FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN TENDA TECHNOLOGY CO., LTD./
  3. V7TU11V11

V7TU11V11AX900 Wi-Fi 6 Wireless USB Adapter

SHENZHEN TENDA TECHNOLOGY CO., LTD.
AX900 Wi-Fi 6 Wireless USB Adapter - FCC ID V7TU11V11 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Mar 27, 2026
Application Purpose
Original Equipment
Equipment Note
AX900 Wi-Fi 6 Wireless USB Adapter
Frequency Range
5180.00000000 - 5240.00000000
Company
SHENZHEN TENDA TECHNOLOGY CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

BT/BLE:2402-2480MHz

RF Exposure Info

Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 62 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 63 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 64 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 65 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 66 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 67 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 68 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 69 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 70 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 71 of 119 Version 3.0

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B-TSP Page 1 of 4 TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B-TSP Page 2 of 4 Radiated Emissions View (Below 30MHz) Radiated Emissions View (Below 1 GHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B-TSP Page 3 of 4 Radiated Emissions View (1-18 GHz) Radiated Emissions View (18-40 GHz) Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B-TSP Page 4 of 4 Close-up View

Test Report

Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 151 of 236 Version 4.1 7-18GHz_Vertical_Average_5GWiFi_B1_AX20_5200MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 152 of 236 Version 4.1 1-7GHz_Horizontal_5GWiFi_B1_AX40_5230MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 153 of 236 Version 4.1 1-7GHz_Vertical_5GWiFi_B1_AX40_5230MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 154 of 236 Version 4.1 7-18GHz_Horizontal_Peak_5GWiFi_B1_AX40_5230MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 155 of 236 Version 4.1 7-18GHz_Horizontal_Average_5GWiFi_B1_AX40_5230MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 156 of 236 Version 4.1 7-18GHz_Vertical_Peak_5GWiFi_B1_AX40_5230MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 157 of 236 Version 4.1 7-18GHz_Vertical_Average_5GWiFi_B1_AX40_5230MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 158 of 236 Version 4.1 1-7GHz_Horizontal_5GWiFi_B1_AX80_5210MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 159 of 236 Version 4.1 1-7GHz_Vertical_5GWiFi_B1_AX80_5210MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 160 of 236 Version 4.1 7-18GHz_Horizontal_Peak_5GWiFi_B1_AX80_5210MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 161 of 236 Version 4.1 7-18GHz_Horizontal_Average_5GWiFi_B1_AX80_5210MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 162 of 236 Version 4.1 7-18GHz_Vertical_Peak_5GWiFi_B1_AX80_5210MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 163 of 236 Version 4.1 7-18GHz_Vertical_Average_5GWiFi_B1_AX80_5210MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 164 of 236 Version 4.1 1-7GHz_Horizontal_5GWiFi_B4_A_5825MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 165 of 236 Version 4.1 1-7GHz_Vertical_5GWiFi_B4_A_5825MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 166 of 236 Version 4.1 7-18GHz_Horizontal_Peak_5GWiFi_B4_A_5825MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 167 of 236 Version 4.1 7-18GHz_Horizontal_Average_5GWiFi_B4_A_5825MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 168 of 236 Version 4.1 7-18GHz_Vertical_Peak_5GWiFi_B4_A_5825MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 169 of 236 Version 4.1 7-18GHz_Vertical_Average_5GWiFi_B4_A_5825MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 170 of 236 Version 4.1 1-7GHz_Horizontal_5GWiFi_B4_AC20_5785MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 171 of 236 Version 4.1 1-7GHz_Vertical_5GWiFi_B4_AC20_5785MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 172 of 236 Version 4.1 7-18GHz_Horizontal_Peak_5GWiFi_B4_AC20_5785MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 173 of 236 Version 4.1 7-18GHz_Horizontal_Average_5GWiFi_B4_AC20_5785MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 174 of 236 Version 4.1 7-18GHz_Vertical_Peak_5GWiFi_B4_AC20_5785MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 175 of 236 Version 4.1 7-18GHz_Vertical_Average_5GWiFi_B4_AC20_5785MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 176 of 236 Version 4.1 1-7GHz_Horizontal_5GWiFi_B4_AC40_5755MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 177 of 236 Version 4.1 1-7GHz_ Vertical_5GWiFi_B4_AC40_5755MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 178 of 236 Version 4.1 7-18GHz_Horizontal_Peak_5GWiFi_B4_AC40_5755MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 179 of 236 Version 4.1 7-18GHz_Horizontal_Average_5GWiFi_B4_AC40_5755MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 180 of 236 Version 4.1 7-18GHz_Vertical_Peak_5GWiFi_B4_AC40_5755MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 181 of 236 Version 4.1 7-18GHz_Vertical_Average_5GWiFi_B4_AC40_5755MHz Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 182 of 236 Version 4.1 1-7GHz_Horizontal_5GWiFi_B4_AC80_5775MHz Fundamental Test with Band Rejection Filter Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 183 of 236 Version 4.1 1-7GHz_Vertical_5GWiFi_B4_AC80_5775MHz Fundamental Test with Band Rejection Filter Bay Area Complianc…

