Operation • Use only in dry rooms. • It must be possible to observe the equipment while it is in operation if the equipment is controlled by one or more transmitters. • Keep control systems out of the reach of children and the disabled. • Dispose of used batteries properly. Safety instructions for radio operation Observe all safety instructions for radio operation. Only use radio systems which are approved and can be operated without interference. • Radio systems must not be operated in areas where there is an increased risk of interference (e.g. hospitals, airports). • Remote control is permitted only for devices and equipment for which a malfunction of the transmitter or receiver does not give rise to a hazard to persons, animals or objects or where this safety risk is covered by other safety equipment. • The operator has no protection whatsoever against interference by other telecommunication installations and local terminals (e.g. also from radio installations which are operated properly in the same frequency range). • The range of the radio signal is limited by the government and the structural conditions. Safety instructionsSafety instructions for radio operation Ⓒ elero GmbH 6 | EN Ⓒ elero GmbHEN | 7 Intended use The TempoTel 2 is a multi-channel transmitter. This can be used unidirectionally (compatible with the existing ProLine program) or bidirectionally. The hand-held transmitter should only be used for controlling roller shutters, Venetian blinds and sun protection systems which are fi tted with elero radio receivers. Other uses or use going beyond this is considered to be contrary to the intended use. The handheld transmitter is referred to in these instructions as the “device”. Exclusion of liability elero GmbH accepts no liability for injury, damage or fi nancial…

Text truncated - open the document above for the full version.

Block Diagram

1 1 2 2 3 3 4 4 DD CC BB AA 01 Part No.: Name: Drawn by: COJ Rev.: Page: / 1Item: G:\EW\Mitarbeiter\Conzelmannj\Test_block\PCB_Project_block\TempoTel_Blockdiagramm.SchDoc LP.-No.: Blockdiagramm 23.371.5303 TempoTel 915 MHZ 28.265.0906 1 - + - + RTCDisplay SwitchμC Oscillator 4 MHz Batterie 3V Radio Transmitter 915,3 MHz FM Oscillator 26 MHz Antenna Blockdiagramm TempoTel 915 MHz Backup 36,768 KHz LED 2 MHz (SPI) 100KHz (I2C) 2 MHz (SPI) PI01 CO PI01 PI02 PI01 PI02 PI0M PI0P PI0M PI0PPI0P PI0M PI02 PI01

Cover Letter(s)

020415 – 08 Request for Confidentiality Date: _15 th September 2015_______ Subject: Confidentiality Request for: ______ YBU2826X09X ______ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 6.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 2 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* 3 User’s Manual ______elero GmbH Antriebstechnik ______ has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___180___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By: ________________ ___Mr. Karsten FEss___________ (Signature/Title 3 ) (Print name) 2 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section V regarding EXCEPTIONAL CIRCUMSTANCES. As of the October 2014 version of this document, TCB’s can not authorize these requests. The applicant should petition the FCC by submitting an inquiry as directed. A copy of this inquiry and the FCC’s response must be provided with the application. 3 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.