Text truncated - open the document above for the full version.

Test Report

Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018 Fax: +86-755-33320008 www.baclcorp.com.cn TR-EM-RF015 Page 1 of 236 Version 4.1 TEST REPORT Applicant Name:SHENZHEN TENDA TECHNOLOGY CO., LTD. Address:6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Report Number:2601P07161E-RF-00B FCC ID:V7TU11V11 Test Standard (s) FCC PART 15.407 Sample Description Product Type:AX900 Wi-Fi 6 Wireless USB Adapter Model No.:U11 Multiple Model(s) No.:N/A Trade Mark:Tenda Date Received:2026-01-21 Issue Date:2026-03-18 Test Result:Pass ▲ ▲ In the configuration tested, the EUT complied with the standards above. Prepared and Checked By:Approved By: Ekko WuNancy Wang RF EngineerRF Supervisor Bay Area Compliance Laboratories Corp. (Shenzhen) Report No.: 2601P07161E-RF-00B TR-EM-RF015 Page 2 of 236 Version 4.1 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ..........................................................................................................................3 GENERAL INFORMATION ........................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)......................................................................................4 OBJECTIVE ....................................................................................................................................................................4 TEST METHODOLOGY....................................................................................................................................................4 MEASUREMENT UNCERTAINTY .....................................................................................................................................5 TEST FACILITY ..............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ...........................................................................................................................6 SUMMARY OF TEST RESULTS ..............................................................................................................................10 TEST EQUIPMENT LIST ..........................................................................................................................................11 REQUIREMENTS AND TEST PROCEDURES ......................................................................................................13 AC LINE CONDUCTED EMISSIONS...............................................................................................................................13 UNDESIRABLE EMISSION .............................................................................................................................................15 EMISSION BANDWIDTH & 99% OCCUPIED BANDWIDTH .............................................................................................19 CONDUCTED TRANSMITTER OUTPUT POWER..............................................................................................................21 POWER SPECTRAL DENSITY ........................................................................................................................................22 DUTY CYCLE ...............................................................................................................................................................23 ANTENNA REQUIREMENT .....................................................................................................................................24 TEST DATA AND RESULTS .....................................................................................................................................25 CONDUCTED EMISSIONS..............................................................................................................................................25 UNDESIRABLE EMISSION .............................................................................................................................................28 EMISSION BANDWIDTH .............................................................................................................................................208 99% OCCUPIED BANDWIDTH ....................................................................................................................................215 MAXIMUM CONDUCTED OUTPUT POWER .................................................................................................................222 POWER SPECTRAL DENSITY ......................................................................................................................................224 DUTY CYCLE .............................................................................................................................................................231 RF EXPOSURE EVALUA…

Text truncated - open the document above for the full version.

Test Report

ANTENNA TEST REPORT Page 1 ANTENNA TEST REPORT Manufacture:SHENZHEN TENDA TECHNOLOGY CO.,LTD. ADD: 6- 8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Product Name U11 5G Antenna Product picture ANTENNA TEST REPORT Page 2 Electrical performance test results Number Inspection item unit Performance requirements Inspection result 1 Frequency rangeMHz 2400 -2483 2400 -2483 OK 2 Gain dBi 1.5 2412 1.4 OK 2450 1.0 OK 2483 0.6 OK 4 Return loss dB ≤-6 2400 -9 OK 2450 -11 OK 2483 -10 OK Number Inspection item unit Performance requirements Inspection result 1 Frequency rangeMHz 5150 -5850 5150 -5850 OK 2.4G Antenna ANTENNA TEST REPORT Page 3 2 gain dBi 0.5 5150 0.5 OK 5500 0.4 OK 5850 0.3 OK 4 Return loss dB ≤-6 5150 -21 OK 5500 -14 OK 5850 -11 OK Frequency-MHz 2400-2483/5150-5850 ANTENNA TEST REPORT Page 4 3D radiation pattern(2.4G) 2D radiation pattern(2.4G) V-plane 2D radiation pattern(2.4G) H-plane 3D radiation pattern(5G) ANTENNA TEST REPORT Page 5 2D radiation pattern(5.5G) V-plane 2D radiation pattern(5.5G) H-plane

RF Exposure Info

Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 106 of 119 Version 3.0 5. Test Plot & System Validation Data: Dipole, 5250MHz, 1374 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 107 of 119 Version 3.0 Dipole, 5600MHz, 1374 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 108 of 119 Version 3.0 Dipole, 5800MHz, 1374 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 109 of 119 Version 3.0 System Performance 5250 MHz Head DUT: Dipole D5GHz; Type: D5GHzV2; Serial: 1374 Communication System: UID 0, CW (0); Frequency: 5250 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5250 MHz; σ = 4.65 S/m; ε r = 34.729; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: • Probe: EX3DV4 - SN7382; ConvF(5.62, 5.62, 5.62) @ 5250 MHz; • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1325; Calibrated: 9/27/2023 • Phantom: SAM-Twin V8.0 P1aP2a; Type: QD 000 P41 AA ; Serial: 1962 • Measurement SW: DASY52, Version 52.10 (2); Configuration/Head 5250MHz Pin=100mW/Area Scan (7x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 17.7 W/kg Configuration/Head 5250MHz Pin=100mW/Zoom Scan (8x8x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 44.86 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 28.0 W/kg SAR(1 g) = 8.14 W/kg; SAR(10 g) = 2.41 W/kg Maximum value of SAR (measured) = 18.5 W/kg 0 dB = 18.5 W/kg = 12.67 dBW/kg Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 110 of 119 Version 3.0 System Performance 5600 MHz Head DUT: Dipole D5GHz; Type: D5GHzV2; Serial: 1374 Communication System: UID 0, CW (0); Frequency: 5600 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5600 MHz; σ = 5.099 S/m; ε r = 35.785; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: • Probe: EX3DV4 - SN7382; ConvF(5.1, 5.1, 5.1) @ 5600 MHz; • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1325; Calibrated: 9/27/2023 • Phantom: SAM-Twin V8.0 P1aP2a; Type: QD 000 P41 AA ; Serial: 1962 • Measurement SW: DASY52, Version 52.10 (2); Configuration/Head 5600MHz Pin=100mW/Area Scan (7x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 18.9 W/kg Configuration/Head 5600MHz Pin=100mW/Zoom Scan (8x8x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 42.74 V/m; Power Drift = -0.12 dB Peak SAR (extrapolated) = 28.6 W/kg SAR(1 g) = 7.68 W/kg; SAR(10 g) = 2.23 W/kg Maximum value of SAR (measured) = 17.7 W/kg 0 dB = 17.7 W/kg = 12.48 dBW/kg Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 111 of 119 Version 3.0 System Performance 5800 MHz Head DUT: Dipole D5GHz; Type: D5GHzV2; Serial: 1374 Communication System: UID 0, CW (0); Frequency: 5800 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5800 MHz; σ = 5.233 S/m; ε r = 34.327; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: • Probe: EX3DV4 - SN7382; ConvF(5.08, 5.08, 5.08) @ 5800 MHz; • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electronics: DAE4 Sn1325; Calibrated: 9/27/2023 • Phantom: SAM-Twin V8.0 P1aP2a; Type: QD 000 P41 AA ; Serial: 1962 • Measurement SW: DASY52, Version 52.10 (2); Configuration/Head 5800MHz Pin=100mW/Area Scan (7x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 19.6 W/kg Configuration/Head 5800MHz Pin=100mW/Zoom Scan (8x8x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 41.74 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 31.8 W/kg SAR(1 g) = 7.97 W/kg; SAR(10 g) = 2.32 W/kg Maximum value of SAR (measured) = 19.2 W/kg 0 dB = 19.2 W/kg = 12.83 dBW/kg Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 112 of 119 Version 3.0 Performance Qualification Report For 5GHz SAR Dipole-2 Equipment Details: Description: Dipole Manufacturer: Speag Model Number: D5GHzV2 Serial Number: 1374 Calibration Date: 2025/03/26 Calibration and Checked By: Approved By: Bob Lu Luke Jiang 1. Equipment List & Calibration Information: Equipment Model S/N Calibration Date Calibration Due Date DASY5 Test Software DASY52 52.10.2 N/A NCR NCR DASY6 Measurement Server DASY6 6.0.31 N/A NCR NCR Data Acquisition Electronics DAE4 1325 2024/10/08 2025/10/07 Dosimetric E-field Probes EX3DV4 7896 2024/11/07 2025/11/06 Mounting Device MD4HHTV5 SD 000 H01 KA NCR NCR SAM Twin Phantom SAM-Twin V8.0 1962 NCR NCR Simulated Tissue Liquid Head HBBL600-10000V62200808-2 Each Time SAM Twin Phantom SAM-Twin V8.0 1962 NCR NCR Network Analyzer E5071C SER MY46519680 2024/05/21 2025/05/20 Network Analyzer Calibration Kit 50 Ω 51026 NCR NCR MXG Analog Signal Generator N5181A MY48180408 2024/12/04 2025/12/03 Microwave peak power sensor MA24418A 12622 NCR NCR USB wideband power sensor U2021XA MY52350001 2024/05/21 2025/05/20 20dBAttenuator N/A N/A NCR NCR Directional Coupler 855673 3307 NCR NCR 2. Standard Requirements: Referring to KDB 865664 D01 3.3.2, for dipole calibration, longer calibration intervals of up to three years may be considered when it is demonstrated that the SAR target, impedance and return loss of a dipole have remain stable according to the following requirements: 1) When the measured SAR does not deviates from the calibrated SAR value by more than 10%. 2) When the most recent return-loss result, measured at least annually, does not deviate by more than 20% from the previous measurement or meeting the required 20 dB minimum return-loss requirement. 3) When the most recent measurement of the real or imaginary parts of the impedance, measured at least annually, does not deviate by more than 5 Ω from the previous measurement. Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 113 of 119 Version 3.0 3. Environmental Conditions:…

Text truncated - open the document above for the full version.

RF Exposure Info

Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 78 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 79 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 80 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 81 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 82 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 83 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 84 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 85 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 86 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 87 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 88 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 89 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 90 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 91 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 92 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 93 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 94 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 95 of 119 Version 3.0 APPENDIX D RETURN LOSS&IMPEDANCE MEASUREMENT Performance Qualification Report For 2450MHz SAR Dipole-1 Equipment Details: Description: Dipole Manufacturer: Speag Model Number: D2450V3 Serial Number: 1103 Calibration Date: 2024/03/27 Calibration and Checked By: Approved By: Bob Lu Luke Jiang 1. Equipment List & Calibration Information: Equipment Model S/N Calibration Date Calibration Due Date DASY5 Test Software DASY52 52.10.2 N/A NCR NCR DASY6 Measurement Server DASY6 6.0.31 N/A NCR NCR Data Acquisition Electronics DAE4 1325 2023/09/27 2024/09/26 E-Field Probe EX3DV4 7382 2023/09/27 2024/09/26 Mounting Device MD4HHTV5 SD 000 H01 KA NCR NCR SAM Twin Phantom SAM-Twin V8.0 1962 NCR NCR Simulated Tissue Liquid Head HBBL600-10000V62200808-2 Each Time SAM Twin Phantom SAM-Twin V8.0 1962 NCR NCR Network Analyzer E5071C SER MY46519680 2023/06/08 2024/06/07 Network Analyzer Calibration Kit 50 Ω 51026 NCR NCR MXG Analog Signal Generator N5181A MY48180408 2024/01/16 2025/01/15 Microwave peak power sensor MA24418A 12622 NCR NCR USB wideband power sensor U2021XA MY52350001 2023/06/08 2024/06/07 20dBAttenuator N/A N/A NCR NCR Directional Coupler 855673 3307 NCR NCR 2. Standard Requirements: Referring to KDB 865664 D01 3.3.2, for dipole calibration, longer calibration intervals of up to three years may be considered when it is demonstrated that the SAR target, impedance and return loss of a dipole have remain stable according to the following requirements: 1) When the measured SAR does not deviates from the calibrated SAR value by more than 10%. 2) When the most recent return-loss result, measured at least annually, does not deviate by more than 20% from the previous measurement or meeting the required 20 dB minimum return-loss requirement. 3) When the most recent measurement of the real or imaginary parts of the impedance, measured at least annually, does not deviate by more than 5 Ω from the previous measurement. Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 96 of 119 Version 3.0 3. Environmental Conditions: TSL Temperature: 18.7 ~ 19.6°C Ambient Temperature: 21 ~ 22.7°C Relative Humidity:43 ~ 48% ATM Pressure:101.3 kPa Test Date:2024/03/27 4. Test Results: Return Loss & Impedance Measurement Results: Frequency (MHz) Simulated Liquid Parameter Measured Value Target Value Deviation Reference Range Results 2450 Head Return Loss 25.308 dB 24.161 dB 4.747 % ±20%; ≥20dB Pass Real Impedance 56.592 Ω 53.467 Ω 3.125 Ω ≤ 5 Ω Pass Imaginary Impedance 0.829 Ω 5.400 Ω -4.571 Ω ≤ 5 Ω Pass Liquid Verification Results: Frequency (MHz) Liquid Type Liquid Parameter Target Value Delta (%) Tolerance (%) ε r Ơ (S/m) ε r Ơ (S/m) Δε r ΔƠ 2450 Simulated Tissue Liquid Head 38.866 1.794 39.20 1.80 -0.85 -0.33 ±5 System Accuracy Check Results: Frequency Band (MHz) Liquid Type Input Power (mW) Measured SAR (W/kg) Normalized to 1W (W/kg) Target Value (W/Kg) Delta (%) Tolerance (%) 2450 Head 100 1g 5.04 50.4 51.7 -2.515 ±10 10g 2.41 24.1 24.2 -0.413 ±10 Note: 1. Return Loss Deviation = (Measured-Target)/Target×100% 2. The target values above please refer to 2450MHz dipole calibration certificate (Certificate No .: D2450V2-1103_Mar23), which was issue by SPEAG. Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 97 of 119 Version 3.0 5. Test Plot & System Validation Data: Dipole, 2450MHz, 1103 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 98 of 119 Version 3.0 System Performance 2450 MHz Head DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 1103 Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2450 MHz; σ = 1.794 S/m; ε r = 38.866; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: • Probe: EX3DV4 - SN7382; ConvF(7.89, 7.89, 7.89) @ 2450 MHz; • Sensor-Surface: 1.4mm (Mechanical Surface Detection) • Electr…

Text truncated - open the document above for the full version.

RF Exposure Info

Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 72 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 73 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 74 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 75 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 76 of 119 Version 3.0 Bay Area Compliance Laboratories Corp.(Shenzhen) Report No.: 2601P07161E-SA TR-EM-SA005 Page 77 of 119 Version 3.0

Attestation Statements

       !"# $%# &## "# '"(')( *  ' # ++, -++,-+-.#/-++,-+-- 0#')(1( #)   23345363789:4334;  #(,,,  &  <<=> >  << >>  %('*#(' # ?#%#(' '?'"'  -@+ #A# <'"&# %0B'#<,@  #'<##0  %C%)( D.E''E'""=F #C(0= >G-=G H0#A(' !C%C"('"C%)( $"%CC("+ E''I+++,+<*+-,+++<* JKLMNNOPQLKPQRKPOLKPOSRKPOSJKPOTLKPOTRKPOTJKUVWXYZ[\]^N_PL_[\`abcde[fPRghi hij,@ E''I,@,,@,<*,Bk!k ,k @k#/,k#/@0"j,#/0 $ "%CC("H%&=# " l("%CC(C#('#&=(H% )(' "B# "# 0"#"'"#B (%"B$0# %H#)(%' ("H(#( %"#" )#C#B''($(#)('?#('(  ' )$  h' (#0  % '( !'  

RF Exposure Info

Note: The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP or any agency of the U.S. Government. This report may contain data that are not covered by the NVLAP accreditation and are marked with an asterisk “▼”. Bay Area Compliance Laboratories Corp. (Shenzhen) 5F(B-West) , 6F, 7F, the 3rd Phase of Wan Li Industrial Building D, Shihua Rd, FuTian Free Trade Zone, Shenzhen, China Tel: +86-755-33320018Fax: +86-755-33320008www.baclcorp.com.cn TR-EM-SA005 Page 1 of 119 Version 3.0 TEST REPORT Applicant Name: SHENZHEN TENDA TECHNOLOGY CO., LTD. Address: 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Report Number: 2601P07161E-SA FCC ID: V7TU11V11 Test Standard (s) FCC 47 CFR part 2.1093 Sample Description Product Name: AX900 Wi-Fi 6 Wireless USB Adapter Model …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shen Yue(Engineer)
[email protected]Fax: 866-755-27657178

Technical Contact

Tenda Technology, IncSunny Chang
[email protected]

530 Technology Drive suite100 · Irvine, California, 92618 · United States

Test Firm

Bay Area Compliance Laboratories Corp (Shenzhen)Nana Liu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz28.00 mW
215E5.75 GHz - 5.83 GHz14.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 5 mm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory transmission exposure condition is 0.98 W/kg.

Other Applications from SHENZHEN TENDA TECHNOLOGY CO., LTD.

AX1800 Wi-Fi 6 Dual-Band USB Adapter - FCC ID V7TU18V3 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TU18V3

AX1800 Wi-Fi 6 Dual-Band USB Adapter

Aug 26, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
AX3000 Dual-Band Gigabit Wi-Fi Range Extender, AX1800 Dual-Band Gigabit Wi-Fi Range Extender - FCC ID V7TA33V2 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TA33V2

AX3000 Dual-Band Gigabit Wi-Fi Range Extender, AX1800 Dual-Band Gigabit Wi-Fi Range Extender

Aug 25, 2026

Equipment Class

DTS - Digital Transmission System
6MP Dual-lens Linkage Wi-Fi Pan/Tilt Camera - FCC ID V7TCH9V2 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCH9V2

6MP Dual-lens Linkage Wi-Fi Pan/Tilt Camera

Jul 20, 2026

Equipment Class

DTS - Digital Transmission System
3MP Wi-Fi Pan/Tilt Camera - FCC ID V7TCH3V21 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCH3V21

3MP Wi-Fi Pan/Tilt Camera

Jul 14, 2026

Equipment Class

DTS - Digital Transmission System
3MP Security Pan/Tilt Camera - FCC ID V7TCP3P1 - SHENZHEN TENDA TECHNOLOGY CO., LTD.
V7TCP3P1

3MP Security Pan/Tilt Camera

Jun 30, 2026

Equipment Class

DTS - Digital Transmission System