External Photos

FCC ID: YBU2826X09X Elero – Model: TEMPOTEL External Photos

ID Label/Location Info

FCC ID: YBU2826X09X Elero – Model: TEMPOTEL Label

Internal Photos

FCC ID: YBU2826X09X Elero – Model: TEMPOTEL Internal Photos

Test Report

FCC test report Notice: The result of tests and checks reported in this Test Report refer exclusively to the samples tested and described in the Report itself. This report shall not be reproduced partially or in its entirely without written approval of Nice S.p.A. Report nr. 212111FCC15 page 1 / 48 date: 11 January 2016 Nice S.p.A. Oderzo TV Italia tel. +39.0422.853838 www.niceforyou.com Test report nr. 212111FCC15 Measurements performed in accordance with: FCC Rules: code of Federal Regulations (CFR) no. 47 PART 15 – RADIO FREQUENCY DEVICES Product: Transceiver Tested model: TempoTel 2 FCC ID YBU2826X09X Applicant: elero gmbh Antriebstechnik Linsenhofer Str. 59-63 D-72660 Beuren Manufacturer: elero gmbh Antriebstechnik Linsenhofer Str. 59-63 D-72660 Beuren Trademark: elero Testing Laboratory Nice S.p.A. Via Pezza Alta, 13 I-31046 Rustignè di Oderzo (TV) Registration number: 771316 Date of receipt sample: 10 th March 2015 Testing date: 16 th March – 07 th April 2015 14 th September – 15 th September 2015 Issue date: 14 January 2016 Tested by: L. Pastres Checked by: E. Campion FCC test report Report nr. 212111FCC15 page 2 / 48 date: 11 January 2016 Nice S.p.A. Oderzo TV Italia tel. +39.0422.853838 www.niceforyou.com Contents Contents ............................................................................................................................. 2 1 General Description of Equipment under Test ............................................................. 3 1.1 Applicant .................................................................................................................... 3 1.2 Manufacturer .............................................................................................................. 3 1.3 Equipment classification ............................................................................................. 3 1.4 Basic Description of equipment under test ................................................................. 4 1.5 Feature of equipment under test ................................................................................ 5 2 Test configuration of equipment under test ................................................................. 6 2.1 Environmental conditions ........................................................................................... 6 2.2 Description of support equipment............................................................................... 6 2.3 Interface identification and connection diagram of test system .................................. 7 3 Operation of equipment under test ............................................................................... 8 3.1 Operating test conditions ........................................................................................... 8 4 Tests identification and result ....................................................................................... 9 4.1 Methods of measurement .......................................................................................... 9 4.2 Frequency range investigated .................................................................................... 9 5 Tests .............................................................................................................................. 10 5.1 Antenna requirements .............................................................................................. 10 5.2 Conduced emission .................................................................................................. 11 5.3 Radiated emission .................................................................................................... 12 5.4 Timing of the transmitter .......................................................................................... 19 5.5 Transmit behaviour after releasing the TX-button .................................................... 23 5.6 Radiated output power ............................................................................................. 25 5.8 Compliance with the limit of FCC ............................................................................. 31 5.9 Spurious emission - radiated .................................................................................... 32 5.10 Occuped bandwith ................................................................................................... 34 6 Measurement and Test Equipment instrumentation.................................................. 37 7 Photographic Documentation ...................................................................................... 41 8.1 EUT Identification ..................................................................................................... 41 8.2 Test Set-up .............................................................................................................. 44 Annex 1 ............................................................................................................................. 47 Annex 2 ............................................................................................................................. 48 FCC test report Report nr. 212111FCC15 page 3 / 48 date: 11 January 2016 Nice S.p.A. Oderzo TV Italia tel. +39.0422.853838 www.niceforyou.com 1 General Description of Equipment under Test 1.1 Applicant Name: elero gmbh Antriebstechnik Address: Linsenhofer Str. 65 D-72660 Beuren Country: GERMANY 1.2 Manufacturer Name: elero gmbh Antriebstechnik Address: Linsenhofer Str. 65 D-72660 Beuren Country: GERMANY 1.3 Equipment classification According to definition 15.3 (o) is a intentional Radiator operating within the Frequency: 915.3MHz and 918.3MHz. so it shall fulfil provisions of 47CFR Part 15 Subpart C – international radiators – and Section 15.209. According to definition 15.3 (z) is a unintentional Radiator: So it shall fulfil provisions of 47CFR Part 15 Subpart B – Unintentional radiator and section 15.231. FCC test report Repor…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: YBU2826X09X Elero – Model: TEMPOTEL Radiated Measurements Test Set-up

Contact Information

Applicant

Matthias Henschel(Dr.)
[email protected]+49-7022-4003-104Fax: +49-7022-4003-390

Test Firm

NICE S.p.A.Enrico Campion
[email protected]390422853838Fax: 00390422853585

Technical Specifications

#Rule PartsFrequency RangePower Output
215.231918.3 MHz - 918.3 MHz-
Confidentiality
Long Term

Other Applications from elero GmbH Antriebstechnik

Low power transceiver for screen market - FCC ID YBU2871X09X - elero GmbH Antriebstechnik
YBU2871X09X

Low power transceiver for screen market

Oct 22, 2015

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Tubular motors with electronic limit switch with transceiver at 915MHz - FCC ID YBURT915S - elero GmbH Antriebstechnik
YBURT915S

Tubular motors with electronic limit switch with transceiver at 915MHz

Sep 29, 2013

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Tubular Motor with Electronic Limit Switch - FCC ID YBURT915 - elero GmbH Antriebstechnik
YBURT915

Tubular Motor with Electronic Limit Switch

Aug 08, 2013

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
RC System for rolling shutters / awnings and venetian blinds - FCC ID YBU282XX0901 - elero GmbH Antriebstechnik
YBU282XX0901

RC System for rolling shutters / awnings and venetian blinds

Jun 09, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RC System for rolling shutters / awnings and venetian blinds - FCC ID YBU285XX0901 - elero GmbH Antriebstechnik
YBU285XX0901

RC System for rolling shutters / awnings and venetian blinds

Jun 08, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter